The KITOZER Leaky Feeder Cable 1-5/8 inch 800-2700MHz Tunnel DAS is a radiating coaxial cable designed to deliver uniform cellular and public-safety coverage inside long tunnels, underground railways, mines, parking garages, and high-rises where conventional antennas cannot provide continuous coverage. A precision-slotted outer conductor leaks controlled amounts of RF energy along the entire cable length, producing a continuous coverage corridor rather than discrete antenna cells. The cable jacket is halogen-free, flame-retardant, and UV-stabilized for direct burial and plenum installation.

The inner conductor is solid copper to minimize loss, and the dielectric is a closed-cell PE foam that preserves 50 ohm impedance across temperature. The slotted outer conductor is corrugated aluminum, which allows tight bending without kinking. The LSZH jacket is printed every meter with a sequential length marker, so installers know exactly how much cable is left on the reel without measuring. Factory-terminated ends are available with 7-16 DIN or N-type connectors, tested for PIM below minus 150 dBc.

Technical Specifications

Cable size: 1-5/8 inch (41 mm). Frequency range: 800 MHz to 2700 MHz. Characteristic impedance: 50 ohm. Velocity factor: 0.87. Coupling loss: 75 dB plus or minus 4 dB at 2 meters. Transmission loss: 0.045 dB per meter at 900 MHz, 0.075 dB per meter at 2100 MHz. Shielding effectiveness: 100 dB. Jacket: flame-retardant LSZH. Minimum bend radius: 250 mm. Weight: 1.8 kg per meter. Reel length: 500 m. Operating temperature: minus 40 to plus 70 degrees Celsius. Compliance: CPR Euroclass B-s1,d1, IEC 60332, CE, ROHS.

Applications

This leaky feeder is installed in road and rail tunnels, underground metro stations, mine adits, multi-story parking garages, airport baggage tunnels, and high-rise elevator shafts. It supports multi-operator cellular, public safety radio, and train-to-wayside communication in a single radiating system, eliminating the need for repeated donor antennas and leaky amplifiers every 100 meters.

Mining operators use the same cable in underground adits to carry both safety radio and sensor telemetry. Metro system integrators pair it with bi-directional amplifiers every 400 meters to cover 20 km of tunnel on a single head-end. Highway authorities install it in road tunnels to carry driver safety radio and mobile phone coverage for emergency calls. Large basement parking garages use it to meet public-safety codes that require first-responder radio coverage in every corner.

Advantages

Because the radiating slots are punched continuously along the cable, coverage is uniform within plus or minus 4 dB over hundreds of meters, unlike discrete antennas that create dead zones between radiators. The 1-5/8 inch diameter handles 500 W of RF power, allowing long run lengths before the next bi-directional amplifier is required. The LSZH jacket meets tunnel fire codes in most countries and does not release halogen gas in a fire, protecting first responders. KITOZER pre-punches the coupling slots to a controlled opening so coupling loss is stable across temperature and humidity.

The corrugated outer conductor allows tight bend radius without kinking, which matters in tunnels where the cable must navigate around ventilation ducts and cable trays. The sequential length printing lets installers track run length without a separate measuring wheel, reducing installation errors. KITOZER offers both low-coupling-loss variants for long tunnel runs and high-coupling-loss variants for dense urban underground stations where signal must not bleed out into adjacent streets.

Installation and Maintenance

Unroll the cable from the reel using a cable basket to avoid kinking, and support it every 1.5 meters along the tunnel ceiling using the supplied stainless steel hangers. Maintain a minimum 30 cm separation from power cables to prevent interference. Terminate both ends with 7-16 DIN connectors and install a 50 ohm termination load at the far end. After pulling, use a vector network analyzer to verify VSWR below 1.3 across the band and to confirm coupling loss at 5 meter intervals. Routine maintenance is annual visual inspection of hangers and connector boots.

KITOZER also supplies a complete tunnel DAS kit that pairs the leaky feeder with bi-directional amplifiers, head-end units, and termination loads, so integrators can order the entire radiating system from one supplier. The kit is pre-configured for the local operator band and public-safety frequencies, and KITOZER provides a free link-budget design service that recommends amplifier spacing based on tunnel length, radius, and train speed. Every reel ships with a factory VSWR and coupling-loss report, and the serial number is registered in the KITOZER warranty portal the moment the reel leaves the factory. Regional stocking partners keep 500 m reels on hand so rush replacements can ship within 48 hours, and KITOZER provides a 10 year warranty on the cable jacket against UV cracking and water penetration.

Pricing

From $32 per meter. Contact KITOZER for tunnel project bulk pricing and connector kits.