Table of Contents
ToggleKITOZER KTR-WLD-20 Locating Water Leak Detection Cable (20m + Controller)
Brand: KITOZER Series: KTR-WLD-20 Category: Environmental Sensor / Water Leak
locating20 m cableRS4851 m accuracyKTR-WLD-20
1. Overview
The KITOZER KTR-WLD-20 is a locating water leak detection system consisting of a controller and a 20-meter sensing cable. It monitors under precision air conditioners, along water pipes, fire sprinklers and roof skylights in rooms and buildings. When a leak occurs, the sensing cable detects the conductive liquid, and the controller reports the leak location over RS485 (accurate to 1 meter), triggering sound/light alarms and closing related valves to protect servers and distribution gear. A locating cable is more useful than a point sensor (which knows there is a leak but not where), especially along long pipe runs.
KTR-WLD-20 uses a four-conductor sensing cable (two sense wires and two reference wires) with a conductive polymer jacket. When water contacts the cable, resistance between sense and reference wires drops; the controller measures resistance to compute leak distance (time-domain reflectometry, TDR). The controller has an LCD showing leak distance (0 to 20 m) and status (normal/leak/open), relay output (NO/NC), and RS485 Modbus to the EMCS. DC12 V supply; the cable can be extended to 200 m in 20 m sections. The cable resists acids and alkalis (plain water and condensate are detected), but oil is non-conductive and not detected (use an oil-specific cable).
Typical uses: under precision air conditioners in data centers (a blocked condensate tray leaks and soaks the underfloor servers); under restrooms in office buildings (failed waterproofing); fire sprinkler pipes in underground garages; rooftop AC units; along lab water lines; sumps in electrical cable trenches. KTR-WLD-20 alarms at the early leak stage and minimizes water damage.
2. Key Features
Locating
- TDR principle.
- 1 m accuracy.
- 0 to 20 m (extendable to 200 m).
- LCD shows leak distance.
4-wire cable
- 2 sense + 2 reference wires.
- Conductive polymer jacket.
- Acid/alkali resistant.
- Detects water and condensate.
Controller
- RS485 Modbus report.
- Relay NO/NC output.
- LCD real-time display.
- Sound/light alarm.
Flexible install
- Cable on floor or suspended.
- Mounting clips included.
- Break self-diagnosis.
- DC12 V supply.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-WLD-20 |
| Type | Locating leak detection |
| Cable length | 20 m (extendable to 200 m) |
| Accuracy | 1 m |
| Principle | TDR (4-wire conductive cable) |
| Detected liquid | Water, condensate (not oil) |
| Output | RS485 Modbus-RTU + relay (NO/NC) |
| Display | LCD leak distance and status |
| Alarm | Sound/light (buzzer + red LED) |
| Power | DC12 V |
| Power draw | 2 W |
| Operating temp | 0 to +50 C |
| Humidity | 5 to 95% RH (non-condensing) |
| Controller case | ABS wall 120x80x40 mm |
| Cable diameter | about 6 mm |
4. Reference Prices
KTR-WLD-20 locating system (20 m cable + controller): Ref. USD 83~132 / set (CNY 600~950 at 7.2)
KTR-WLD-100 extended to 100 m: Ref. USD 250~361 / set (CNY 1800~2600 at 7.2)
KTR-WLS-POINT point water sensor (no locating): Ref. USD 8~17 / pc (CNY 60~120 at 7.2)
KTR-WLD-OIL oil sensing cable (20 m): Ref. USD 125~194 / set (CNY 900~1400 at 7.2)
Cable extension section (20 m, with connector): Ref. USD 21~35 / pc (CNY 150~250 at 7.2)
Cable mounting clips (50 pcs): Ref. USD 3~6 / pack (CNY 25~40 at 7.2)
Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Under room precision AC.
- Restroom waterproofing below.
- Underground garage sprinklers.
- Rooftop AC units.
- Electrical cable trench water.
6. Installation & Maintenance
Installation
- Wall-mount the controller near the leak risk at 1.5 m height.
- Route the cable along the AC base and water pipe runs, on the floor or wall.
- Clip every 0.5 m (do not leave floating; a floating cable misses water).
- Loop the cable around the AC base, under the condensate tray.
- Connect the cable start to the controller, end to the shorting cap (reference).
- Wire RS485 A/B/G to the EMCS.
- DC12 V power.
