Table of Contents
ToggleProduct Overview
The KITOZER KYN61-40.5 is a metal clad withdrawable switchgear rated 40.5kV for 35kV secondary distribution and industrial substations. The cabinet uses separate metal compartments for busbar, breaker truck, cable termination, and low voltage auxiliaries, ensuring operator safety during switching and maintenance. KITOZER equips each panel with a drawout 35kV vacuum circuit breaker and microprocessor protection relay for transformer, feeder, or bus tie applications. The KYN61 is widely used in mining, metallurgy, railways, and large industrial plants.
Technical Specifications
Rated voltage 40.5kV, 50Hz, rated current 1250A, 1600A, 2000A, 2500A. Short time withstand 25kA or 31.5kA for 4 seconds, peak 63kA or 80kA. Power frequency withstand 95kV for 1 minute, lightning impulse 185kVpeak. Vacuum circuit breaker ZN85 or VD4, 1600A to 2500A, 31.5kA breaking. Busbar copper. Protection relay with overcurrent, earth fault, transformer differential, frequency protection. Indoor, IP4X, metal clad. Dimensions 1400mm wide by 2800mm deep by 2800mm high. Standards IEC 62271-200, GB 3906, CE.
Application Scenarios
KYN61-40.5 is used in 35kV incoming and outgoing feeders for industrial plants, mine substations, railway traction, 35kV solar and wind collector switches, and regional 35kV distribution substations. It also serves as the breaker feeder for 35kV to 10kV or 35kV to 0.4kV transformers.
The separate metal compartments ensure that an arc in the cable compartment does not propagate to the busbar compartment, protecting the rest of the switchboard. The drawout VCB truck can be withdrawn with the cable compartment closed, allowing breaker maintenance without exposing live cables. KITOZER can fit a microprocessor relay with transformer differential, overcurrent, and earth fault protection for transformer feeders. The 1400mm wide cabinet is the standard size for 35kV withdrawable switchgear worldwide.
The KYN61 can also be used as a 35kV bus tie between two transformer feeders, allowing either transformer to carry the whole substation load if the other is out of service. The VCB can switch 35kV capacitor banks with inrush current limiting reactors.
Advantages and Features
Withdrawable breaker truck allows fast exchange. Five step interlock enforces safe sequence. The separate cable compartment allows HV cable work with breaker withdrawn. KITOZER offers options including a microcomputer relay with Modbus TCP, partial discharge sensors, cable room heaters, and an integrated pressure release duct. The 1400mm wide cabinet is optimized for 35kV insulation distances.
Installation and Maintenance
Provide a concrete floor rated for 1500kg per panel and 2500mm front clearance for breaker truck. Bond all panels to the substation ground grid. Commissioning includes relay secondary injection, breaker timing, insulation resistance, and contact resistance. Annual maintenance includes vacuum bottle inspection, auxiliary switch check, and spring charging motor test. KITOZER recommends a 10 year overhaul including SF6 gas check if applicable and breaker contact replacement at 10000 operations.
Construction and Quality Assurance
The KYN61-40.5 cabinet is fabricated from 3mm steel with separate metal compartments. The drawout VCB truck rolls on heavy duty guide rails. The copper busbar is insulated with heat shrink and rated for 25kA short time. The microprocessor relay is mounted on the door. Every panel passes a 95kV power frequency test, a 185kV impulse test, and a relay secondary injection test. KITOZER provides a type test certificate and FAT report. The cable compartment has a pressure relief duct in case of internal arc.
Packaging and After Sales
Panels are shipped on a steel skid with the VCB truck in disconnected position. KITOZER provides commissioning support. The 2 year warranty covers breaker, relay, and busbar. Spare VCB trucks, relays, and springs are stocked. For mining substations, KITOZER offers a spare breaker truck for rapid swap.
KITOZER can configure the KYN61 as incoming feeder, outgoing feeder, bus tie, transformer protection, or capacitor bank. The microprocessor relay supports overcurrent, earth fault, transformer differential, and under voltage protection. The 1400mm wide cabinet can house a 2000A or 2500A VCB. The pressure relief duct directs internal arc gases upward, protecting operators in front. The VCB truck is interchangeable between panels, so one spare truck supports the whole switchboard.
The 2 year warranty covers VCB truck, relay, and busbar. For mining and industrial customers, KITOZER offers a spare breaker truck and a 5 year extended warranty.
The KYN61 is also used as a 35kV bus tie between two transformer feeders. The VCB can switch 35kV capacitor banks with inrush current limiting reactors. The pressure relief duct protects operators during internal arc faults.