KITOZER
KITOZER

KITOZER large display RS485 TH

KITOZER KTR-TH17 Temp & Humidity Monitor / RS485 with Large Display

Brand: KITOZER Series: KTR-TH17 Category: Environmental Monitoring / Temp & Humidity Sensor

RS485 ModbusLarge LED±0.3℃±2%RH

KITOZER KTR-TH17 Temp & Humidity Monitor / RS485 with Large Display

1. Overview

The KITOZER KTR-TH17 is a room temperature and humidity sensor with a large LED display and RS485 Modbus-RTU communication, used in DCIM environmental monitoring to collect real-time room temperature and humidity. Temperature range -20 to +60°C, accuracy ±0.3°C; humidity 0-100%RH, accuracy ±2%RH. The large display uses a 3.5-digit LED or segment LCD for direct front-panel reading, wall or rack-mounted so staff can see current values while walking by. The RS485 bus supports up to 32 sensors in a hand-in-hand chain up to 1200m, connecting to the DCIM host or platform.

The KTR-TH17 has a flame-retardant ABS housing for wall or DIN-rail mounting. It uses an imported capacitive humidity element and NTC temperature probe, response time <30 seconds. Display brightness is adjustable; °C/°F switchable. RS485 parameters (baud 9600/19200, address 1-247) set via DIP switch or software. The sensor also has a relay output for threshold-based AC linkage or sound/light alarm. Compared with buried RS485 sensors without display, the KTR-TH17's large display aids on-site patrol; compared with Ethernet models, RS485 is cheaper to wire and suits multi-point room collection. Power 12-24V DC, consumption <1W.

Typical deploy: a 500㎡ room places one KTR-TH17 at each cold-aisle end, one mid-hot-aisle and one near the power distribution cabinet—four units total. The RS485 bus chains hand-in-hand, with a 120Ω terminator at the last unit, running to the telecom-room DCIM host. The large display mounts at 1.5m height facing the aisle. The DCIM platform sets temperature threshold 25±2°C and humidity 45%±10%RH; over-threshold triggers a popup and AC linkage. Select by communication (RS485/Ethernet/4G), accuracy (±0.3°C/±0.5°C) and display need; choose wall or DIN-rail by mounting.

2. Key Features

Large LED display

  • 3.5-digit LED.
  • Temp+humidity on screen.
  • Brightness adjustable.
  • °C/°F switch.

High accuracy

  • Temp ±0.3°C.
  • Humidity ±2%RH.
  • Capacitive element.
  • Response <30s.

RS485 Modbus

  • RS485-RTU.
  • 32 on bus.
  • Up to 1200m.
  • Address 1-247.

Threshold linkage

  • Relay output.
  • AC linkage.
  • Sound/light alarm.
  • To DCIM.

3. Specifications

Item KTR-TH17 (RS485 large display) KTR-TH17E (Ethernet) KTR-TH17S (DIN no display)
Temp range -20 to +60°C -20 to +60°C -20 to +60°C
Temp accuracy ±0.3°C ±0.3°C ±0.5°C
Humidity range 0-100%RH 0-100%RH 0-100%RH
Humidity accuracy ±2%RH ±2%RH ±3%RH
Communication RS485 Modbus Ethernet Modbus-TCP RS485 Modbus
Display 3.5-digit LED 3.5-digit LED None
Power 12-24V DC PoE/12V DC 12-24V DC
Mounting Wall Wall DIN rail

4. Reference Prices

KTR-TH17 RS485 large-display temp/humidity sensor: Reference USD 25 to 49 / unit (ref. CNY 180 to 350 at ~7.2)

KTR-TH17E Ethernet large-display sensor: Reference USD 49 to 83 / unit (ref. CNY 350 to 600 at ~7.2)

KTR-TH17S DIN no-display sensor: Reference USD 14 to 28 / unit (ref. CNY 100 to 200 at ~7.2)

RS485 converter / shielded cable / adapter: Reference USD 4 to 28 / set (ref. CNY 30 to 200 at ~7.2)

Reference only; varies by communication, accuracy and qty. RS485 converter and shielded cable billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Cold-aisle temp/humidity.
  • Hot-aisle temperature.
  • Power cabinet temp alarm.
  • Battery room environment.
  • Archive/warehouse monitoring.

