KITOZER KYN61-40.5 35kV Metal Clad Switchgear With Vacuum Breaker

Product Overview

The KITOZER KYN61-40.5 is a metal clad withdrawable switchgear rated 40.5kV for 35kV secondary distribution and industrial substations. The cabinet uses separate metal compartments for busbar, breaker truck, cable termination, and low voltage auxiliaries, ensuring operator safety during switching and maintenance. KITOZER equips each panel with a drawout 35kV vacuum circuit breaker and microprocessor protection relay for transformer, feeder, or bus tie applications. The KYN61 is widely used in mining, metallurgy, railways, and large industrial plants.

Technical Specifications

Rated voltage 40.5kV, 50Hz, rated current 1250A, 1600A, 2000A, 2500A. Short time withstand 25kA or 31.5kA for 4 seconds, peak 63kA or 80kA. Power frequency withstand 95kV for 1 minute, lightning impulse 185kVpeak. Vacuum circuit breaker ZN85 or VD4, 1600A to 2500A, 31.5kA breaking. Busbar copper. Protection relay with overcurrent, earth fault, transformer differential, frequency protection. Indoor, IP4X, metal clad. Dimensions 1400mm wide by 2800mm deep by 2800mm high. Standards IEC 62271-200, GB 3906, CE.

Application Scenarios

KYN61-40.5 is used in 35kV incoming and outgoing feeders for industrial plants, mine substations, railway traction, 35kV solar and wind collector switches, and regional 35kV distribution substations. It also serves as the breaker feeder for 35kV to 10kV or 35kV to 0.4kV transformers.

Advantages and Features

Withdrawable breaker truck allows fast exchange. Five step interlock enforces safe sequence. The separate cable compartment allows HV cable work with breaker withdrawn. KITOZER offers options including a microcomputer relay with Modbus TCP, partial discharge sensors, cable room heaters, and an integrated pressure release duct. The 1400mm wide cabinet is optimized for 35kV insulation distances.

Installation and Maintenance

Provide a concrete floor rated for 1500kg per panel and 2500mm front clearance for breaker truck. Bond all panels to the substation ground grid. Commissioning includes relay secondary injection, breaker timing, insulation resistance, and contact resistance. Annual maintenance includes vacuum bottle inspection, auxiliary switch check, and spring charging motor test. KITOZER recommends a 10 year overhaul including SF6 gas check if applicable and breaker contact replacement at 10000 operations.

Price

From $9,800/panel. Contact +86 13922289957 for 35kV switchgear quote.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com