The KITOZER lamppost base station bracket is a new type of base station bearing system integrating communication, lighting and landscaping. Leveraging urban existing lamppost resources, it integrates 4G/5G micro base stations, antennas, RRU/AAU and supporting equipment to realize “multi-purpose single pole and multi-network convergence”.
Adopting modular and lightweight design, the system features high load capacity, strong wind resistance, easy installation, no land acquisition requirement and landscape integration. It can be rapidly deployed on urban roads, parks, scenic spots, industrial parks and other scenarios, effectively addressing pain points of traditional macro base stations including difficult site selection, long construction cycle, high cost and poor landscape coordination, and boosting the construction of 5G new infrastructure and smart cities.

Lamppost Base Station Bracket On-site Photo
2. System Composition
The system consists of seven core modules: pole main body, base station bearing module, antenna feeder system, power supply & transmission module, lightning protection & grounding module, equipment cabin/integrated cabinet, and landscape protection module, all equipped with standardized plug-and-play interfaces.
- Pole Main Body: Q235B/Q345B steel conical pole with hot-dip galvanizing + plastic spraying anti-corrosion treatment, height ranging from 6m to 40m, providing basic load-bearing and installation platform.
- Base Station Bearing Module: Including antenna holding pole, RRU/AAU bracket, equipment mounting platform and cable fixing fittings, supporting mounting of 4G/5G equipment and cable arrangement.
- Antenna Feeder System: 4G/5G panel antennas, cluster antennas, landscape concealed antennas, feeders and jumpers, compatible with multiple frequency bands (700MHz–3.5GHz).
- Power Supply & Transmission Module: Municipal power access unit, remote power supply module, fiber splicing box, network/feeder cable windows and power adapters, supporting local/remote power supply and IP-based transmission.
- Lightning Protection & Grounding Module: Lightning rod, grounding flat steel, lightning arrester and equipotential connection terminals, complying with YD5098 standard with grounding resistance ≤4Ω.
- Equipment Cabin / Integrated Cabinet: IP55 protection grade, made of 201 stainless steel, built-in BBU, monitoring unit, cooling fan and power management module, supporting unattended outdoor operation.
- Landscape Protection Module: Antenna outer cover, lamp arm, lampshade, artificial bark/green plant decoration and anti-collision corner protectors, integrating with municipal landscapes.

Integrated Rendering of Lamppost Base Station Bracket
3. System Classification
Classified by four dimensions: pole structure, load capacity, application scenario and integration level, to match different budgets and scenario demands.
3.1 Classification by Pole Structure
- Single-arm Lamppost Bracket: Height 6–12m, single pole with single arm, light load capacity (≤50kg), suitable for residential communities, commercial streets and back alleys.
- Straight Lamppost Bracket: Height 16–20m, no lamp arm, medium load capacity (≤120kg), suitable for main roads, green belts and squares.
- Landscape Lamppost Bracket: Height 25–40m, petal/sail shaped appearance, heavy load capacity (≤200kg), suitable for parks, scenic spots and landmark areas.
- Multi-in-one Pole Bracket: Integrated communication, lighting, monitoring and traffic signal functions, height 8–15m, composite load capacity (≤150kg), suitable for main roads of smart cities.
3.2 Classification by Load Capacity
- Entry-level (Light Load): Load ≤50kg, compatible with 4G micro-station + single antenna, low budget and fast deployment.
- Mid-tier (Medium Load): Load 50–120kg, compatible with dual-mode 4G+5G + dual antennas, balancing performance and cost.
- Premium (Heavy Load): Load 120–200kg, compatible with converged 5G macro & micro stations + multiple antennas + AAU, meeting high-density coverage demands.

Workshop Production Line
3.3 Classification by Application Scenario
- Municipal Road Type: Height 8–15m, integrated street lamp + base station, applicable to primary and secondary urban roads.
- Park & Scenic Spot Type: Height 12–25m, landscape-oriented design, applicable to industrial parks, urban parks and cultural tourist attractions.
- Residential & Building Type: Height 6–10m, miniaturized and concealed layout, applicable to residential quarters and surrounding office buildings.
- Transport Hub Type: Height 15–30m, wind resistance up to Grade 12, applicable to high-speed railway stations, airports and viaduct lines.
4. System Schematic Diagram
plaintext
┌─────────────────────────────────────────────────────┐
│ Lightning Rod (Grounding) │
├───────────────┐ ┌───────────────┐ ┌───────────────┐
│ 5G Antenna (Mount Pole) │ │ 4G Antenna (Mount Pole) │ │ Landscape Cover │
├───────────────┘ └───────────────┘ └───────────────┘
│ RRU/AAU Bracket (Load-bearing) │
├─────────────────────────────────────────────────────┤
│ Feeder/Fiber (Routing Trough) │
├─────────────────────────────────────────────────────┤
│ Integrated Cabinet (BBU/Power/Monitor) │
├─────────────────────────────────────────────────────┤
│ Pole Main Body (Q345B Steel) │
├─────────────────────────────────────────────────────┤
│ Prefabricated Concrete Foundation │
└─────────────────────────────────────────────────────┘
Signal Flow
BBU (Cabinet) → Optical Fiber → RRU/AAU → Feeder → Antenna → Spatial Coverage
Power Flow
Municipal Power → Cabinet Power Module → RRU/AAU/Antenna → Grounding Protection
Lightning Protection Flow
Lightning Strike → Lightning Rod → Pole Body → Grounding Grid → Earth, protecting equipment safety

On-site Installation Construction Photo
5. System Configuration List (3 Tiers: Entry / Mid / Premium, Brand: KITOZER)
5.1 Entry-level Configuration List (Light Load ≤50kg, 4G Micro Station)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Lamppost Main Body | KITOZER-LS608 | Height 8m, top diameter Φ114mm, bottom diameter Φ219mm, wall thickness 3mm, Q235B steel, hot-dip galvanized + plastic sprayed, Grade 10 wind resistance | 1 | Pc | KITOZER | Single-arm type, grey |
| 2 | Antenna Mount Pole | KITOZER-BG40 | Length 1.2m, Φ48mm, wall thickness 2mm, Q235B, hot-dip galvanized, load ≤30kg | 1 | Pc | KITOZER | 360° adjustable |
| 3 | 4G Panel Antenna | KITOZER-ANT4G-1800 | Frequency band 1710–1880MHz, gain 18dBi, horizontal beamwidth 65°, vertical beamwidth 12°, N-type connector | 1 | Set | KITOZER | Single polarization |
| 4 | RRU Bracket | KITOZER-RS50 | Load ≤50kg, cold-rolled steel plate, electrostatic plastic spraying, compatible with Huawei/ZTE RRU | 1 | Set | KITOZER | Including fixing bolts |
| 5 | Feeder Cable | KITOZER-FEED-1/2 | 1/2 inch, 50Ω, flame retardant, length 5m | 1 | Pc | KITOZER | With integrated connectors |
| 6 | Mini Integrated Cabinet | KITOZER-CAB600 | 600×500×300mm, IP55, 201 stainless steel, built-in 1U power supply & cooling fan | 1 | Pc | KITOZER | Outdoor wall-mounted |
| 7 | Lightning Rod | KITOZER-LP100 | Length 1m, Φ16mm, 304 stainless steel, grounding resistance ≤4Ω | 1 | Pc | KITOZER | Top-mounted |
| 8 | Grounding Flat Steel | KITOZER-GR40 | 40×4mm, hot-dip galvanized, length 10m | 1 | Pc | KITOZER | For grounding grid laying |
| 9 | Landscape Antenna Cover | KITOZER-MC400 | 400×200×150mm, ABS material, grey, waterproof & UV-resistant | 1 | Pc | KITOZER | Antenna protection housing |
5.2 Mid-tier Configuration List (Medium Load 50–120kg, Dual-mode 4G+5G)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Lamppost Main Body | KITOZER-LS1216 | Height 16m, top Φ140mm, bottom Φ273mm, wall thickness 4mm, Q345B steel, hot-dip galvanized + plastic sprayed, Grade 11 wind resistance | 1 | Pc | KITOZER | Straight pole, dark grey |
| 2 | Dual-position Antenna Mount Pole | KITOZER-BG60 | Length 1.5m, Φ60mm, wall thickness 2.5mm, Q345B, hot-dip galvanized, single position load ≤60kg | 2 | Pc | KITOZER | Double-layer installation |
| 3 | 4G Dual-band Panel Antenna | KITOZER-ANT4G-900/1800 | 900/1800MHz, gain 17/18dBi, horizontal beamwidth 65°, vertical beamwidth 12°, N-type connector | 1 | Set | KITOZER | Dual frequency compatible |
| 4 | 5G Panel Antenna | KITOZER-ANT5G-3500 | 3300–3600MHz, gain 20dBi, horizontal beamwidth 65°, vertical beamwidth 10°, 4.3-10 connector | 1 | Set | KITOZER | Main 5G frequency band |
| 5 | RRU/AAU Bracket | KITOZER-RS120 | Load ≤120kg, Q345B steel, hot-dip galvanized, adjustable angle, compatible with mainstream communication equipment | 1 | Set | KITOZER | With shock-absorbing gaskets |
| 6 | Feeder Cable | KITOZER-FEED-7/8 | 7/8 inch, 50Ω low-loss, length 8m | 2 | Pc | KITOZER | 1 for 4G, 1 for 5G |
| 7 | Standard Integrated Cabinet | KITOZER-CAB800 | 800×600×400mm, IP55, 201 stainless steel, built-in 3U power, temperature-controlled fan & lightning arrester | 1 | Pc | KITOZER | Outdoor floor-standing |
