KITOZER
KITOZER

KITOZER LC-LC Singlemode Fiber Patch Cord 3m UPC Duplex

Product Overview

The KITOZER LC-LC singlemode duplex fiber patch cord provides a high-performance jumper between fiber optic equipment, patch panels, and ODF frames in data centers and telecom rooms. Built with G.657A2 bend-insensitive fiber and zirconia ceramic ferrules, the cord delivers stable low-loss connections across every mating. The duplex construction joins transmit and receive fibers in a single jacket, simplifying routing between switch ports and ODF adapters. Standard lengths from 1m to 30m are available, with custom lengths on request.

The LC connector uses a 1.25mm zirconia ferrule and a plastic latch that clicks into the adapter. The blue boot identifies UPC polish, while green indicates APC. The LSZH jacket is halogen-free and flame-retardant, meeting data center safety codes. Every cord is factory tested with an interferometer and light source, and a test report is included with bulk orders.

Technical Specifications

Connector: LC UPC on both ends, zirconia ceramic ferrule, 1.25mm. Fiber: G.657A2 singlemode 9/125um, bend-insensitive. Jacket: LSZH OFNR, 2.0mm duplex, yellow. Length: 3m standard, custom available. Insertion loss: less than 0.2dB UPC, typical 0.1dB. Return loss: greater than 50dB UPC. Repeatability: less than 0.1dB after 1000 matings. Operating temperature: -20C to +70C. Durability: greater than 1000 cycles. Includes: dust caps on both ends. KITOZER, 3 year warranty.

The G.657A2 fiber supports a minimum bend radius of 10mm, allowing tight routing in dense cable trays without signal loss. The zirconia ferrule provides 1um concentricity for consistent insertion loss. The LSZH jacket emits low smoke and zero halogen in a fire, meeting IEC 60754 and IEC 61034 requirements. Connector boots are strain-relieved to prevent fiber breakage near the ferrule.

Applications

This patch cord is used to connect 10G/25G/100G switch SFP/SFP+/QSFP ports to ODF panels, to link patch panels between racks, and to connect routers and firewalls to fiber distribution frames. It is also used for test equipment jumpers, temporary network extensions, and structured cabling cross-connections.

In a data center, one end plugs into a switch SFP port and the other into an ODF LC adapter, with the cable routed through a horizontal cable management ring. In enterprise wiring closets, patch cords link the patch panel to the switch. The 3m length is the most common for front-rack patching, while 5m and 10m lengths are used for inter-rack connections.

Key Advantages

The G.657A2 fiber supports a 10mm bend radius, allowing tight routing in dense cable trays without signal loss. Zirconia ferrules deliver consistent insertion loss across thousands of mating cycles. The LSZH jacket is halogen-free and flame-retardant, meeting data center safety requirements. Color-coded boots (blue for UPC, green for APC) help technicians identify polish type at a glance. Every cord is factory tested with an interferometer and light source.

The duplex jacket keeps transmit and receive fibers paired, reducing tangle compared with two separate simplex cords. The LC latch releases easily with a finger pull, even in dense port blocks. Dust caps are tethered to the connector so they cannot be lost. Bulk packs include a labeled bag for easy inventory.

Installation and Maintenance

Remove dust caps immediately before mating. Clean the ferrule end face with a lint-free wipe dampened with 99 percent isopropyl alcohol or a one-click cleaner. Insert the LC connector until it clicks into the adapter. Do not exceed the minimum bend radius of 30mm during routing. Secure cords with hook-and-loop ties, not nylon cable ties, to avoid over-compression. Label both ends.

During maintenance, reclean end faces before every re-mating. Inspect connectors annually for dirt or scratches using a video microscope. Replace a cord if insertion loss drifts above 0.3dB or if the jacket is damaged. Do not pull on the cord to disconnect; press the latch. Store unused cords with dust caps installed.

Packaging and Compliance

Cords are packed in polybags of 10 or 50 pieces, with a label showing length, type, and lot number. Each carton includes a test report. RoHS and IEC compliant. Custom lengths, APC polish, OM3/OM4 multimode, and other connector combinations (LC-SC, LC-ST, LC-FC) are available on request.

In a typical data center rack, a 3m LC-LC cord runs from the SFP+ port on a top-of-rack switch to an LC adapter on the rear ODF. The cord is dressed in a horizontal cable management ring and secured with hook-and-loop ties every 200mm. The blue UPC boot signals singlemode, so technicians can trace the link visually. Because the G.657A2 fiber tolerates tight bends, the cord can turn 90 degrees within the cable ring without measurable loss. Over a three-year service life, each cord may be re-mated hundreds of times during Moves Adds and Changes, and the zirconia ferrule maintains its low insertion loss throughout.

Price

From $4.5/pc. Contact +86 13922289957 for wholesale patch cord pricing.