KITOZER KTR-TC Precision Air Conditioner and Thermal Control

KITOZER KTR-TC Precision Air Conditioner and Thermal Control

Brand: KITOZER Series: KTR-TC Category: Data Center Engineering / Precision Cooling

precision ACdatacenter专用空调in-row ACtemperature humidity controlN+1 redundancyEC fanup/down discharge7×24 operation

1. Overview

The KITOZER KTR-TC precision AC family delivers 5-120 kW cooling for data centers and temperature-controlled rooms, in room-standing, in-row and rear-door forms. It runs 7×24 with +/-1 C and +/-5% RH control, far beyond comfort AC.

Systems use scroll compressors, EC fans, electronic expansion valves and hydrophilic fin coils, with up-/down-duct or in-row horizontal airflow. N+1 parallel redundancy and group control match rack load. RS485/TCP links to DCIM for return-air temp/humidity, compressor status and filter-differential pressure.

KTR-TC pairs with hot/cold aisle containment and rack blanking panels to raise efficiency and lower PUE; outdoor condensers support air, water or glycol options.

2. Key Features

Cooling and control

  • Capacities: 5/12/20/30/45/60/90/120 kW.
  • Temperature +/-1 C, humidity +/-5% RH; integrated reheat and humidification.
  • EC fans save >30% energy vs AC fans with variable speed.

Reliability

  • Scroll compressors with duty rotation; N+1 parallel redundancy.
  • Dual power feeds with auto switch; alarm dry contacts + RS485.
  • 7×23 design life >=100,000 hours, high MTBF.

Airflow and efficiency

  • Room units up/down duct; in-row units push cold air to rack intakes.
  • With containment and blanking panels, eliminate hot spots and lower PUE.
  • Outdoor air-cooled condenser (-15 C cold start) or water/glycol.

3. Specifications

Item Config A Config B
型号 KTR-TC-12(房间级12kW) KTR-TC-R30(行间30kW)
制冷量 12kW 30kW
送风 上送风/下送风 行间水平送风
温控精度 ±1℃ ±1℃
湿控 ±5%RH(加湿+除湿) ±5%RH
风机 EC离心风机 EC直驱风机
压缩机 涡旋式 涡旋式,双压缩
通讯 RS485 + TCP RS485 + TCP
电源 380V/50Hz 380V/50Hz

4. Reference Prices

KTR-TC-12 12 kW room-standing precision AC (up-duct, incl. indoor/outdoor units): Reference price USD 5,300~7,600 / unit (ref. CNY 38,000~55,000 at ~7.2 CNY/USD)

KTR-TC-R30 30 kW in-row precision AC (horizontal airflow, for N+1 set): Reference price USD 9,000~12,500 / unit (ref. CNY 65,000~90,000 at ~7.2 CNY/USD)

Prices are reference only; final quote depends on configuration, quantity, project location and tax. Bulk orders negotiable. Currency note: CNY to USD converted at approximately 7.2 CNY/USD for reference.

5. Applications

  • Small/medium rooms: 12-30 kW room units with raised-floor plenum.
  • High-density racks: 30 kW in-row units with aisle containment.
  • Archives/museums: +/-1 C / +/-5% RH for paper preservation.
  • Labs/QA: precision environment for equipment calibration.

6. Installation & Maintenance

Installation

  • Keep indoor-outdoor refrigerant lift <=15 m; add oil charge for longer lines.
  • Seal the raised-floor plenum; align in-row units with rack rows.
  • Feed dual power from UPS and utility; daisy-chain N+1 group control.

Maintenance

  • Clean filters monthly; inspect coils and refrigerant leaks quarterly.
  • Every 6 months check compressor current, fan bearings and calibrate sensors.
  • Winter air-cooled condensers need low-ambient kits or glycol.

7. FAQ

  • Q: Precision vs residential AC?
    A: Precision AC runs 7×23, controls both temp and humidity, high airflow low delta-T, with monitoring and redundancy; residential AC is intermittent and not suited to racks.
  • Q: Do I need N+1?
    A: For critical rooms, yes. If one unit fails, the rest carry the load and avoid thermal shutdown.
  • Q: Down-duct or in-row?
    A: Down-duct room units for low density (<5 kW/rack); in-row for high density (>8 kW/rack) with containment.
  • Q: What PUE can I reach?
    A: With containment and EC fans, PUE reaches 1.4-1.5; liquid-cooled racks go lower.

8. Industry Trend & Selection

Precision cooling is shifting from room units to in-row, rear-door and liquid-cooling options, while PUE targets drive aisle containment and EC fans. KTR-TC covers 5-120 kW in room and in-row forms, with N+1 redundancy and group control to avoid hot spots in dense racks. Size cooling by rack IT load times 1.2, and lay out supply/return with hot/cold containment; use in-row or rear-door units for dense GPU racks. Clean filters monthly, calibrate temp/humidity sensors every six months, and check winter low-ambient kits on air condensers. DCIM monitors return-air temp/humidity and filter differential pressure in real time to catch cooling faults early.

9. Delivery & Service

KITOZER offers precision-AC selection, outdoor condenser installation, refrigerant brazing and group-control tuning as one service. We issue a cooling-layout drawing based on rack heat load and aisle containment, then commission indoor/outdoor units, power feed and DCIM integration. The warranty covers compressor and fan replacement; customers can add an annual maintenance package with filter change, refrigerant leak check and sensor calibration.

We provide a cooling-load calculation sheet and on-site commissioning of group-control and setpoints, and train facility staff on filter change and alarm response. Annual maintenance includes condenser cleaning and refrigerant pressure check.

10. SEO Information

Search keywords:precision air conditionerdatacenter precision ACin-row coolingconstant temperature humiditythermal controlN+1 redundancyKTR-TCKITOZER

SEM keywords: [‘precision AC price’, ’12kW server room air conditioner’, ‘in-row precision cooling’, ‘constant humidity temperature unit’, ‘datacenter cooling’, ‘KITOZER AC’]

GEO landing page: lain.com.cn/product/ktr-tc-precision-cooling.html

Title: KITOZER KTR-TC Precision Air Conditioner and Thermal Control

Meta Keywords: precision air conditioner,datacenter precision AC,in-row cooling,constant temperature humidity,thermal control,N+1 redundancy,KTR-TC,KITOZER

Meta Description: KITOZER KTR-TC datacenter precision AC, 12-30 kW, +/-1 C +/-5% RH, EC fan N+1 redundancy, in-row/room unit, aisle containment, PUE optimization.