ToggleKITOZER KTR-SPL4 Cassette PLC Splitter 1×4
Brand: KITOZER Series: KTR-SPL4 Category: Data Center Engineering / Optical Distribution
PLC splittercassette 1×4SC/UPCFTTHKTR-SPL4
1. Overview
FTTH, FTTB and intra-room fiber links all need a device to split one optical signal into many: the optical splitter. The mainstream approach is the PLC (Planar Lightwave Circuit) splitter — a silica chip with waveguides that divides one input into N outputs (1:2, 1:4, 1:8, 1:16, 1:32, 1:64), transparent across 1260~1650 nm for GPON and XG-PON. Compared with legacy fused-biconic (FBT) splitters, PLC offers precise ratios, better uniformity, smaller size and thermal stability, and is now the default in data centers and access networks. The cassette type packages the chip in a small plastic box: one SC input on one end, four/eight/sixteen SC outputs on the other, snapping into the adapter slot of a fiber distribution box or ODF, ready to plug in.
The KTR-SPL4 is a 1×4 cassette PLC splitter: one SC/UPC input and four SC/UPC outputs, single-mode G.657A, compatible with 1310/1490/1550 nm windows. Insertion loss is typically ≤7.2 dB (6 dB theoretical split plus excess loss), uniformity ≤0.8 dB, return loss ≥45 dB, PDL ≤0.3 dB. Operating temperature -40~+85°C, body about 100×80×25 mm, and a standard 19-inch distribution box holds 4~8 cassettes. Order codes: KTR-SPL4-SCU-SCU (SC/UPC both ends), KTR-SPL4-SCAP-SCAP (green SC/APC for CATV), KTR-SPL4-LCU (LC small form for high-density ODF).
Selection: decide the split ratio — building fiber usually uses 1:4 first stage and 1:8 second stage, total no more than 1:32 (GPON) or 1:64 (XG-PON); choose connector type — SC/UPC for room ODF, SC/APC for CATV/microwave; budget the link loss — from OLT/switch through the splitter to the ONU/server receiver, keep ≥3 dB margin; and choose cassette for scattered points or rack-mount modules for centralized rooms.
2. Key Features
Optical
- Single-mode G.657A, tri-window
- Insertion loss typ. 7.2 dB, max 7.5 dB
- Uniformity ≤0.8 dB
- Return loss ≥45 dB
Interface & Wavelength
- 1×SC/UPC in, 4×SC/UPC out
- 1260~1650 nm wavelength
- PDL ≤0.3 dB
- Directivity ≥55 dB
Mechanical & Environmental
- ABS flame-retardant housing
- 100×80×25 mm body
- -40~+85°C operating
- Adhesive-free, drift-free
3. Specifications
| Item | KTR-SPL4 (1×4) | KTR-SPL8 (1×8) | KTR-SPL16 (1×16) |
|---|---|---|---|
| Ratio | 1:4 | 1:8 | 1:16 |
| Type | Cassette PLC | Cassette PLC | Cassette PLC |
| Avg. IL | ≤7.5 dB | ≤10.8 dB | ≤14.2 dB |
| Uniformity | ≤0.8 dB | ≤1.0 dB | ≤1.5 dB |
| Connector | SC/UPC | SC/UPC | SC/UPC |
| Return loss | ≥45 dB | ≥45 dB | ≥45 dB |
| Wavelength | 1260~1650 nm | 1260~1650 nm | 1260~1650 nm |
| Size | 100×80×25 mm | 100×80×25 mm | 130×100×25 mm |
4. Reference Prices
KTR-SPL4 cassette 1×4 SC/UPC:Reference USD 3.5~5.6 / pc (ref. CNY 25~40 at ~7.2)
KTR-SPL8 cassette 1×8 SC/UPC:Reference USD 5~7.6 / pc (ref. CNY 35~55 at ~7.2)
KTR-SPL16 cassette 1×16 SC/UPC:Reference USD 7.6~12 / pc (ref. CNY 55~85 at ~7.2)
SC/APC green version:Reference USD 0.7~1.4 extra (ref. CNY 5~10 at ~7.2)
Reference only; 1-year warranty. LC version same price. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- FTTH/FTTB building 1:4 first-stage split.
