KITOZER KTR-SPD12 Signal SPD (RS485/4-20mA Surge Protection)

KITOZER KTR-SPD12 Signal SPD (RS485/4-20mA Surge Protection)

Brand: KITOZER Series: KTR-SPD12 Category: Lightning Protection / Signal SPD

RS485/4-20mAUc=6VIn=5kA≤1ns responseDIN railKTR-SPD12

1. Overview

The KITOZER KTR-SPD12 is a surge protective device (SPD) dedicated to signal lines. It is installed in RS485 bus, 4-20 mA analog, DI/DO switch and digital pulse loops to prevent lightning or switching-surge overvoltage from damaging field instruments, PLC modules and acquisition equipment. Two-stage protection (GDT + TVS semiconductor), response ≤1 ns, low residual voltage.

KTR-SPD12 nominal discharge current In=5 kA (8/20 μs), max Imax=10 kA; rated voltage Uc=6 V (matches RS485/4-20 mA signal levels). Mounts on DIN35 rail in control cabinets, in series at the signal line front-end (protected-equipment side). Screw terminals, IN/OUT top-bottom, ground to the equipotential bar.

Typical uses: outdoor temp/humidity/pressure transmitter to PLC 4-20 mA signal protection; RS485 bus (daisy-chain) head and tail SPD; camera/access-control switch signal protection; mandatory SPD for sensor runs >50 m.

2. Key Features

Two-stage

  • GDT diverts high current.
  • TVS clamps residual.
  • Response ≤1 ns.
  • In=5 kA.

Low residual

  • Uc=6 V signal match.
  • Residual ≤18 V.
  • No signal interference.
  • Low false trigger.

DIN rail

  • DIN35 rail.
  • Screw terminals.
  • IN/OUT clear.
  • M5 ground.

Status indicator

  • Red/green window.
  • Failure indicator.
  • Optional remote contact.
  • Connects to VMS.

3. Specifications

Item Parameter
Model KTR-SPD12
Applicable lines RS485 / 4-20 mA / switch
Rated voltage Uc 6 V
Nominal discharge In 5 kA (8/20 μs)
Max discharge Imax 10 kA
Residual (at In) ≤18 V
Response time ≤1 ns
Wiring Screw terminal (IN/OUT/G)
Mounting DIN35 rail
Ground terminal M5 bolt
Operating temp -40~85℃
Housing Flame-retardant (UL94 V-0)

4. Reference Prices

KTR-SPD12 signal SPD (RS485/4-20 mA):Ref. USD 8~17 / pc (CNY 60~120 @7.2)

KTR-SPD12 with remote contact:Ref. USD 14~25 / pc (CNY 100~180 @7.2)

Equipotential copper bar:Ref. USD 4~11 / m (CNY 30~80 @7.2)

Outdoor signal SPD box (IP65):Ref. USD 42~85 / unit (CNY 300~600 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Outdoor transmitter to PLC signal protection.
  • RS485 bus head/tail protection.
  • Camera/access switch signal SPD.
  • Long sensor runs.
  • Room incoming signal lines.

6. Installation & Maintenance

Installation

  • Mount SPD on DIN rail in cabinet.
  • Field signal into IN.
  • OUT to protected device (PLC/instrument).
  • G to copper bar (≤0.5 m short thick wire).
  • RS485: A/B to corresponding terminals.
  • 4-20 mA: +/− to terminals.
  • Check signal not attenuated.
  • Green window = normal.

Maintenance

  • Inspect SPD pre-lightning-season.
  • Replace immediately when window red.
  • Check ground terminal tightness.
  • Measure ground resistance (≤4 Ω).
  • Log lightning event history.
  • Stock spare SPDs.

7. FAQ

  • Q:Signal SPD vs power SPD?
    A:Signal SPD (Uc=6 V) protects low-voltage signal lines, low residual (≤18 V), no signal interference; power SPD (Uc=275/385 V) protects 220/380 V power lines, high current (20~100 kA). They must not be swapped: power SPD on signal short-circuits; signal SPD on power burns.
  • Q:How many SPDs on an RS485 bus?
    A:For a daisy-chained RS485 bus, install KTR-SPD12 at the head (PLC side) and tail (farthest device). Intermediate devices generally don’t need SPD (induced surges are diverted by head/tail). If bus >200 m or crosses buildings, add SPD mid-segment too.
  • Q:Does SPD affect 4-20 mA accuracy?
    A:Normally no. SPD is in series with minimal internal resistance (mΩ), does not affect the 4-20 mA loop. But if SPD ages (window red), leakage current rises and may offset the signal. Replace immediately when red — do not delay.
  • Q:What ground resistance is required?
    A:The SPD ground terminal must connect to the equipotential bar, ground resistance ≤4 Ω (independent) or ≤1 Ω (combined). Ground wire should be short and thick (≤0.5 m, ≥2.5 mm² Cu). Poor grounding elevates equipment potential via the ground wire during surge, defeating protection.

8. Trend & Selection

Signal SPDs are trending integrated multi-channel, smart remote signaling, and low capacitance (no high-frequency impact). Industrial fieldbus (Profinet/EtherNet/IP) protection requires low capacitance (≤10 pF) for gigabit signal transparency.

9. Delivery & Service

KITOZER sizes KTR-SPD12 by signal line type (RS485/4-20 mA/switch), providing SPD layout and grounding topology. Delivery includes SPD, DIN rail, certificate. Warranty covers ground resistance testing guidance and failure replacement.

10. Additional Notes

A common pitfall is SPD ground not connected or mis-wired. The SPD G terminal must be grounded with a short, thick wire (≤0.5 m). Many sites skip grounding — the SPD is installed but G floats, equivalent to no protection. During lightning, surge cannot be diverted and equipment still damaged. Grounding is the prerequisite for SPD effectiveness.

Another pitfall is SPD installed on the equipment inner side. Correct position: signal line enters the cabinet from outdoors, passes SPD first (IN in, OUT out), then PLC/instrument. The SPD must be ‘in front’ (outdoor side) of the protected device, not behind. If reversed (OUT to outdoor), surge hits the device before SPD — no protection.

Selection summary: RS485/4-20 mA; Uc=6 V; In=5 kA; ≤1 ns; DIN rail. The signal SPD is the weak-current lightning rod — right position, good ground, periodic window check, brings peace of mind through lightning season.