Table of Contents
ToggleProduct Overview
The KITOZER locating water leak detection system pinpoints the exact location of a water leak along a continuous sensing cable laid under raised floors, along chiller pipes, around air handling units, and in ceiling voids. Unlike non-locating systems that only tell that a leak happened somewhere on the zone, the locating controller measures the electrical characteristic of the cable and computes the distance from the controller to the wet point, giving operators the exact spot to investigate. The sensing cable is a pair of conductive wires coated with a water-sensitive polymer, and when liquid water bridges the wires, the controller detects the change in resistance and reports position within plus minus 1 meter. Up to 100 meters of cable can be monitored per zone, and multiple zones can be aggregated by a central receiver over Modbus TCP or SNMP.
Technical Specifications
Controller: up to 2 locating zones per unit, each up to 100 meters cable. Cable: 2 conductor, water sensitive polymer coating, detects conductive liquids including water, coolant, and diluted acids. Location accuracy: plus minus 1 meter. Response time: under 5 seconds. Alarm: leak detected, location distance, cable break, controller fault. Display: 5 inch color LCD, zone map with leak position. Digital IO: relay output for local alarm, dry contact input for reset. Communication: Ethernet Modbus TCP, RS485 Modbus RTU, optional SNMP, Web HMI. Power supply: 85 to 265VAC or 24VDC. Mounting: DIN rail or wall. Cable accessories: mounting clips, end terminator, connector. Standards: CE, 5 year warranty on controller, 2 year warranty on cable.
Application Scenarios
The locating system is installed under raised floors in data centers, along chiller and CRAH piping in mechanical rooms, around air handling units, under sinks in server rooms, and in ceiling voids above dropped ceilings. It is used in commercial buildings to detect pipe leaks in wet risers, in hospitals to protect electrical rooms, in industrial plants to monitor coolant leaks, and in museums and archives to protect sensitive contents. In data centers, it is the standard leak detection layer for under-floor water systems. In green buildings, it supports sustainability by alerting on water waste. Multi-zone aggregation covers large floors without running long cable back to one controller.
Key Advantages
Locating capability tells operators exactly where to look, reducing response time and preventing invasive floor digging to find a leak. The cable detects conductive liquids including water and coolant, not just pure water. Up to 100 meters per zone covers long pipe runs. Cable break detection alerts if the cable is damaged, preventing blind spots. The controller integrates Modbus TCP, SNMP, and Web HMI, feeding DCIM and BMS. Relay outputs enable local alarm and shutdown of leak source valves. The system is easy to retrofit under raised floors without taking the room out of service. The 5 year controller warranty and 2 year cable warranty reflect field proven design.
Installation and Maintenance Recommendations
Lay the sensing cable along the likely leak path, with loops under pipes, around AHU drain pans, and near equipment bases. Do not stretch the cable, leave service loops at corners, and use mounting clips to keep it off the floor finish. Connect the end terminator to the far end. On commissioning, perform a wet test at a known distance and verify the reported location within plus minus 1 meter. Maintenance: visually inspect cable annually, test wet response on each zone quarterly, and clean the cable if dust or conductive powder accumulates. Replace cable after a major leak or physical damage. For data center deployments, integrate leak alarms with BMS and set up automatic shutdown of the affected chiller or valve via relay output.
The locating cable tells operators exactly where the leak is, within plus minus 1 meter, which cuts response time and avoids invasive floor digging. The cable detects water, coolant, and most conductive liquids, and cable break detection prevents blind spots. Relay outputs can automatically shut off the affected chiller or valve, limiting water damage.
Ordering Information
The locating leak controller is supplied as a DIN rail unit with 2 zone inputs, 10 meters of sensing cable, mounting clips, end terminators, and a power supply. Additional cable is ordered by the meter in 50 meter or 100 meter reels. The standard controller includes a 5 inch LCD showing leak position, Ethernet Modbus TCP, RS485, relay outputs, and dry contact reset. Optional packages include SNMP, Web HMI, a multi-zone aggregation unit for large floors, and a valve shutoff interface for automatic isolation. The sensing cable detects water, coolant, and most conductive liquids. Lead time is one to two weeks. KITOZER provides a cable layout drawing, a register list, and commissioning support. The five year warranty covers the controller, and the cable carries a two year warranty.
Price
From $680 per 2 zone controller, sensing cable from $12 per meter. Contact the factory for multi-zone aggregation and valve shutdown integration. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com