- Commission: pour a cup of water at the cable midpoint; LCD should read about 10 m.
Maintenance
- Quarterly test with a cup of water at various points to verify accuracy.
- Wipe dust off the cable (conductive dust causes false alarms).
- Do not press the cable under other cords (crushing affects conduction).
- On break fault, check connectors.
- Cable life about 5 years (conductive polymer ages).
- Do not spray insecticide on the cable (chemical corrosion).
7. FAQ
- Q:Locating cable vs point sensor?
A:A point sensor (KTR-WLS-POINT, 60 to 120 RMB) only knows there is a leak, not where; good for small single points (one under an AC tray). A locating cable (KTR-WLD-20, 600 to 950 RMB) pinpoints to 1 m; good for long runs (20 m along an AC row). Long AC rows choose locating; single restroom trays choose point. If budget allows, prefer locating; finding a leak later saves huge time. - Q:Can the cable detect oil?
A:No. KTR-WLD-20 works on liquid conductivity; water conducts and is detected, oil does not. Oil leaks (lube oil, diesel) need an oil-specific sensing cable (KTR-WLD-OIL, which senses oil by changing polymer permittivity) at about double the price. Use water cable for condensate and AC leaks; use oil cable for diesel generator lube oil leaks. - Q:Too many false alarms?
A:Common cause: the cable lies on a dusty floor; damp dust conducts and triggers alarms. Solution: raise the cable 5 cm off the floor on clips; do not lay it on a wet floor. Another cause: a mop crosses the cable (mopping water triggers alarms). Post a “no mopping over sensing cable” sign. Adjust sensitivity in the controller menu (high/mid/low); lower sensitivity cuts false alarms but may miss small drips. - Q:Can I extend beyond 20 m?
A:Yes. KTR-WLD-20 has standard connectors; chain 20 m sections up to 200 m. Use the matching connectors; do not splice by stripping wires (contact resistance ruins locating accuracy). Accuracy stays 1 m up to 200 m; beyond 200 m accuracy drops. For longer runs, split into two controllers (each 200 m independent).
8. Trend & Selection
Leak detection moves from point sensors to locating cables. Locating improves from TDR to capacitive arrays (0.1 m accuracy). Cables move from water-only to combined water+oil. Controllers move from RS485 to LoRa wireless (no wiring, one gateway for many nodes). Automatic shutoff motorized ball valves spread in data centers (close on leak). AI leak prediction (history-based forecasting of likely leak points) grows in large data centers.
9. Delivery & Service
KITOZER sizes KTR-WLD-20 by monitoring length and points, providing cable routing diagrams and RS485 register tables. Delivery includes controller, 20 m cable, shorting cap, mounting clips, adapter and certificate. Warranty covers locating commissioning and false-alarm troubleshooting.
10. Additional Notes
A common pitfall is a floating cable. Installers tie it to a pipe 10 cm off the floor; when water leaks, it hits the floor but not the cable, and nothing is detected. The cable must lie on the floor or at the lowest point where water flows. Under an AC, lay the cable on the floor under the condensate tray.
Another pitfall is never testing after install. If the cable has been chewed by rats, no alarm fires during a real leak. Every quarter, pour a cup of water to verify the cable is intact and locates correctly.
Selection summary: locating; 20 m; RS485; 1 m accuracy; 4-wire cable. Leak detection is the last line of defense against water damage; the keys are floor-level routing, quarterly water tests, raising the cable to avoid false alarms, and an oil-specific cable for oil leaks.
Additional tip: Do not route the sensing cable in the same tray as power cables. Power interference destabilizes RS485 and causes false alarms. Run the sensing cable in its own tray, or at least 30 cm from power.
SEO Information
Search keywords:locating20 m cableRS4851 m accuracyKTR-WLD-20
SEM keywords:water leak detection cable,locating leak sensor,water sensing cable,room leak monitor,KTR-WLD-20,KITOZER
GEO landing page:lain.com.cn/product/locating-water-leak-cable-wld20.html
Title:KITOZER KTR-WLD-20 Locating Water Leak Detection Cable (20m + Controller)
Meta Keywords:water leak detection cable,locating leak sensor,water sensing cable,room leak monitor,KTR-WLD-20,KITOZER
Meta Description:KITOZER KTR-WLD-20 locating water leak detection system, 20 m cable + controller, RS485, 1 m accuracy, for room and pipe leak monitoring.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com