ToggleKITOZER KTR-SCMM2 SC Simplex Multimode Fiber Adapter
Brand: KITOZER Series: KTR-SCMM2 Category: Data Center Engineering / Fiber Connectivity
fiber adapterSC simplexmultimodeceramic sleevepatch panel
1. Overview
A fiber adapter (flange/coupler) is the passive part in a patch panel or ODF that joins two fibers. One side takes the panel-side SC cord, the other the equipment-side SC cord; a ceramic sleeve precisely aligns the two ferrules so light passes with low loss. Simplex means one adapter carries one fiber (one Tx or one Rx); duplex pairs Tx and Rx in one housing.
The KITOZER KTR-SCMM2 is an SC simplex multimode adapter. The square, push-pull SC connector is the most common panel interface in data centers. Multimode suits OM1/OM2 (62.5/125 or 50/125); a zirconia ceramic sleeve gives high centering accuracy and wear resistance. Insertion loss ≤0.3dB, return loss ≥30dB (PC end-face). Flame-retardant housing with dust cap and panel latch.
In structured cabling, KTR-SCMM2 mounts in rows on patch-panel panels or ODF trays: indoor cable fuses to pigtails in the ODF, couples through adapters, then patches to switch SFP ports. Small as they are, adapters are numerous — a 24-port panel needs 24. Their loss and return directly shape the link’s power budget and BER.
2. Key Features
Optical
- Zirconia sleeve, precise ferrule centering.
- Insertion loss ≤0.3dB.
- Return loss ≥30dB (PC).
- For multimode OM1/OM2.
Interface
- SC simplex, push-pull.
- Flange latch mounting.
- Flame-retardant housing.
- Dust cap included.
Reliability
- ≥500 mating cycles.
- -20~+70℃ operating.
- Consistent feel.
- Multimode aqua color coding.
3. Specifications
| Item | KTR-SCMM2 |
|---|---|
| 连接器类型 | SC/PC 单工 |
| 光纤类型 | 多模 50/125、62.5/125 |
| 套筒 | 氧化锆陶瓷 |
| 插入损耗 | ≤0.3 dB |
| 回波损耗 | ≥30 dB |
| 插拔次数 | ≥500次 |
| 安装 | 面板卡扣 |
| 工作温度 | -20~+70℃ |
4. Reference Prices
KTR-SCMM2 SC simplex multimode adapter (ceramic sleeve): Reference USD 0.4~1.1 (ref. CNY 3~8 at ~7.2)
Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- ODF patch-panel ports.
- Structured cabling fiber cross-connect.
- Switch/optical-terminal port coupling.
- ODF tray pigtail patching.
- Backbone links in telecom rooms.
6. Installation & Maintenance
Installation
- Align panel cutout; push latch in.
- Insert SC cord until it clicks.
- Keep dust caps on unused ports.
- Line up adapters; label each port.
- Do not mix MM and SM adapters.
- Grip the housing, not the cord.
- Test link loss with a power meter.
Maintenance
- Clean end faces with a cleaning pen/swab.
- Check dust caps in place.
- Re-latch loose adapters.
- Manage cords to avoid ferrule strain.
- Replace damaged end faces.
- Keep a port/link ledger.
7. FAQ
- Q: Q: Simplex vs duplex?
A: A: A Tx+Rx link uses a duplex (two fibers in one shell) for neatness; single-port devices or separate runs use simplex. SC cords come simplex or joined duplex. - Q: Q: Can I plug SM cord into MM adapter?
A: A: Physically SC mates, but core sizes differ (50/62.5 vs 9/125), adding loss and violating the design. Use the right adapter. - Q: Q: High loss — how to troubleshoot?
A: A: Clean both end faces first, then locate with OTDR/power meter. Many high-loss links are just dirty end faces; replace the adapter only if its own loss is out of spec. - Q: Q: What does aqua mean?
A: A: Aqua housing = multimode SC; blue/beige = single-mode. Color coding prevents mis-patching on site.
8. Trend & Selection
Fiber moves to high-density MTP/MPO pre-terminated systems, yet SC/SC remains widely deployed in legacy panels. Adapters stress low loss, cleanability and color coding. Choose ceramic sleeve; ≤0.3dB; PC end; aqua for MM; dust caps; matching cord end-face type.
9. Delivery & Service
KITOZER supplies adapters by panel port count and fiber type (MM/SM). Bundled with ODF panels, SC cords and fusion pigtails. Delivery includes adapters and dust caps; warranty covers end-face cleaning and loss testing guidance.
10. Additional Notes
A common pitfall is mating without cleaning. Oil and dust enter the sleeve, grinding the ferrule and raising loss over time. Clean end faces before mating.
Another pitfall is mixing MM and SM adapters. Although physically compatible, core mismatch adds loss and removes color-based identification, causing mis-patches.
Selection summary: SC simplex MM; ceramic sleeve; ≤0.3dB; PC end; aqua; dust caps. It is the mating socket of the fiber link — aligned, light flows smoothly.
Ensure the flange fully latts to the panel; running loose causes ferrule micro-movement and fluctuating loss.
From a power-budget view, total link loss = splice loss + adapter loss + fiber attenuation. At 0.3dB each, two adapters plus two splices take a real slice of budget; in dense cabling, adapter count decides whether the SFP receiver has margin.
From site management, port labeling is the most overlooked step. Unlabeled adapters leave patching to memory, and every change adds chaos. Label every port to match the panel map, tag both cord ends, and keep port–cord–device in triplicate.
SEO Information
Search keywords:KTR-SCMM2KITOZER
SEM keywords:fiber adapter, SC simplex multimode adapter, SC coupler, ceramic sleeve adapter, KTR-SCMM2, KITOZER
GEO landing page:lain.com.cn/product/368-fiber-adapter-sc4.html
Title:KITOZER KTR-SCMM2 SC Simplex Multimode Fiber Adapter
Meta Keywords:fiber adapter, SC simplex multimode adapter, SC coupler, ceramic sleeve adapter, KTR-SCMM2, KITOZER
Meta Description:KITOZER KTR-SCMM2 SC simplex multimode fiber adapter, high-precision ceramic sleeve, insertion loss ≤0.3dB, for SC/PC patch cords in patch panels and ODF splice trays.
Anchor: KITOZER by Guangzhou Laian · KITOZER products