The KITOZER LC UPC to LC UPC single-mode fiber patch cord is a duplex OS2 jumper engineered for patching between switches, routers, ODF frames, and wavelength division multiplexing equipment in enterprise data centers and telecom rooms. The 2 mm tight-buffered cable jacket is LSZH rated for safe indoor use, and the LC connectors use ceramic ferrules with UPC polish for low insertion loss and high return loss. The 3 m length suits top-of-rack patching where short, clean jumpers keep cable management channels uncluttered. Every cord is 100 percent tested for insertion loss, return loss, and end-face geometry before shipping.
Table of Contents
ToggleTechnical Specifications
Connector: LC UPC duplex on both ends, ceramic ferrule 1.25 mm. Fiber: OS2 single-mode 9/125 um, 2 mm tight buffer, LSZH jacket. Length: 3 m standard, custom lengths available. Optical: insertion loss less than 0.2 dB, return loss greater than 50 dB UPC, repeatability less than 0.1 dB, temperature -20 C to +70 C. Compliance: Telcordia GR-326, RoHS, LSZH. Jacket color: yellow. Brand: KITOZER, 3 year warranty.
Applications
This LC-LC patch cord is the default jumper for 10GBASE-LR, 25GBASE-LR, and 100GBASE-LR4 links in data center top-of-rack environments. It patches server NICs to top-of-rack switches, switch ports to ODF frames, and ODF frames to optical transceivers. Telecom central offices use it between wavelength mux equipment and patch panels. Enterprise server rooms and campus IDFs rely on it for general fiber patching. It is also used in SAN director interconnects and out-of-band management network links.
Key Advantages
Ceramic ferrules with UPC polish deliver consistent low insertion loss across thousands of mating cycles. The LSZH jacket emits low smoke and zero halogen in a fire, meeting data center safety codes. The 2 mm slim cable bends tightly without inducing macrobending loss, which helps in dense patch channels. Yellow jacket color immediately identifies single-mode fiber on sight. Every cord ships with a test report listing measured insertion and return loss, so installers can trust the link budget without re-testing. Boot design reduces strain on the ferrule during repeated plugging.
Installation and Maintenance
Remove the dust caps only when ready to patch. Clean the ferrule end face with a one-click cleaner or lint-free wipe dampened with isopropyl alcohol before insertion. Inspect the end face with a fiber microscope to confirm no scratches or contamination. Insert the LC connector until you hear a click, and dress the cord in the vertical management channel with bends larger than 30 mm. Avoid crushing cords under heavy cable bundles. When removing, pull the connector body rather than the cable. Store spare cords with dust caps installed and coiled to a diameter larger than 150 mm. Replace any cord with visible jacket damage or measured insertion loss above 0.3 dB.