KITOZER LC duplex OS2 singlemode adapter

KITOZER KTR-LCOS2 Fiber Adapter / LC Duplex Single-Mode OS2 Coupler

Brand: KITOZER Series: KTR-LCOS2 Category: Data Center Engineering / Fiber Connectivity

fiber adapterLC duplexsingle-mode OS2ceramic sleevelow loss

KITOZER KTR-LCOS2 Fiber Adapter / LC Duplex Single-Mode OS2 Coupler

1. Overview

A fiber adapter (also called coupler or flange) is the “interface relay” of a fiber link. A patch cord runs from equipment to the ODF panel; behind the panel the cable is spliced to pigtails. To join two fibers at the panel, the adapter bridges them — one side plugs the equipment patch cord, the other the pigtail, and an internal ceramic sleeve aligns the two ferrules so the optical signal passes smoothly. The KITOZER KTR-LCOS2 series is purpose-built for LC duplex single-mode OS2. LC is the dominant high-density connector in data centers (small square, half the size of SC); duplex means two LC ports side by side, transmit and receive as a pair. OS2 is the single-mode standard (9/125μm) for long-reach links. KTR-LCOS2 uses high-precision zirconia ceramic sleeves for coaxial ferrule alignment, low insertion loss and high return loss for OS2 links.

In data center ELV systems, LC adapters are densely installed in fiber distribution frames (ODF), terminal boxes and outlet panels. A 48-port ODF typically holds 24 LC duplex adapters (48 cores total). Though small, the adapter is critical to link loss and reliability — misaligned ferrules or dirty end faces directly cause attenuation to exceed budget.

2. Key Features

Connector spec

  • Type: LC duplex, integrated duplex clip.
  • Mode: single-mode OS2 (9/125μm), blue body.
  • Polish: UPC; APC optional.
  • Use: LC-LC coupling of patch cord and pigtail.

Optical performance

  • Insertion loss: ≤0.2 dB.
  • Return loss: ≥50 dB (UPC).
  • Repeatability: ≤0.1 dB.
  • Interchangeability: ≤0.2 dB.

Construction

  • Sleeve: zirconia ceramic, precision bore.
  • Body: engineering plastic/metal, snap-in.
  • Mount: snap into ODF SC square cutout.
  • Color: blue (single-mode OS2 standard).

3. Specifications

Item KTR-LCOS2-UPC KTR-LCOS2-APC
Type LC duplex UPC LC duplex APC
Mode SM OS2 (9/125) SM OS2 (9/125)
Polish UPC (blue) APC (green)
Insertion loss ≤0.2 dB ≤0.3 dB
Return loss ≥50 dB ≥60 dB
Sleeve Zirconia ceramic Zirconia ceramic
Mount SC cutout SC cutout

4. Reference Prices

KTR-LCOS2-UPC LC duplex SM UPC adapter (ceramic, blue): Reference USD 1.1~2.1 (ref. CNY 8~15 at ~7.2)

KTR-LCOS2-APC LC duplex SM APC adapter (ceramic, green): Reference USD 1.7~3.1 (ref. CNY 12~22 at ~7.2)

Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • ODF panel adapter mounting.
  • Terminal box pigtail-to-patch coupling.
  • Fiber rack/outlet panel LC ports.
  • Single-mode OS2 long-reach links.
  • CATV, PON and data center fiber cabling.

6. Installation & Maintenance

Installation

  • Snap adapter into ODF SC square cutout.
  • Align duplex LC up/down with Tx/Rx.
  • Clean end faces before insertion (cleaner pen).
  • Push in until click.
  • Test link loss with power meter/OTDR.

Maintenance

  • Fit dust caps on unused adapters.
  • Clean ferrule end faces before each mating.
  • Re-seat loose adapters.
  • Replace sleeve/adapter if loss exceeds spec.
  • Limit mating cycles (≤500 per adapter).

7. FAQ

  • Q: Can UPC and APC adapters be mixed?
    A: No. UPC (blue) is flat-polish; APC (green) is 8° angle-polish. Mating them scratches end faces and spikes loss. Both ends of a link must match.
  • Q: LC duplex vs SC duplex?
    A: LC is small (small square), high density, mainstream in data centers; SC is larger (big square), still on legacy gear. LC adapters usually snap into standard SC cutouts.
  • Q: How many LC duplex adapters per ODF?
    A: One LC duplex adapter = 2 cores (Tx/Rx). A 48-core ODF takes 24 LC duplex adapters.
  • Q: Is 0.2 dB insertion loss large?
    A: A splice is ~0.1 dB; an adapter ~0.2 dB. In high-density links many adapters add up; keep total loss within equipment budget.

8. Trend & Selection

Data centers move to high density and high bandwidth; LC, smaller than SC, is mainstream, and OS2 single-mode rises in long-reach and high-bandwidth (100G/400G) links. APC angle-polish grows in CATV, PON and high-speed links for higher return loss. Use blue UPC or green APC for OS2; choose LC duplex for high-density ODF; end-face cleaning is key to loss control; keep UPC/APC consistent on a link.

9. Delivery & Service

KITOZER provides LC adapter selection: based on ODF capacity, core count and link requirements, we configure LC duplex UPC/APC adapter quantities. Bundled with ODF frames, terminal boxes and LC patch cords. Delivery includes adapters (by piece) and dust caps. Warranty includes insertion-loss sampling and replacement.

10. Additional Notes

The most common pitfall is mixing UPC and APC. Blue UPC and green APC look different, but mixing them — the angled ferrule hitting a flat one — scratches faces and jumps loss from 0.2 dB to over 1 dB while damaging patch ferrules. Match colors on site: blue to blue, green to green.

Another pitfall is mating without cleaning. The adapter sleeve is clean, but a dust-contaminated patch ferrule drags dirt into the sleeve, polluting the next ferrule. Wipe the end face with a cleaner pen before insertion — the most basic field practice.

Selection summary: LC duplex single-mode OS2; never mix blue UPC with green APC; snap into SC cutout; clean before mating; test link loss. Small as it is, the fiber adapter is the throat of link reliability — one dirty adapter can make the whole link intermittent.

SEO Information

Search keywords:KTR-LCOS2KITOZER

SEM keywords:fiber adapter,LC duplex adapter,single-mode OS2 coupler,LC fiber flange,fiber coupling adapter,KTR-LCOS2,KITOZER

GEO landing page:lain.com.cn/product/344-fiber-adapter-lc-lcos2.html

Title:KITOZER KTR-LCOS2 Fiber Adapter / LC Duplex Single-Mode OS2 Coupler

Meta Keywords:fiber adapter,LC duplex adapter,single-mode OS2 coupler,LC fiber flange,fiber coupling adapter,KTR-LCOS2,KITOZER

Meta Description:KITOZER KTR-LCOS2 LC duplex single-mode OS2 fiber adapter/coupler for LC connections in ODF and terminal boxes, ceramic sleeve, low insertion loss, for single-mode OS2 fiber links.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart