KITOZER KTR-SVG 500kVAr Static Var Generator

KITOZER KTR-SVG 500kVAr Static Var Generator

Brand: KITOZER Series: KTR-SVG Category: Data Center Engineering > Power Distribution

500 kVAr380V 3-phaseIGBT bridgeair/water cooledDSP+FPGA

1. Overview

The KITOZER KTR-SVG static var generator uses a voltage-source bridge topology. IGBT power modules sample grid reactive current and harmonics in real time and dynamically inject leading or lagging reactive current, pulling the power factor close to unity. The standard 500kVAr unit is offered in air-cooled and water-cooled variants, split into a control cubicle and a power-unit cubicle, suited to 380V three-phase switchrooms, data centers and industrial loads.

A DSP+FPGA core runs the compensation loop, paired with a 7-inch touch HMI and PLC protection, and communicates upstream over RS485/Modbus. The water-cooled variant adds a chiller, redundant circulation pumps and deionized-water cold plates for high-density, low-noise or sealed outdoor rooms. Compared with traditional switched-capacitor banks that step in fixed blocks, the SVG compensates continuously and symmetrically in both inductive and capacitive directions, which avoids over-correction and the hunting that plagues contactor-switched stages under light load.

2. Key Features

Fast dynamic compensation

  • 1700V/800A two-level IGBT modules deliver millisecond response to fluctuating load reactive swings.
  • 3% input reactor, 1250A main breaker with shunt trip and output filter capacitors suppress switching ripple.

Two cooling options

  • Air-cooled: 12 axial fans plus two roof fans, washable dust-and-water filters, simple to install and service.
  • Water-cooled: aluminum cold plates on a 15kW chiller with duty-standby pumps, deionized water and glycol anti-freeze for lower noise and a tighter footprint.

Protection & communication

  • PT100 sensors and Hall current/voltage transducers feed over-temperature, over-current and DC over-voltage protection.
  • The HMI shows live operating parameters; RS485/Modbus ties the unit into the power SCADA, with mushroom E-stop on both cabinet doors.

Design for duty

  • T2 tin-plated copper busbars carry the main loop; the control supply runs 1+1 redundant 24V units so a control PSU fault does not trip the whole set.
  • Independent pre-charge resistors limit inrush on the DC bus, extending capacitor and contactor life.

3. Specifications

Item Air-cooled Water-cooled
Rating 500 kVAr / 400V 500 kVAr / 400V
Cabinet 800x800x2200 ctrl+power, IP30 Same
IGBT 1700V/800A air-cooled x6 1700V/800A water-cooled x6
Main breaker 3P AC400V 1250A MCCB Same
Cooling 12 fans + 2 roof fans 15kW chiller + 2 pumps + cold plates
Control DSP+FPGA, 7″ HMI, PLC, RS485 Same + water-loop display & interlock
Water loop — Deionized >=10MOhm.cm, -25C glycol

4. Reference Price

KTR-SVG 500kVAr air-cooled set: RMB 160,000-220,000 / set

KTR-SVG 500kVAr water-cooled set (incl. chiller): RMB 240,000-320,000 / set

Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), the air-cooled set is roughly USD 22,200-30,500 and the water-cooled roughly USD 33,300-44,400. Final cost varies with voltage class, redundancy, cabinet count and protocol requirements.

Where several transformers feed a common bus, KTR-SVG cubicles can be paralleled to scale compensation from hundreds to thousands of kVAr while sharing one control HMI. The modular power-unit design lets a failed unit be pulled out and replaced without shutting down the whole compensation bank, which matters in data centers that cannot take a long power interruption.

5. Applications

  • Data center distribution: reactive and harmonic compensation for UPS and drive loads.
  • Industrial plants: welders, hoists and rolling mills with fluctuating demand.
  • Commercial buildings: mixed HVAC, elevator and lighting load energy savings.
  • Renewable tie-in: bus-voltage support at PV and wind grid-tie points.

6. Installation & Maintenance

Commissioning

  • Set the cabinets, bond the earth, land T2 copper busbars into the 380V feeder and wire the PT/CT samples.
  • Pre-charge under power, then set the compensation target on the HMI and watch the reactive-current tracking curve.

Maintenance

  • Clean air filters or check chiller water pressure, flow and resistivity on schedule.
  • Log IGBT temperatures and capacitor condition, verify protection settings and run remote inspections.

Service notes

KITOZER ships each set with a factory burn-in report, wiring diagrams and a quick-commissioning checklist. For water-cooled units we recommend annual coolant analysis and seal inspection to keep cold plates leak-free; the deionized-water loop should be topped up only with qualified coolant, never plain tap water, to avoid corrosion and fouling. Because the SVG responds within milliseconds, it also smooths flicker caused by fast-switching loads, reducing complaints from adjacent sensitive equipment and helping the site meet grid connection power-factor penalties.

SEO

Keywords:static var generator500kvarreactive compensationharmonicair cooled SVGwater cooled SVGpower factorKTR-SVG

SEM: SVG price, 500kvar static compensator, data center reactive compensation, dynamic var cabinet, water-cooled SVG

GEO landing: gdlain.com/product/ktr-svg-static-var-generator.html

Title: KITOZER KTR-SVG 500kVAr Static Var Generator | Air & Water Cooled

Meta Keywords: static var generator, SVG, 500kvar, reactive compensation, harmonic, air cooled, water cooled, power factor, KTR-SVG, KITOZER

Meta Description: KITOZER KTR-SVG 500kVAr static var generator with IGBT bridge, DSP+FPGA control, air or water cooling, millisecond dynamic compensation and power factor correction.