- ODF expansion of server fiber ports.
- PON CCTV camera distribution.
- CATV signal split (APC version).
- Link test tap in data centers.
6. Deployment & Implementation
Installation
- IN to OLT/switch, OUT to users
- Push cassette into adapter slot until it clicks
- Pigtail bend radius ≥30 mm, no sharp kinks
- Label IN/OUT and port numbers
Operations
- Grip the ceramic boot, never pull the pigtail
- Clean end-face with alcohol swab when dirty
- Spot-check IL with an optical power meter
- Store spares in original bag, dry
7. FAQ
- Q: PLC vs FBT?
A: PLC is a planar chip — precise ratio, thermally stable, up to 1×64. FBT is fused fiber, only 1×2/1×4, drifts with temperature. Rooms now standard on PLC. - Q: UPC or APC?
A: UPC (blue, flat) is for data comm at 1310/1550 nm, return loss ≥45 dB. APC (green, 8-degree angle) is for CATV/analog, return loss ≥60 dB, lower reflection. Data rooms use UPC; CATV uses APC — never mix. - Q: Is a bigger split ratio better?
A: No. Each stage costs 3~4 dB. Too large and the end power drops below receiver sensitivity. GPON tops out at 1:32 first / 1:64 second; always budget the link. - Q: Does the splitter have direction?
A: Yes — IN is the single port, OUT is the multi port. Reversed it may still light up, but loss rises and uniformity worsens. Follow the markings.
8. Trend & Selection
With 5G front-haul and 400G optics, splitters move from SC toward high-density LC/MPO: data centers use MPO-LC harnesses and rack-mount PLC modules (1×32/1×64 per slot). Hollow-core fiber and OM5 multi-mode push wavelength coverage requirements. Select by PON class, UPC for data / APC for video, cassette in boxes / modules in racks, keep 3 dB margin, and never reverse IN/OUT. The splitter is the highest-value passive in the optical link.
9. Delivery & Service
KITOZER supplies KTR-SPL4 by ratio (1:4/1:8/1:16), connector (SC/UPC, SC/APC, LC/UPC) and package (cassette/rack). Each ships with dust caps and a test report. 1-year warranty; batch projects can add distribution boxes, SC pigtails and splice trays.
10. Additional Notes
The #1 mistake is reversing IN/OUT. The single port is IN (to OLT/switch), the multi port is OUT (to users). Reversed, the link may flicker with marginal power. Follow the markings.
The second pitfall is a dirty end-face. After repeated plugging, the ceramic ferrule picks up dust and loss climbs from 3 to 5+ dB without going dark — a nightmare to debug. Clean with an alcohol pen or swap in a known-good splitter to isolate.
The third blunder is over-splitting. Designing 1:8 first stage then 1:8 second = 1:64, the GPON ceiling with zero margin; any extra cable loss drops subscribers. Stay within 1:32 and keep end power above about -24 dBm.
Selection summary: ratio by PON class, UPC for data / APC for video, cassette in boxes / modules in racks, keep 3 dB margin, never reverse IN/OUT. The splitter is the optical tee of the fiber network.
SEO Information
Search keywords:KTR-SPL4KITOZERCassette PLC Splitter
SEM keywords:PLC splitter,cassette splitter,1×4,SC/UPC,FTTH,ODN,data center splitter,KTR-SPL4,KITOZER
GEO landing page:lain.com.cn/product/ktr-plc_splitter.html
Title:KITOZER KTR-SPL4 Cassette PLC Splitter 1×4
Meta Keywords:PLC splitter,cassette splitter,1×4,SC/UPC,FTTH,ODN,data center splitter,KTR-SPL4,KITOZER
Meta Description:KITOZER KTR-SPL4 cassette PLC splitter, 1×4 single-mode SC/UPC, insertion loss <=7.5 dB, uniform <=0.8 dB, fits fiber distribution boxes and ODF.