Table of Contents
ToggleKITOZER KTR-TH22 Environment Sensor / Temp-Humidity Transmitter 4-20mA
Brand: KITOZER Series: KTR-TH22 Category: Environmental Monitoring / Temp-Humidity Sensor
temp-humidity transmitter4-20mAsensorroom environmentDCIMKTR-TH22
1. Overview
KITOZER KTR-TH22 is a temp-humidity transmitter with 4-20mA output used in data center DCIM to measure and continuously upload temperature and humidity. Room gear is sensitive to environment: high heat triggers server throttling and shutdown, low humidity promotes static and high humidity causes condensation — both hurt reliability. KTR-TH22 sits in the room, UPS room, battery room or inside a rack, sampling temp and humidity and outputting a 4-20mA analog current to the DCIM host, which plots live curves and sets high/low alarms.
4-20mA is the industrial analog standard: 4 mA equals the lower range, 20 mA the upper; current signals resist interference over long wire runs (hundreds of meters). The transmitter is usually 24V DC, two-wire (power and signal share a pair) or four-wire. An optional local LCD shows current values on site. Accuracy follows the sensor grade, suiting racks, battery rooms and CRAH supply/return that need continuous online monitoring.
In room environmental monitoring, temp and humidity are the most basic parameters. KTR-TH22, as a 4-20mA online transmitter, uploads 24/7 to the DCIM host, with over-limit alarms linked to CRAC and ventilation — a front-end sensing device for room DCIM. Compared with a USB logger, the transmitter is continuously online with no data loss, fitting formal rooms.
2. Key Features
Temp/humidity sampling
- Real-time temp and humidity.
- Stable accuracy, consistent.
- Suits long-term online monitoring.
4-20mA output
- Industrial analog current.
- Noise-immune, long wire runs.
- Two/four-wire options.
Online upload
- Wired to DCIM host.
- Live curves and alarms.
- Over-limit links to CRAC.
Local display
- Optional LCD shows current value.
- 24V DC supply.
- Wall/rail mount.
3. Specifications
| 项目 | KTR-TH22 | KTR-TH22-L(屏显) | KTR-TH22-T(单温) |
|---|---|---|---|
| 测量参数 | 温度+湿度 | 温度+湿度 | 温度 |
| 温度范围(℃) | -20~70 | -20~70 | -40~125 |
| 湿度范围(%RH) | 0~100 | 0~100 | — |
| 输出信号 | 4-20mA | 4-20mA | 4-20mA |
| 供电 | 24V DC | 24V DC | 24V DC |
| 接线 | 两线制/四线制 | 两线制/四线制 | 两线制 |
| 显示 | 无/LCD可选 | LCD屏 | 无/LCD可选 |
| 安装 | 壁装/导轨 | 壁装/导轨 | 壁装/导轨 |
4. Reference Prices
KTR-TH22 温湿度变送器4-20mA(温湿度、24V供电、两线制): Reference USD 25~53 / unit (ref. CNY 180~380 at ~7.2)
KTR-TH22-L 屏显温湿度变送器(LCD本地显示、4-20mA): Reference USD 39~72 / unit (ref. CNY 280~520 at ~7.2)
KTR-TH22-T 单温度变送器4-20mA(宽温): Reference USD 21~42 / unit (ref. CNY 150~300 at ~7.2)
Reference only; by measured parameters, screen vs no-screen and quantity; DCIM host and networking excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Room temp/humidity online monitoring.
- UPS and battery room monitoring.
- In-rack and cold-aisle sampling.
- CRAH supply/return temp-humidity.
- Front-end sensors for DCIM systems.
6. Installation & Maintenance
Installation
- Place the transmitter in the monitored area (away from direct airflow or heat sources).
- 24V DC supply, two-wire wiring.
- Run signal wires to the DCIM analog input.
- Map range (4-20mA to lower/upper limits).
- Screen models show current values on site.
- Wire multiple points to separate channels.
Maintenance
- Calibrate against a standard periodically.
- Check 24V supply and signal wires.
- Keep the probe dust-free and dry.
- Re-check thresholds against room standards.
- Keep terminals tight, corrosion-free.
7. FAQ
- Q: 4-20mA or RS485?
A: 4-20mA is analog, noise-immune and simple to wire, good for long runs; RS485 is a digital bus, multi-drop and reads more parameters. Choose what the DCIM analog module supports. - Q: Two-wire or four-wire?
A: Two-wire shares power and signal on one pair, saving wire; four-wire separates them for better noise rejection. Choose by wiring and power. - Q: What are temp/humidity standards?
A: Common room reference is 23±5 C and 40%~60% RH; set alarm thresholds by room class and equipment requirements. - Q: Does the transmitter need calibration?
A: Yes: sensors drift over time; calibrate yearly against a standard temp-humidity source to keep data accurate.
8. Trend & Selection
Room monitoring moves from single-point temp/humidity to multi-point fields and digital buses (RS485/Ethernet), but 4-20mA analog transmitters stay widely used in DCIM for noise immunity, simple wiring and broad compatibility. Choose by measured parameters (temp/humidity); pick the screen model for on-site reading; choose 4-20mA for long runs; pick RS485 for multi-parameter buses; set thresholds by room standards; calibrate periodically.
9. Delivery & Service
KITOZER supplies 4-20mA temp-humidity transmitters in volume, configured by placement and count. We provide wiring and range-setting notes. Delivery includes transmitter, bracket and manual. Warranty covers sensor drift calibration and replacement.
10. Additional Notes
The common transmitter pitfall is placing it at an air outlet or heat source. Mounted at a CRAH supply vent, it reads supply air, not the real rack environment; next to a battery, it reads local heat. Placement must represent the area, away from vents and heat sources.
Another pitfall: running signal wires in the same conduit as power. Though 4-20mA is noise-immune, parallel runs with mains still introduce hum and make readings jitter. Signal wires should be in their own conduit or with other low-voltage wires, away from mains.
Selection summary: choose parameters by need; screen model for on-site reading; place away from vents/heat; keep signal wires away from mains; calibrate periodically; set thresholds by room standards. The transmitter is the rooms environmental nerve: a continuous, well-wired nerve keeps the environment under control.
SEO Information
Search keywords:temp-humidity transmitter4-20mAsensorroom environmentDCIMKTR-TH22KTR-TH22KITOZER
SEM keywords:temp humidity transmitter price,4-20mA temp humidity sensor supplier,data center DCIM sensor,KTR-TH22
GEO landing page:lain.com.cn/product/ktr-th22-temp-humidity-transmitter-4-20ma.html
Title:KITOZER KTR-TH22 Environment Sensor / Temp-Humidity Transmitter 4-20mA
Meta Keywords:[‘temperature humidity transmitter,4-20mA temp-humidity,temp-humidity sensor,data center environment,DCIM sensor,KTR-TH22,KITOZER’]
Meta Description:KITOZER KTR-TH22 temp-humidity transmitter with 4-20mA analog output continuously samples room temp and humidity, wired to a DCIM host for online environmental monitoring.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com