Table of Contents
ToggleProduct Overview
The KITOZER KYN28-12 is a metal clad withdrawable high voltage switchgear rated 12 kV for medium voltage distribution in industrial plants, substations, and commercial building incoming. The 630 A rated panel with vacuum circuit breaker protects transformers, motors, and feeders at 10 kV. It features separate compartments for busbar, circuit breaker, cable, and relay, with interlocks preventing unsafe operation. The withdrawable breaker truck allows quick replacement and testing. KYN28 is the most widely used indoor MV switchgear in China and many international markets.
Technical Specifications
Rated voltage 12 kV, rated current 630 A, rated frequency 50 Hz. Short time withstand 20 kA for 4 seconds, peak withstand 50 kA. Vacuum circuit breaker 630 A, breaking capacity 20 kA. Busbar compartment, breaker compartment, cable compartment, relay compartment separated. Mechanical and electrical interlocks. PT and CT mounted in cable compartment. Protection relay microprocessor based. Enclosure IP4X. Complies with IEC 62271-200, GB/T 3906.
Application Scenarios
KYN28 panels are used in 10 kV industrial distribution, transformer incoming and feeder panels, motor protection, capacitor bank switching, and commercial building MV substations. The withdrawable breaker truck is essential in continuous process industries where quick breaker exchange reduces downtime. Multiple panels form a switchboard line with incoming, PT, bus tie, and feeder positions.
Advantages
Metal clad segregated compartments improve safety. Vacuum breaker is maintenance free. Withdrawable truck speeds maintenance. Microprocessor relay provides comprehensive protection. Interlocks prevent operator error. Standardized design with global spare parts. Five year warranty.
Installation and Maintenance
Install on a level plinth, bolt panels, align busbar. Keep 1.5 m front for truck withdrawal and 0.8 m rear. Connect HV cables to cable compartment. Commissioning includes protection relay setting, breaker trip test, insulation test, and interlock check. Maintenance annually: clean insulators, check mechanism, test breaker. Every two years: vacuum interrupter test, relay calibration. Keep compartments closed. Use original breaker truck spare.
Price
From $5,400 per panel including 630 A VCB, microprocessor relay, CT, and PT. Differential protection and metering options are available.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com