| 8 | Lightning Rod | KITOZER-LP150 | Length 1.5m, Φ20mm, 304 stainless steel, grounding resistance ≤4Ω | 1 | Pc | KITOZER | Top-mounted |
| 9 | Grounding Flat Steel | KITOZER-GR50 | 50×5mm, hot-dip galvanized, length 15m | 1 | Pc | KITOZER | For grounding grid laying |
| 10 | Dual-antenna Landscape Cover | KITOZER-MC600 | 600×300×200mm, ABS anti-UV material, dark grey, waterproof & anti-aging | 2 | Pc | KITOZER | 1 for 4G, 1 for 5G |
| 11 | Feeder Cable Window | KITOZER-FW100 | 100×80mm, silicone sealing, waterproof & dustproof, matching pole openings | 1 | Pc | KITOZER | Connect cabinet and pole body |
5.3 Premium Configuration List (Heavy Load 120–200kg, Converged 5G Macro & Micro Station)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Lamppost Main Body | KITOZER-LS2530 | Height 30m, top Φ180mm, bottom Φ350mm, wall thickness 5mm, Q345B steel, hot-dip galvanized + fluorocarbon spraying, Grade 12 wind resistance | 1 | Pc | KITOZER | Landscape pole, customizable color |
| 2 | Multi-position Antenna Mount Pole | KITOZER-BG80 | Length 2.0m, Φ80mm, wall thickness 3mm, Q345B, hot-dip galvanized, single position load ≤80kg | 3 | Pc | KITOZER | 3-layer layout, 120° distribution |
| 3 | Multi-frequency Cluster Antenna | KITOZER-ANT-MULTI | 700/900/1800/2600/3500MHz, gain 18–22dBi, horizontal beamwidth 60°, vertical beamwidth 8° | 1 | Set | KITOZER | 5-in-1 multi-band integration |
| 4 | 5G AAU Bracket | KITOZER-AS200 | Load ≤200kg, Q345B steel, hot-dip galvanized + anti-corrosion coating, horizontal & vertical angle adjustable | 1 | Set | KITOZER | Compatible with Huawei/ZTE/Ericsson AAU |
| 5 | Feeder Cable | KITOZER-FEED-7/8 | 7/8 inch, 50Ω ultra-low loss, length 12m | 3 | Pc | KITOZER | With waterproof connectors |
| 6 | Reinforced Integrated Cabinet | KITOZER-CAB1000 | 1000×800×500mm, IP55, 304 stainless steel, built-in 5U power, intelligent temperature control, surge protection & smoke alarm | 1 | Pc | KITOZER | Outdoor floor-standing with anti-theft lock |
| 7 | Lightning Rod | KITOZER-LP200 | Length 2.0m, Φ25mm, 316 stainless steel, grounding resistance ≤4Ω with discharge ball | 1 | Pc | KITOZER | Top-mounted, suitable for heavy thunderstorm areas |
| 8 | Grounding Flat Steel | KITOZER-GR60 | 60×6mm, hot-dip galvanized, length 20m | 1 | Pc | KITOZER | With resistance reducing agent for grounding grid |
| 9 | Landscape-style Antenna Cover | KITOZER-MC800 | 800×400×300mm, fiberglass, artificial bark/green plant appearance, waterproof & anti-aging | 3 | Pc | KITOZER | Blend with surrounding landscapes |
| 10 | Feeder Cable Fixing Clips | KITOZER-FF50 | Φ50mm, nylon + stainless steel, flame retardant, 10pcs per set | 2 | Set | KITOZER | Neat cable arrangement on pole body |
| 11 | Remote Power Supply Module | KITOZER-PS48 | 48V DC, output power 300W, overvoltage/undervoltage/short-circuit protection | 1 | Pc | KITOZER | Supplies power for remote RRU/AAU |
| 12 | Fiber Splice Box | KITOZER-FB24 | 24-core, IP65, ABS material, compatible with single/multi-mode fiber | 1 | Pc | KITOZER | Fiber management inside cabinet |
6. Full Product Technical Specifications
6.1 Lamppost Main Body Series
- Material: Q235B (entry tier) / Q345B (mid & premium tiers) carbon structural steel, seamless tube rolling forming
- Height: 6m/8m/10m (entry); 12m/16m/20m (mid); 25m/30m/35m/40m (premium)
- Diameter: Top Φ114–180mm, bottom Φ219–350mm, wall thickness 3–5mm
- Wind Resistance Grade: Entry Grade 10 (0.55kN/m²); Mid Grade 11 (0.7kN/m²); Premium Grade 12 (0.85kN/m²)
- Anti-corrosion Treatment: Hot-dip galvanizing (≥85μm) + electrostatic/fluorocarbon spraying (≥60μm), salt spray test ≥5000 hours
- Service Life: ≥25 years under normal environmental conditions

Structural Schematic Drawing of Bracket
6.2 Antenna Mount Pole Series
- Material: Q235B/Q345B steel with hot-dip galvanized anti-corrosion treatment
- Specifications: Length 1.2–2.0m, pipe diameter Φ48–80mm, wall thickness 2–3mm
- Load Capacity: Entry single pole ≤30kg; Mid single position ≤60kg; Premium single position ≤80kg
- Adjustment Range: 360° horizontal rotation, ±15° vertical tilt with scale positioning
- Installation: Clamp-on pole mounting, welding-free and detachable
6.3 Antenna Series
- 4G Panel Antenna: 900/1800MHz, gain 17–18dBi, horizontal beamwidth 65°, vertical beamwidth 12°, N-type connector, IP65
- 5G Panel Antenna: 3300–3600MHz, gain 20dBi, horizontal beamwidth 65°, vertical beamwidth 10°, 4.3-10 connector, IP65
- Multi-frequency Cluster Antenna: 700–3500MHz, gain 18–22dBi, horizontal beamwidth 60°, vertical beamwidth 8°, multi-integrated connectors, IP65
6.4 RRU/AAU Bracket Series
- Material: Cold-rolled steel plate / Q345B steel, hot-dip galvanized or electrostatic plastic sprayed
- Load Capacity: Entry ≤50kg; Mid ≤120kg; Premium ≤200kg
- Compatibility: Fully fit mainstream RRU/AAU devices of Huawei, ZTE, Ericsson, Datang etc.
- Adjustment: Adjustable horizontal & vertical angles with calibration scales
- Protection Grade: IP54, waterproof, dustproof and anti-aging

Circular Operation Platform Rendering
6.5 Integrated Cabinet Series
- Material: 201 stainless steel (entry/mid) / 304 stainless steel (premium), plate thickness 1.2–1.5mm
- Dimensions: Mini 600×500×300mm; Standard 800×600×400mm; Reinforced 1000×800×500mm
- Protection Grade: IP55, fully waterproof and dustproof against heavy rain
- Cooling System: Passive heat dissipation for entry tier; intelligent temperature-controlled fan for mid & premium tiers (auto start-stop between -10℃~+50℃)
- Power Configuration: Entry 1U/100W; Mid 3U/200W; Premium 5U/300W, with overvoltage/undervoltage/short-circuit protection
6.6 Lightning Protection & Grounding Series
- Lightning Rod: 304/316 stainless steel, length 1.0–2.0m, diameter Φ16–25mm, grounding resistance ≤4Ω
- Grounding Flat Steel: 40×4mm/50×5mm/60×6mm hot-dip galvanized, conductivity ≥98%
- Lightning Arrester: IP65 protection, response time ≤25ns, maximum discharge current ≥60kA
6.7 Landscape Protection Series
- Material: ABS / fiberglass / anti-UV plastic, waterproof, sun-proof and anti-aging, operating temperature -30℃~+70℃
- Sizes: 400×200×150mm ~ 800×400×300mm, customized size & shape available
- Color Options: Grey, dark grey, artificial bark tone, custom municipal landscape colors
7. Full Product Application Scope

Support Frame Foundation Assembly Photo
7.1 Lamppost Main Body
- Municipal Roads: Primary/secondary urban roads, sidewalks and green belts, integrating street lighting and communication coverage
- Parks & Scenic Spots: Urban parks, cultural tourist zones and botanical gardens, landscape design balancing coverage and aesthetics
- Industrial Parks: Economic development zones, high-tech zones and manufacturing factories, high load & wind resistance for high-density coverage
- Residential Communities: Residential quarters, urban villages and apartment peripheries, mini concealed layout to ease public radiation concerns
- Transport Hubs: High-speed railway stations, airports, viaducts and bridge corridors, ultra-high wind resistance for long-distance coverage
- Smart City Projects: Multi-in-one pole programs integrating communication, lighting, monitoring and environmental sensing to build smart perception networks
7.2 Base Station Bearing & Antenna Feeder Products
- 4G/5G Micro-station Coverage: Eliminate signal blind spots and weak coverage areas in cities, boost network capacity
- Converged 5G Macro & Micro Coverage: High-capacity coverage on main roads, commercial districts and industrial parks to meet 5G high-bandwidth & low-latency requirements
- Indoor Distribution Extension: Extend signal coverage to office buildings, shopping malls and underground parking lots via lamppost base stations
- IoT Coverage: Bear data transmission for smart city IoT terminals, vehicle networking and industrial IoT equipment
7.3 Integrated Cabinet & Supporting Accessories
- Unattended Outdoor Base Stations: Replace traditional communication machine rooms to cut construction costs
- Edge Computing Nodes: Integrate edge computing hardware to support local data processing and low-latency applications
- Centralized Power & Transmission Aggregation: Centralized power supply and fiber convergence, simplifying wiring and lowering maintenance expenses
8. Full Product Advantages
8.1 Core Functional Features
- Multi-purpose Single Pole, Cost & Land Efficient Integrate communication, lighting, optional monitoring and landscaping, saving land resources and reducing overall construction cost by 30%–40%.
- Modular Design, Ultra-fast Deployment Standardized plug-and-play interfaces without dedicated machine rooms; only 2 workers needed for full installation within 1 day, cutting construction cycle by 50%.
- High Load & Wind Resistance, Safe & Stable Adopt high-strength Q345B steel with Grade 10–12 wind resistance and 50–200kg load capacity, compatible with all mainstream 4G/5G communication equipment.
- Landscape Integration, Zero Visual Pollution Identical appearance to ordinary street lamps; optional artificial bark/plant antenna covers to avoid messy exposed antennas.
- Wide Temperature Adaptation, Long Outdoor Service Life Stable operation between -30℃~+70℃, IP55 protection grade, hot-dip galvanized anti-corrosion coating with service life ≥25 years.
- Low Power Consumption, Eco-friendly Green Infrastructure RRU/AAU mounted close to antennas to cut feeder loss by 50%; total power consumption ≤300W, meeting green base station standards.
8.2 Customization Capacity
- Size Customization: Adjustable pole height 6–40m, pipe diameter and wall thickness to match specific load & wind resistance demands
- Shape Customization: Single-arm, straight, petal, sail and other landscape profiles; customizable color matching municipal design standards
- Function Customization: Integrate lighting, monitoring, environmental sensors, LED screens and charging piles to realize fully multi-in-one poles
- Interface Customization: Adapt to equipment interfaces of Huawei, ZTE, Ericsson and other brands, support private protocol docking
8.3 OEM & ODM Processing & Confidentiality Service
- OEM/ODM Manufacturing: Provide drawing design, production and private labeling; mass production cycle ≤15 days
- Full-process Confidentiality: Sign non-disclosure agreements to strictly protect design drawings, technical parameters and client data; self-developed core processes to prevent technical leakage
- Flexible Production: Support small batch (10–50 poles) and large batch (1000+ poles) orders; regular models in stock for spot delivery, urgent orders shipped within 3 days
8.4 Technical Parameter Advantages
- Ultra-high Wind Resistance: Max Grade 12 wind resistance (0.85kN/m²), suitable for coastal and strong wind regions
- Super Load Capacity: Max 200kg bearing capacity to mount 5G AAU + multi-antenna sets
- Low Signal Loss: 7/8-inch ultra-low loss feeder cable with loss ≤0.03dB/m to enhance signal quality
- High Protection Grade: IP55 cabinet & IP65 antennas, waterproof, dustproof against heavy rain, sand and salt fog
- Wide Operating Temperature: -30℃~+70℃, applicable to cold northern areas and high-temperature southern regions
9. Bid Control Parameters (* = Key Bid Control Item)
9.1 Lamppost Main Body
-
- Material: Premium tier adopts Q345B high-strength carbon structural seamless steel tube, welded pipes prohibited
-
- Height: Customizable range 6–40m to satisfy coverage demands of diverse scenarios
-
- Wind Resistance Grade: ≥Grade 11 (0.7kN/m²); coastal areas require ≥Grade 12 (0.85kN/m²)
-
- Anti-corrosion Craft: Hot-dip galvanizing ≥85μm + fluorocarbon spraying ≥60μm, salt spray test ≥5000 hours
-
- Pole Verticality Deviation: ≤1/1000 to guarantee stable vertical installation
9.2 Antenna Mount Pole
-
- Material: Q345B steel with hot-dip galvanized anti-corrosion, single position load capacity ≥60kg (mid tier)
-
- Adjustable Angle: 360° horizontal rotation, ±15° vertical tilt with scale positioning
-
- Installation Mode: Clamp-on pole mounting without welding, compatible with poles Φ219–350mm diameter
9.3 Antennas
-
- Frequency Band Compatibility: Support 700/900/1800/2600/3500MHz multi-band operation
-
- Gain Index: 4G antenna ≥17dBi, 5G antenna ≥20dBi to ensure coverage distance and signal strength
-
- Connector Standard: N-type for 4G, 4.3-10 type for 5G, matching mainstream RRU/AAU equipment
-
- Protection Grade: IP65 waterproof & dustproof for harsh outdoor environments
9.4 RRU/AAU Bracket
-
- Load Capacity: ≥120kg (mid tier), ≥200kg (premium tier), sufficient for 5G AAU mounting
-
- Material: Q345B steel with hot-dip galvanized anti-corrosion, equipped with shock-absorbing gaskets
-
- Equipment Compatibility: Fully fit Huawei, ZTE, Ericsson and other mainstream devices without extra adapters
9.5 Integrated Cabinet
-
- Material: Premium tier adopts 304 stainless steel with plate thickness ≥1.5mm, superior rust & corrosion resistance
-
- Protection Grade: IP55 fully waterproof and dustproof against heavy rain intrusion
-
- Cooling System: Intelligent temperature-controlled fan with auto start-stop between -10℃~+50℃, support remote temperature monitoring
-
- Power Supply: Rated power ≥200W with overvoltage/undervoltage/short-circuit protection, support -48V/220V input
9.6 Lightning Protection & Grounding
-
- Grounding Resistance: ≤4Ω, fully compliant with YD5098 communication lightning protection standard
-
- Lightning Rod: Premium tier adopts 316 stainless steel with length ≥1.5m, suitable for heavy thunderstorm zones
10. Targeted Industry Solutions
10.1 Urban Road Coverage Solution
Pain Points: Long narrow roads, dense pedestrian flow, difficult macro base station site selection, strict landscape appearance requirements
Solution: Adopt KITOZER-LS1216 mid-tier 16m lamppost with integrated dual-mode 4G+5G antennas; RRU mounted nearby, mini wall-mounted integrated cabinet for power supply, concealed antennas via landscape covers to realize continuous road coverage with download rate ≥100Mbps
Advantages: Fast deployment, landscape-friendly and cost-effective, compatible with municipal multi-in-one pole renovation projects
10.2 Park & Scenic Spot Coverage Solution
Pain Points: Beautiful surrounding environment, low-rise buildings, dense tourist flow, balance communication coverage and landscape aesthetics
Solution: Deploy KITOZER-LS2530 premium landscape lamppost (25–30m); artificial bark antenna covers, multi-frequency cluster antennas, heavy-duty 5G AAU brackets, floor-standing integrated cabinets for full scenic coverage with low signal interference and high visual harmony
Advantages: Perfect landscape integration, high load capacity and strong wind resistance, meeting high aesthetic standards of cultural tourist attractions
10.3 Industrial Park Coverage Solution
Pain Points: Large park areas, dense buildings, heavy signal attenuation from metal structures, demand for high-density coverage
Solution: Install KITOZER-LS1216 mid-tier 16–20m lampposts at 200–300m intervals; dual 4G+5G antennas with layered RRU/AAU mounting, centralized power supply via integrated cabinets to realize seamless indoor & outdoor park coverage with download rate ≥200Mbps
Advantages: High anti-interference performance, high-density coverage and low power consumption, stable transmission for industrial IoT data
10.4 Residential Community Coverage Solution
Pain Points: Dense high-rise buildings, massive user volume, public sensitivity to electromagnetic radiation, concealed installation requirements
Solution: Adopt KITOZER-LS608 entry-tier 8–10m single-arm lampposts with mini panel antennas, wall-mounted mini cabinets and landscape covers, installed on community green belts and side roads for signal blind spot remediation; electromagnetic radiation fully meets national standard (≤40μW/cm²)
Advantages: Concealed and attractive layout, low radiation level, low investment cost, effectively reducing resident resistance
10.5 Smart City Multi-in-one Pole Solution
Pain Points: Disordered scattered poles, resource waste, decentralized management, demand for multi-system integration
Solution: Deploy KITOZER-LS1520 multi-in-one lamppost (12–15m), integrating 4G/5G communication, LED street lighting, video monitoring, environmental sensors (PM2.5/temperature & humidity) and LED information screens; integrated cabinet centralizes power, transmission and monitoring functions to realize “multi-purpose single pole and unified network management”
Advantages: Intensive resource utilization, intelligent unified management and expandable functions, matching smart city construction demands
11. Project Application Cases
11.1 Smart Road Project, Tianhe District, Guangzhou
- Project Overview: Multi-in-one pole renovation for 10 main roads with total length 25km in Tianhe District, Guangzhou (2024); 120 sets of KITOZER mid-tier lamppost base stations deployed
- Configuration: KITOZER-LS1216 (16m), dual-mode 4G+5G antennas, integrated cabinets and landscape antenna covers
- Outcome: 100% 4G/5G road coverage with download speed ≥150Mbps; replaced separate street light & monitoring poles, cutting total investment by 35% and greatly improving urban landscape appearance
11.2 5G Full Coverage Project, West Lake Scenic Area, Hangzhou
- Project Overview: Full 5G coverage for West Lake scenic spot (2023); 80 sets of KITOZER premium landscape lamppost base stations covering lake surface, footpaths and scenic landmarks
- Configuration: KITOZER-LS2530 (25m), artificial bark landscape covers, multi-frequency cluster antennas and heavy-duty 5G AAU brackets
- Outcome: 100% 5G scenic coverage with download speed ≥250Mbps, supporting high-definition live streaming and VR tourism; fully harmonized with West Lake natural scenery without visual clutter
11.3 Industrial IoT Coverage Project, Suzhou Industrial Park
- Project Overview: Industrial IoT network coverage for electronics and manufacturing factories in Suzhou Industrial Park (2024); 200 sets of KITOZER mid-tier lamppost base stations deployed
- Configuration: KITOZER-LS1216 (20m), dual 4G+5G antennas, heavy-duty RRU/AAU brackets and integrated cabinets
- Outcome: Seamless indoor & outdoor factory coverage, stable connection for industrial IoT terminals with latency ≤20ms, supporting equipment monitoring, data collection and remote operation & maintenance
11.4 Community Signal Remediation Project, Bao’an District, Shenzhen
- Project Overview: Signal blind spot remediation for old residential communities in Bao’an District, Shenzhen (2023); 150 sets of KITOZER entry-tier lamppost base stations covering 20 residential quarters
- Configuration: KITOZER-LS608 (8m), 4G panel antennas, mini integrated cabinets and landscape covers
- Outcome: Community signal coverage rate raised from 75% to 98%, eliminating dead zones in elevators and underground parking lots; radiation level complies with national standards with greatly improved resident satisfaction
12. Common Faults, Maintenance & Upkeep
12.1 Common Faults & Troubleshooting
- Weak or No Signal
- Causes: Loose antennas, oxidized feeder connectors, power failure of RRU/AAU, faulty cabinet power module
- Inspection Steps: Tighten antenna fixing bolts, clean oxidized feeder connectors, test RRU/AAU voltage, check cabinet power supply status
- Solutions: Retighten fasteners, replace corroded connectors, restart power system, swap faulty power modules
- Tilting or Shaking Pole Body
- Causes: Foundation settlement, loose clamps, insufficient wind resistance, soft geological soil
- Inspection Steps: Measure pole verticality, inspect foundation bolt tightness, check clamp fastening, evaluate on-site wind pressure
- Solutions: Reinforce concrete foundation, retighten all clamps, install diagonal support frames, replace higher wind resistance poles
- Cabinet Water Ingress & Internal Condensation
- Causes: Aging sealing strips, unclosed cabinet doors, faulty cooling fans, excessive internal & external temperature difference
- Inspection Steps: Check sealant strips, cabinet door closure status, fan operation and internal humidity level
- Solutions: Replace aging sealing strips, fully close cabinet doors, swap damaged cooling fans, install dehumidification modules
- Lightning Protection Failure & Lightning-induced Equipment Damage
- Causes: Broken lightning rod, corroded grounding flat steel, expired lightning arrester, excessive grounding resistance
- Inspection Steps: Check lightning rod integrity, corrosion degree of grounding flat steel, lightning arrester indicator light, test actual grounding resistance
- Solutions: Replace damaged lightning rod, repair corroded grounding steel, swap expired lightning arresters, re-lay grounding grid
12.2 Routine Maintenance (Monthly Inspection; Increased Frequency in Rainy & Typhoon Seasons)
- Pole Body Inspection: Check for deformation, cracks and rust; retighten foundation bolts, test verticality and touch up peeling anti-corrosion coating
- Antenna Feeder System Inspection: Verify antenna fixation, tilt angle and intact landscape covers; clean feeder connectors and test standing wave ratio (≤1.5)
- Equipment Inspection: Check RRU/AAU operating indicators and surface temperature; inspect cabinet power supply, cooling fans and lightning arresters, clean cabinet dust filters
- Lightning Protection & Grounding Inspection: Check lightning rod and grounding flat steel for corrosion or fracture; test grounding resistance (must be ≤4Ω), clear debris around grounding grid
- Cable Inspection: Inspect feeders, optical fibers and power cables for damage, aging and loose connections; arrange cables neatly to avoid friction abrasion
12.3 Periodic Overhaul
- Quarterly Overhaul: Full inspection of component tightness, operating parameters and protection performance; test signal strength & download speed, record data and eliminate hidden hazards
- Annual Comprehensive Overhaul: Partial disassembly to inspect internal components, anti-corrosion coating thickness and cable aging; replace vulnerable spare parts (sealing strips, cooling fans, lightning arresters), recalibrate antenna angles and conduct full lightning protection performance test
13. Factory Strength & After-sales Service
13.1 Factory Strength
- Production Bases: Two major manufacturing plants in Guangzhou (Guangdong) and Hengshui (Hebei), covering total land area of 400,000 m² with annual output of 200,000 sets of lamppost base station brackets; mass production ensures on-time delivery
- Production Equipment: CNC cutting machines, automatic welding machines, 1000-ton hydraulic bending machines, full hot-dip galvanizing lines, electrostatic plastic spraying production lines and 3D coordinate measuring instruments; machining precision ±0.1mm to guarantee consistent product reliability
- R&D Team: 15 senior engineers (including 5 chief engineers) specializing in communication tower and smart lamppost R&D; holding 30 patents (10 invention patents) with leading industry technical capacity
- Quality Control: Strictly implement ISO9001 Quality Management System & ISO14001 Environmental Management System; raw material incoming inspection, in-process patrol inspection and full finished product outgoing inspection; conduct ultrasonic flaw detection, wind pressure test and load-bearing test to deliver zero-defect products
- Qualifications & Certifications: Grade 1 Professional Contracting Qualification for Steel Structure Engineering, Lightning Protection Engineering Professional Qualification, CE & RoHS certifications; all products meet national and industrial standards
13.2 After-sales Service
- One-stop Full-process Service: On-site survey → customized solution design → production manufacturing → logistics delivery → installation guidance → commissioning & activation → post-operation maintenance with exclusive one-on-one project manager
- Rapid Response Mechanism: 7×24-hour after-sales hotline; respond within 30 minutes, issue technical solution within 2 hours, on-site service within 4 hours in Guangdong Province and within 24 hours nationwide
- Quality Warranty Commitment: 5-year full machine warranty; 25-year warranty for lamppost main body, 10-year warranty for anti-corrosion coating; free repair & replacement of faulty components during warranty period, lifetime free technical support
- Free Customization Service: Complimentary on-site survey, solution optimization and construction drawing design; customize product size, appearance and integrated functions to match personalized client demands
- OEM & ODM Confidential Service: Provide private label OEM/ODM manufacturing with full-process non-disclosure agreements to protect client intellectual property and commercial information
14. Conclusion
As core equipment for 4G/5G new infrastructure and smart city construction, the KITOZER lamppost base station bracket features intensive efficiency, landscape integration, reliable safety and rapid deployment, perfectly solving long-standing pain points of traditional macro base stations including difficult site selection, high construction cost and inconsistent urban landscape. It is widely deployed on urban roads, scenic parks, industrial parks, residential communities and major transport hubs.
Backed by robust R&D capacity, large-scale production, strict quality control and comprehensive after-sales service, we deliver cost-effective products and full-scenario one-stop solutions for clients, helping telecom operators rapidly build 4G/5G communication networks, promote the construction of multi-in-one smart poles and jointly create a promising 5G intelligent future.
15. Search Keywords, SEO & Tags
15.1 Search Keywords
- Core Keywords: 4G/5G lamppost base station bracket, smart lamppost base station, lamppost micro base station, multi-in-one pole base station, 5G lamppost station
- Long-tail Keywords: Urban road lamppost base station, scenic spot 5G lamppost, industrial park smart lamppost, community signal remediation lamppost base station, smart city integrated pole base station
- Technical Keywords: Q345B lamppost base station, high wind resistance lamppost bracket, modular base station bracket, integrated cabinet base station, landscape concealed base station bracket
15.2 Tags
#4G/5GBaseStationBracket #SmartLamppost #LamppostMicroBaseStation #MultiInOnePole #SmartCity #5GNewInfrastructure #CommunicationTower #KITOZER #BaseStationSolution #IndustrialIoT