KITOZER KTR-TH12 Data Center Temperature & Humidity Sensor (RS485 Modbus)

KITOZER KTR-TH12 Data Center Temperature & Humidity Sensor (RS485 Modbus)

Brand: KITOZER Series: KTR-TH12 Category: Environmental Monitoring / Telemetry

temp/humidity sensorRS485Modbusdata center monitoringwall-mountKTR-TH12

[Product image: KITOZER KTR-TH12 wall-mount temp/humidity sensor with LED display and RS485 terminals]

1. Overview

KITOZER KTR-TH12 is a temperature and humidity sensor that feeds the data-center environmental monitoring system. Servers are sensitive to ambient conditions: high temperature triggers thermal throttling or shutdown; low humidity builds static charge that damages chips; high humidity causes condensation and shorts. ASHRAE recommends 18~27℃ inlet air and 40~60% RH. The monitoring system deploys sensors across the hall, samples data and pushes it to the platform; on threshold breach it links to the AC and triggers alarms.

KTR-TH12 uses a digital industrial-grade SHT sensor element: temperature -20~60℃ at ±0.5℃, humidity 0~100% RH at ±3% RH. It is wall-mount in a white ABS case with a front LED display showing live T and RH. Output is RS485 Modbus-RTU, 9600/19200 bps selectable, up to 32 sensors on one RS485 bus, daisy-chained with shielded twisted pair to the host’s 485 port.

Power is DC 12~24 V wide-range, shared on a two-core shielded cable (power+signal) or fed independently. Field-wiring terminals simplify install. Mount in the cold aisle at rack-inlet height ~1.5 m — the ASHRAE reference point representing server inlet. KTR-TH12 also supports threshold settings: when T or RH crosses limits, the sensor pushes an alarm flag via Modbus; the platform receives it and triggers SMS and audible/visual alerts.

2. Key Features

[‘

Industrial accuracy

  • T ±0.5℃, RH ±3%.
  • Digital SHT probe, no calibration.
  • -20~60℃ range.

‘, ‘

RS485 Modbus-RTU

  • Standard Modbus.
  • Up to 32 sensors per bus.
  • 9600/19200 bps.

‘, ‘

LED local display

  • Live T/RH on front.
  • At-a-glance walk-round.
  • White ABS wall case.

‘, ‘

Wide-range power

  • DC 12~24V.
  • 2-wire power+signal.
  • Threshold alarm push.

‘]

3. Specifications

[‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘, ‘

‘]

Item KTR-TH12
Temperature range -20~60℃
Temperature accuracy ±0.5℃
Humidity range 0~100%RH
Humidity accuracy ±3%RH
Interface RS485
Protocol Modbus-RTU
Baud rate 9600 / 19200
Nodes/bus ≤32
Power DC 12~24V
Display LED digital
Mount Wall-mount
Case White ABS

4. Reference Prices

[‘

KTR-TH12 T/H sensor (RS485, LED, no adapter): Reference USD 17~31 / unit (ref. CNY 120~220 at ~7.2)

‘, ‘

KTR-TH12 T/H sensor (RS485 + audible alarm, with adapter): Reference USD 31~53 / unit (ref. CNY 220~380 at ~7.2)

‘, ‘

Reference only; priced by adapter/alarm. Bulk (10+) on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

‘]

5. Applications

    [‘

  • Cold-aisle T/H monitoring.
  • ‘, ‘

  • IDC environmental monitoring.
  • ‘, ‘

  • Battery room and power room sensors.
  • ‘, ‘

  • Lab and archive climate control.
  • ‘, ‘

  • Unmanned telecom sites.
  • ‘]

6. Installation & Maintenance

Installation

    [‘

  • Pick points per monitoring plan.
  • ‘, ‘

  • Wall-mount at 1.5 m in cold aisle.
  • ‘, ‘

  • Avoid AC outlets and heat sources.
  • ‘, ‘

  • Daisy-chain RS485 sensors.
  • ‘, ‘

  • Install 120 Ω terminator at bus end.
  • ‘, ‘

  • Power DC 12~24V.
  • ‘, ‘

  • Dip-switch a unique address per sensor.
  • ‘, ‘

  • Host scans and registers devices.
  • ‘]

Maintenance

    [‘

  • Compare against a reference meter quarterly.
  • ‘, ‘

  • Wipe case dust with dry cloth.
  • ‘, ‘

  • Inspect RS485 terminals.
  • ‘, ‘

  • Check terminator yearly.
  • ‘, ‘

  • Replace probe if drift >±1℃.
  • ‘]

7. FAQ

    [‘

  • Q: How far can RS485 run?
    A: Up to 1200 m at 19200 bps. Beyond that, add a 485 repeater or fiber.
  • ‘, ‘

  • Q: Can addresses conflict?
    A: Yes — each sensor needs a unique dip-switch address (1~32). Duplicate addresses corrupt the bus. Assign per the site plan and record.
  • ‘, ‘

  • Q: Why is the reading high?
    A: If the sensor is near an AC outlet or in direct sun, it reads wrong. Mount in the cold-aisle inlet, away from blast and heat.
  • ‘, ‘

  • Q: Need on-site calibration?
    A: SHT probes are factory-calibrated; no field trim needed. If systematic offset appears, correct the zero via Modbus register.
  • ‘]

8. Trend & Selection

[‘

Environmental monitoring extends from wired RS485 to wireless LoRa/NB-IoT, but RS485 Modbus remains mainstream for stability, noise immunity and cost. Sensors evolve from single T/H to multi-parameter (T/H + leak + smoke + current). KTR-TH12 is the basic T/H node — the sensory nerve of the BMS. Select: standard RS485 Modbus; unique addresses; 120 Ω terminator; cold-aisle inlet mount; threshold alarm linkage. T and RH are the most basic, most critical hall parameters — well-placed sensors give the AC tuning its reference.

‘]

9. Delivery & Service

[‘

KITOZER supplies KTR-TH12 sensors per the floor plan and rack layout, with wall bracket and terminals. We provide the point layout and address table. Warranty covers accuracy comparison and defect replacement.

‘]

10. Additional Notes

[‘

A common mistake: mounting in the hot aisle. Installers put the sensor at the rear exhaust, so it reads exhaust temp instead of inlet temp — the AC tunes to the wrong number. Mount in the cold aisle inlet.

‘, ‘

Another pitfall: star-wired RS485. Treating RS485 like Ethernet with home-runs to the host causes reflection and unstable comms. Daisy-chain the bus and add the end terminator.

‘, “

Selection summary: RS485 Modbus-RTU; ±0.5℃/±3%RH; LED; wall at 1.5 m; daisy-chain; unique address. The sensor is the BMS’s eye — correct points make AC group-control and alarms meaningful.

“]