KITOZER KTR-LCAPC3 LC Duplex APC OM3 Fiber Adapter (Coupler)

Brand: KITOZER Series: KTR-LCAPC3 Category: Data Center Engineering / Fiber Adapter

LC duplexAPCOM3ceramic sleeveKTR-LCAPC3

KITOZER KTR-LCAPC3 LC duplex APC OM3 fiber optic adapter coupler green

1. Overview

The KITOZER KTR-LCAPC3 is an LC duplex APC fiber adapter (also called coupler or flange) used on fiber patch panels, termination boxes and faceplates to couple two LC connectors together and extend the link. The duplex housing fixes transmit and receive LC ports side by side in one panel cutout, suited to paired TX/RX connections in Gigabit and 10 Gigabit OM3 links.

APC end faces are identified by a green housing; the 8-degree angle-polished ferrule gives higher return loss (less reflection) than UPC, suiting high-speed links sensitive to reflection. A zirconia ceramic alignment sleeve inside centers the two fiber cores precisely, keeping insertion loss low and withstanding repeated mating cycles.

In data center low-voltage cabling, structured wiring and fiber-to-desk projects, adapters are the basic passive connection. OM3 multimode supports 10GbE up to 300 m, and APC ends are common in broadcast, PON and reflection-sensitive links. The KTR-LCAPC3 uses an engineering plastic housing with metal clips to fit standard 19-inch patch panel cutouts.

Together with patch panels, cords and boxes, the adapter completes the fiber link; though small, it is the passive part that decides insertion loss and link stability. For bulk buys, request sampled insertion and return loss data to ensure batch consistency. LC’s small footprint enables higher port density on dense patch panels for modern data center bandwidth needs.

2. Key Features

LC duplex

  • Combined TX/RX ports.
  • One cutout, two ports, saves space.
  • Suits high-density panels.
  • Plastic housing, metal clips.

APC angle polish

  • Green housing marks APC.
  • 8-degree angled ferrule.
  • High return loss, low reflection.
  • For reflection-sensitive links.

Ceramic sleeve

  • Zirconia ceramic sleeve.
  • Precise core alignment.
  • Low insertion loss.
  • Withstands repeated mating.

OM3 multimode

  • For 50/125μm multimode.
  • Supports 10GbE short reach.
  • Matches OM3 patch cords.
  • Stable bulk supply.

3. Specifications

Item Parameter
Connector LC / LC
Configuration duplex
End finish APC (8° angle, green)
Fiber type OM3 multimode 50/125μm
Insertion loss ≤0.3 dB
Return loss ≥60 dB
Alignment sleeve zirconia ceramic
Mating cycles ≥500
Operating temp -20~70℃
Panel cutout standard LC

4. Reference Prices

KTR-LCAPC3 LC双工APC OM3适配器(单只): Reference USD 2~4 / pc (ref. CNY 15~30 at ~7.2)

KTR-LCAPC3 盒装(50只/盒,含标签): Reference USD 90~167 / box (ref. CNY 650~1200 at ~7.2)

Reference only; priced per pc. Patch cords and patch panels excluded.. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • 19-inch high-density fiber patch panels.
  • Fiber termination boxes and cross-connect.
  • Fiber-to-desk faceplates.
  • 10G multimode structured cabling.
  • Broadcast/PON reflection-sensitive links.

6. Installation & Maintenance

Installation

  • Confirm standard LC duplex cutout.
  • Clip adapter until it locks.
  • Mind green APC orientation.
  • Keep ends clean when mating.
  • Push/pull on the duplex latch.
  • Label each port.

Maintenance

  • Clean ends with a cleaner pen.
  • Avoid over-mating the sleeve.
  • Check clips for looseness.
  • Replace fallen labels.
  • Swap badly contaminated adapters.
  • Spot-check link power regularly.

7. FAQ

  • Q: Can APC mate with UPC?
    A: Not recommended; the angle-polished APC does not match a flat UPC end, causing high loss and possible scratching. Mate APC with APC and UPC with UPC.
  • Q: LC vs SC adapter interchangeable?
    A: No; LC and SC connectors differ in size and panel cutout, and cannot be interchanged.
  • Q: Can the OM3 adapter take OS2 single-mode?
    A: The adapter is a passive coupler, but 50/125 and 9/125 cores mismatch and cause high loss. Use OM3 for OM3 multimode links.
  • Q: Why is insertion loss high?
    A: Often dirty ends or a worn sleeve. Clean the jumper end first; if loss remains, replace the adapter sleeve.

8. Trend & Selection

Multi-rate optical links push bandwidth higher; compact LC gains share on dense panels, OM3/OM4 multimode is widely deployed for 10G access, and low-reflection APC ends gain share in high-speed and video links. Never mix APC with UPC, and confirm OM3 matches the cords.

9. Delivery & Service

KITOZER selects KTR-LCAPC3 adapters by panel port count and end-face type, supplying quantity, labels and mounting clips. Delivery is bulk or boxed with ceramic sleeves and metal clips. Warranty covers end-face cleaning and link-test guidance.

10. Additional Notes

A common pitfall is using APC as if it were UPC. Buying by LC only and mixing green APC into a UPC link causes a sudden loss jump and possible end-face scratching. Choose green APC or blue UPC by the link end type.

Another pitfall is dirty ends. Touching the end or letting dust into the sleeve is the main cause of high link loss. Clean with a pen before mating and keep unused ports capped.

Selection summary: LC duplex saves panel space; green APC gives low-reflection angle polish; ceramic sleeve is low-loss and durable; match OM3 to OM3; never mix APC with UPC; clean ends and keep caps on. The small adapter is the link’s connection throat — right end type and clean ends keep 10G links running at full bandwidth.

SEO Information

Search keywords:LC adapterAPCOM3fiber couplerKTR-LCAPC3KITOZER

SEM keywords:LC duplex APC adapter price,OM3 fiber coupler supplier,green APC flange,KTR-LCAPC3

GEO landing page:lain.com.cn/product/ktr-lcapc3-lc-duplex-apc-om3-fiber-adapter.html

Title:KITOZER KTR-LCAPC3 LC Duplex APC OM3 Fiber Adapter (Coupler)

Meta Keywords:LC duplex adapter,LC APC coupler,OM3 fiber adapter,green APC adapter,LC fiber flange,KTR-LCAPC3,KITOZER

Meta Description:KITOZER KTR-LCAPC3 is an LC duplex APC OM3 fiber adapter with green APC ferrule ends, ceramic sleeve, low insertion loss and high return loss, for patch panels and fiber faceplates.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart