KITOZER LC duplex OM3 multimode adapter

KITOZER KTR-LCOM3 LC Duplex OM3 Multimode Fiber Adapter

Brand: KITOZER Series: KTR-LCOM3 Category: Data Center Engineering / Fiber Cabling

fiber adapterLC duplexOM3 multimodecouplerdatacenter

KITOZER KTR-LCOM3 LC Duplex OM3 Multimode Fiber Adapter

1. Overview

A fiber adapter (flange/coupler) is the passive device that mates two fiber connectors across patch panels, boxes and modules. It aligns ferrules to keep the light path continuous. The LC connector is half the size of SC; its duplex form (Tx+Rx paired) is the mainstream high-density interface in data centers. OM3 laser-optimized 50/125μm multimode supports 10 Gbps up to 300 m, the common multimode grade for server and desktop access.

The KITOZER KTR-LCOM3 is an LC duplex OM3 multimode adapter with a precision zirconia ceramic sleeve and plastic or metal-shield housing. It mates OM3/OM4 multimode jumpers; typical insertion loss ≤0.3 dB, return loss ≥20 dB (UPC). Adapters clip individually into adapter panels or en bloc into cassette modules.

In data centers and structured cabling, KTR-LCOM3 is widely used in ODF, fiber terminal boxes and server-to-switch patching. Its small size saves half the panel space versus SC — the standard companion for 40G/100G SR ports. The adapter itself does not limit bandwidth, but alignment accuracy directly drives link loss and optical-module stability.

2. Key Features

Optical

  • Interface: LC duplex.
  • Fiber: OM3/OM4 50/125μm MMF.
  • Insertion loss: ≤0.3 dB.
  • Return loss: ≥20 dB (UPC).

Construction

  • Precision zirconia ceramic sleeve.
  • Plastic / metal-shield housing.
  • Duplex latch prevents simplex drop-out.
  • Modular clip-in panel.

Reliability

  • Mating cycles: ≥500.
  • Operating temp: -20℃~+70℃.
  • Flame retardant UL94-V0.
  • IEC/TIA compliant.

3. Specifications

Item KTR-LCOM3
Interface LC duplex
Fiber OM3/OM4 50/125μm MMF
Insertion loss ≤0.3 dB
Return loss ≥20 dB (UPC)
Sleeve zirconia ceramic
Mating cycles ≥500
Operating temp -20℃~+70℃
Housing UL94-V0

4. Reference Prices

KTR-LCOM3 LC duplex OM3 adapter (ceramic sleeve): Reference USD 0.4~1.1 (ref. CNY 3~8 at ~7.2)

Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Data center ODF.
  • Server/switch optical module patching.
  • Fiber terminal boxes.
  • 10G-to-desk, building backbone.
  • 40G/100G SR multimode ports.

6. Installation & Maintenance

Installation

  • Clip adapter into panel; latch seated.
  • Patch duplex jumpers per polarity (A-A/B-B).
  • Clean ferrule endface with a click-cleaner before mating.
  • Keep bend radius ≥50 mm (MMF).
  • Verify labels at both ends.
  • Spot-check loss with a power meter.

Maintenance

  • Clean endfaces; fingerprints/dust raise loss.
  • Replace adapters at cycle end.
  • Swap cracked ceramic sleeves.
  • Do not yank jumpers.
  • Keep spares on hand.

7. FAQ

  • Q: Can LC and SC adapters be mixed?
    A: No. LC uses a 1.25 mm ferrule, SC a 2.5 mm ferrule; sizes differ and adapters are not interchangeable. Use an LC-SC hybrid jumper instead.
  • Q: Are OM3 and OM4 adapters interchangeable?
    A: The adapter itself is generic (50/125μm zirconia sleeve), but OM4 demands cleaner endfaces. Mating an OM3 adapter with OM4 jumpers is physically fine; budget loss conservatively for OM3.
  • Q: What does 0.3 dB insertion loss mean?
    A: A link accumulates loss across adapters (4 adapters = 1.2 dB) plus jumpers and splices. The 10G SR budget on 300 m OM3 is ~2.6 dB, so too many adapters eat the budget.
  • Q: Ceramic vs bronze sleeve?
    A: Ceramic (zirconia) aligns precisely and wears slowly — the DC choice. Bronze is cheaper but wears faster, loss rising over time. Standardize on ceramic for DCs.

8. Trend & Selection

Data centers move toward 400G/800G and MPO/MTP high density, but the server-access layer still runs LC-duplex multimode. OM3/OM4 persist for 10G/25G access. Adapters evolve toward ceramic sleeves, lower loss and modular panels. Choose LC duplex; OM3/OM4; zirconia sleeve; IL ≤0.3 dB; UPC endface; flame-retardant housing; pair with endface cleaning.

9. Delivery & Service

KITOZER provides adapter sizing: based on panel port count, fiber grade (OM3/OM4) and connector type (LC/SC/FC), we configure KTR-LCOM3 quantity. Bundled with ODF, fiber boxes and jumpers. Delivery includes adapters, panels and manual. Warranty covers cleaning guidance and spot loss testing.

10. Additional Notes

A common pitfall is a dirty ferrule. Oil or dust on the ceramic endface pushes loss from 0.3 dB above 2 dB, causing module errors. Always clean with a click-cleaner before mating.

Another pitfall is reversed polarity. LC duplex is Tx+Rx; reversed polarity kills the link and wastes troubleshooting time. Standardize A-A or B-B at both ends.

Selection summary: LC duplex OM3 adapter; ceramic sleeve; low loss; UPC endface; modular panel; clean before mating. It is the socket of the fiber link — aligned and clean, 10G runs steady.

Leave 1U per port block for bend radius and heat dissipation.

SEO Information

Search keywords:KTR-LCOM3KITOZER

SEM关键词:fiber adapter, LC duplex adapter, OM3 multimode adapter, fiber flange, LC coupler, datacenter fiber, KTR-LCOM3, KITOZER

GEO landing page:lain.com.cn/product/361-fiber-adapter-lc-om3.html

Title:KITOZER KTR-LCOM3 LC Duplex OM3 Multimode Fiber Adapter

Meta Keywords:fiber adapter, LC duplex adapter, OM3 multimode adapter, fiber flange, LC coupler, datacenter fiber, KTR-LCOM3, KITOZER

Meta Description:KITOZER KTR-LCOM3 LC duplex OM3 multimode fiber adapter, zirconia ceramic sleeve, insertion loss ≤0.3 dB, UPC endface, for data center ODF and server optical patching.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart