KITOZER
KITOZER

KITOZER SC duplex UPC OM4 adapter

KITOZER KTR-SCUPC13 Fiber Adapter / SC Duplex UPC OM4

Brand: KITOZER Series: KTR-SCUPC13 Category: Data Center Engineering / Fiber Adapter

fiber adapterSC duplexUPCOM4multimodeKTR-SCUPC13

1. Overview

KITOZER KTR-SCUPC13 is an SC duplex UPC OM4 fiber adapter (also called coupler or flange), a passive part for mating two fiber jumpers. It mounts on fiber patch panels, termination boxes or wall outlets: an SC plug inserts from each side for a low-loss optical connection. SC duplex integrates receive (Rx) and transmit (Tx) SC ports side by side, matching the dual-cord jumpers of traditional Gigabit/10G optical modules.

KTR-SCUPC13 uses UPC (Ultra Physical Contact) polished end faces and a zirconia ceramic sleeve. UPC spherical polishing gives good return loss (>=40 dB); the precision-bore sleeve aligns cores closely, keeping insertion loss low (<=0.2 dB). OM4 suits 50/125 um multimode fiber, supporting long-reach 10G and short-reach 40G, compatible with OM3/OM4 cords. The flame-retardant housing includes dust caps; panel snaps fit standard SC cutouts.

In data center low-voltage cabling, adapters are everywhere: dozens per patch panel, hundreds per room. Though cheap, their loss and return-loss metrics directly affect link quality: one poor adapter can raise errors on a whole 10G link. KTR-SCUPC13 is supplied in volume as a baseline passive part with consistency and field replaceability.

2. Key Features

SC duplex structure

  • Rx/Tx dual cores side by side.
  • Snap-in panel mounting.
  • Dust caps seal unused ports.

UPC ceramic end face

  • UPC spherical polish, return loss >=40 dB.
  • Zirconia sleeve with precision bore.
  • Insertion loss <=0.2 dB.

OM4 multimode compatible

  • Fits 50/125 um multimode fiber.
  • Compatible with OM3/OM4 cords and modules.
  • Supports 10G long, 40G short reach.

Flame-retardant & reliable

  • UL94 V-0 rated housing.
  • >=500 mating cycles.
  • Good batch consistency.

3. Specifications

Item KTR-SCUPC13-D KTR-SCUPC13-S(Simplex) KTR-SCUPC13-24(Distribution Frame)
Interface Type SCDuplex SCSimplex 24 PortsSCDuplex Panel
End Face Polishing UPC UPC UPC
Fiber Type OM4Multi Mode OM4Multi Mode OM4Multi Mode
Insertion Loss(dB) NotHighAt0.2 NotHighAt0.2 NotHighAt0.2
Return Loss(dB) NotLowAt40 NotLowAt40 NotLowAt40
SetCylinderMaterial Zirconia Ceramic Zirconia Ceramic Zirconia Ceramic
Insertion Life(Times) NotLowAt500 NotLowAt500 NotLowAt500
Flame Retardant Rating UL94 V-0 UL94 V-0 UL94 V-0

4. Reference Prices

KTR-SCUPC13-D SCDuplexUPC OM4Adapter(Ceramic Ferrule、Dust Cap): Reference USD 1~2 / unit (ref. CNY 5~12 at ~7.2)

KTR-SCUPC13-24 24 PortsSCDuplexOM4Distribution Frame(IncludingAdapter、Rack1U): Reference USD 42~81 / unit (ref. CNY 300~580 at ~7.2)

Reference only; by quantity with volume discounts. Sold individually or as a populated patch panel. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Fiber patch panel ports in data centers.
  • Gigabit/10G module jumper mating.
  • Fiber termination boxes in telecom rooms.
  • Wall fiber outlets in offices.
  • 10G Ethernet and storage fiber links.

6. Installation & Maintenance

Installation

  • Confirm standard SC duplex cutout.
  • Snap adapter into panel in the right orientation.
  • Remove dust cap; insert SC cord until click.
  • Keep dust caps on unused ports.
  • Test link loss with source and power meter.
  • Label port mapping.

Maintenance

  • Check dust caps are in place.
  • Plug/unplug by the connector, never pull the cord.
  • Clean dirty end faces with a fiber cleaner pen.
  • Replace adapters whose loss rises.
  • Dust patch panels periodically.

7. FAQ

  • Q: SC duplex or simplex?
    A: Use duplex where modules use dual cords (one Tx one Rx); simplex for single-fiber links. Traditional 10G modules use duplex.
  • Q: UPC vs APC?
    A: UPC is spherical polish, usually blue; APC is 8-degree angle, green, higher return loss. Multimode OM4 links generally use UPC.
  • Q: Does an OM4 adapter work with OM3 cords?
    A: Yes; the adapter is a passive mating part; OM3/OM4 multimode adapters are interchangeable; link grade is set by cords and modules.
  • Q: What loss is normal?
    A: Insertion loss <=0.2 dB is normal; over 0.3~0.5 dB means a dirty end face or worn sleeve — clean or replace.

8. Trend & Selection

Data centers move to 40G/100G and multimode upgrades OM3 to OM4/OM5, but SC duplex adapters remain the baseline mating parts, emphasizing low loss, consistency, flame retardance and cleanability. OM4 adapters support installed and new 10G cabling. Select by link grade (UPC), connector type (SC duplex) and fiber type (OM4); buy in volume for consistency and mating life; a populated panel is convenient.

9. Delivery & Service

KITOZER supplies SC duplex OM4 adapters in volume, pre-assembled on 24/48-port 1U/2U rack panels. We provide insertion-loss test reports. Delivery includes adapters, dust caps and panel snaps; populated panels include rack and cable management. Warranty covers adapters with abnormal loss.

10. Additional Notes

The most overlooked loss source is a dirty adapter end face. After a few mates, dust adds 0.3~0.5 dB per adapter, shrinking a link 3 dB margin to 1 dB and raising errors. After install, clean every port with a fiber cleaner — never judge by eye.

Another pitfall: saving money on cheap sleeves. A zirconia sleeve replaced by plastic or low-precision metal pushes insertion loss from 0.2 dB to over 0.5 dB; across dozens of ports the accumulated loss is large. Adapters are cheap, but the sleeve must be ceramic.

Selection summary: SC duplex for dual-core modules; UPC end faces for multimode OM4; ceramic sleeve for low loss; keep dust caps on; clean port by port after install; pre-assembled panels save labor. The adapter is the optical outlet — clean and aligned, and the signal runs steady.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top