6. Installation & Maintenance

Installation

  • Mount at 1.5m height.
  • Avoid AC blow/heat sources.
  • Hand-in-hand RS485.
  • Add 120Ω terminator.
  • DIP set address/baud.
  • Read on DCIM.

Maintenance

  • Calibrate yearly.
  • Check display brightness.
  • Verify RS485 stability.
  • Clean sensor surface.
  • Review thresholds.
  • Test relay linkage.

7. FAQ

  • Q: RS485 or Ethernet?
    A: Multi-point room collection uses RS485 (cheap, bus); single-point or remote monitoring uses Ethernet (direct IP). KTR-TH17 RS485 suits multi-node DCIM hosts.
  • Q: Display doesn’t match actual?
    A: Check if the sensor is near an AC vent or heat source; compare with a reference thermometer; if deviation exceeds ±0.5°C, return for calibration or replacement.
  • Q: How many sensors on one RS485 bus?
    A: Standard RS485 transceivers support 32; repeaters extend to 128+. KTR-TH17 addresses 1-247; the actual node count is limited by the transceiver.
  • Q: Is the large display useful?
    A: Yes. Patrol staff see current values without a computer; anomalies are visible at a glance. The no-display DIN version suits hidden in-cabinet mounting.

8. Trend & Selection

Room environmental monitoring moves from ‘single-point temp/humidity’ to ‘multi-point array + AI thermal optimization’. Place sensors at both cold-aisle ends and mid-hot-aisle; chain RS485 hand-in-hand; mount the large display where the aisle is visible; set thresholds per ASHRAE (18-27°C, 40-60%RH); link AC and alarms. Temperature and humidity are foundational to room PUE and equipment reliability—collection accuracy directly drives the cooling strategy.

9. Delivery & Service

KITOZER supplies temp/humidity sensor packages: based on room layout and monitoring points, we recommend sensor models and locations, plus RS485 converters, shielded twisted pair and power adapters, integrated with the DCIM platform. Bulk projects include calibration certificates. Drift beyond spec or dead display under warranty is replaced free.

10. Additional Notes

The common mistake is mounting the sensor at an AC vent. Vent air is far cooler than actual room air, distorting readings and making the DCIM falsely judge ‘temperature normal’. Install sensors at the cold-aisle return side or mid-hot-aisle, away from direct blow.

Another pitfall is star-wired RS485. Star branches cause signal reflection and unstable communication. Wire hand-in-hand (bus topology) with a 120Ω terminator at both ends—no star branches.

Selection summary: RS485 Modbus; large LED display; ±0.3°C / ±2%RH; relay linkage; 12-24V supply. The KTR-TH17 is the room’s thermometer—cold, hot, dry or damp, visible at a glance. We recommend at least two sensors per cold aisle plus one mid-hot-aisle point; once data flows to DCIM, a temp/humidity heat map helps judge AC airflow uniformity and local hot spots.

SEO Information

Search keywords:temperature humidity sensorroom temp humidity monitorRS485 temp humidity transmitterlarge display temp humidityDCIM temp humidityKTR-TH17KITOZER

SEM keywords:[temperature humidity sensor,room temp humidity monitor,RS485 temp humidity transmitter,large display temp humidity,DCIM temp humidity,KTR-TH17,KITOZER]

GEO landing page:lain.com.cn/product/ktr-th17-rs485-temp-humidity-sensor-large-display.html

Title:KITOZER KTR-TH17 Temp & Humidity Monitor / RS485 with Large Display

Meta Keywords:temperature humidity sensor,room temp humidity monitor,RS485 temp humidity transmitter,large display temp humidity,DCIM temp humidity,KTR-TH17,KITOZER

Meta Description:KITOZER KTR-TH17 room temp & humidity sensor, RS485 Modbus output, large LED display, accuracy ±0.3℃ / ±2%RH, for DCIM environmental monitoring.

Anchor: KITOZER · Environmental Monitoring

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart