Table of Contents
ToggleProduct Overview
The KITOZER stainless steel liquid cooling pipe is a pre-cut, pre-bent 316L tubing assembly for row supply and return loops, CDU risers, and manifold headers. Each pipe section is delivered with welded ends, welded flanges, and electropolished internal bore to minimize fouling and pressure drop. The pipe supports 10 bar working pressure and is compatible with water, 25 to 40 percent propylene glycol, and dielectric coolants. Pre-bent elbows and tees reduce on-site welding, shortening installation time from weeks to days. Each section is factory pressure-tested and tagged with a serial number for traceability.
The pipe is seamless 316L stainless steel with 1.5 mm wall thickness, selected for corrosion resistance in long-life glycol loops. The internal bore is electropolished to Ra 0.8, reducing fouling and pressure drop over decades. Pre-bent elbows, tees, and reducers are welded in the factory, eliminating on-site welding and brazing. Each section is pressure-tested to 15 bar for 30 minutes before shipment and tagged with a serial number for audit and spare parts ordering.
Technical Specifications
Material: 316L stainless steel, seamless, wall thickness 1.5 mm. Sizes: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100. Design pressure 10 bar, temperature range minus 20 to 120 C. Ends: welded flange PN16 or grooved coupling. Internal bore: electropolished Ra 0.8. Fittings: 90 degree elbow, 45 degree elbow, tee, reducer, cap. Pressure tested at 15 bar for 30 minutes before shipment. KITOZER, CE, 10 year material warranty.
Flange ends are PN16 standard, matching industry CDUs and chillers. Grooved coupling ends support Victaulic-style quick assembly. Electropolished internal bore reduces fouling. Fittings include 90 and 45 degree elbows, equal and reducing tees, concentric reducers, and end caps. Each section is serialized and factory pressure-tested to 15 bar. Custom lengths and bends are available on request.
Applications
Stainless steel pipe is used for row-level supply and return loops connecting the CDU to rack manifolds, for primary loop piping between the chiller or dry cooler and the CDU, and for immersion cooling tank feed lines. Typical deployments include HPC data halls, AI training rooms, and industrial liquid cooling skids. Pre-bent sections simplify installation in raised-floor or overhead cable tray environments where on-site welding is restricted.
Common installations include row-level supply and return loops connecting CDU to rack manifolds, primary loop piping between chiller or dry cooler and CDU, and immersion cooling tank feed lines. Pre-bent sections simplify installation in raised-floor or overhead cable tray environments where on-site welding is restricted. Custom bent assemblies match the project layout exactly, reducing field fabrication.
Key Advantages
316L stainless resists corrosion in long-life glycol loops, eliminating the rust and sediment problems that plague black iron pipe. Electropolished internal bore minimizes fouling and pressure drop over decades. Pre-bent and pre-flanged sections reduce on-site welding, cutting installation labor by up to 60 percent. Factory pressure-tested to 15 bar ensures quality. Standard flange dimensions match industry CDUs and chillers. Traceable serial numbers support audit and maintenance records.
316L stainless resists corrosion in glycol loops. Electropolished bore minimizes fouling. Pre-bent sections cut on-site welding. Factory pressure-tested to 15 bar. Standard PN16 flanges. Traceable serial numbers. Custom lengths and bends available.
Installation and Maintenance
Route the pipe through raised floor or overhead tray using standard pipe supports every 1.5 m. Connect flanges with PN16 gaskets and stainless bolts. Pressure-test the completed loop at 1.5 times working pressure for 30 minutes before charging with glycol. Monthly: inspect flange joints for weepage and verify pipe support tightness. Quarterly: inspect insulation condition on cold pipes. Annually: inspect flange gaskets and replace any that show compression set. The pipe itself requires no internal maintenance.
Commissioning includes pressure test at 1.5 times working pressure for 30 minutes, leak check at each flange, and verification of pipe support tightness. After handover, baseline flange condition at nominal pressure. Recommended on-site spares: one PN16 gasket set, one flange bolt kit, and one insulating strip. The pipe itself requires no internal maintenance beyond periodic leak inspection.
Typical Configuration
A typical row loop uses DN32 supply and return piping running along the row ceiling or raised floor, with branch connections to each rack manifold. For a 10-rack row, the loop requires approximately 30 m of DN32 pipe, 4 elbows, 2 tees, and 2 flanged ends at the CDU. Pre-bent sections reduce field welding to flange connections only. Pipe supports are installed every 1.5 m, and insulation is applied to cold pipes to prevent condensation. All sections are factory pressure-tested to 15 bar and serialized.
Price
From $35 per meter for DN32. Custom bent assemblies quoted on request. Contact +86 13922289957 for project pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com