Table of Contents
ToggleProduct Overview
The KITOZER 100 kWh lithium battery cabinet is an integrated energy storage enclosure that houses LiFePO4 battery racks, a battery management system, a thermal monitoring chain, and a factory-approved fire suppression module in a single floor-standing cabinet. Designed for UPS backup, solar self-consumption, and peak-shaving applications, the cabinet combines high energy density with built-in safety. The BMS monitors cell voltage, temperature, and state of charge continuously, and reports status over CAN bus or Modbus TCP to the UPS, inverter, or building management system. The cabinet is delivered pre-wired and pre-tested on the factory floor, reducing commissioning time on site. The steel frame is reinforced to carry the full battery weight, and the front and rear lockable doors provide physical security and service access. Multiple cabinets can be paralleled to scale from 100 kWh to multi-megawatt installations without additional engineering.
Technical Specifications
Nominal energy 100 kWh, nominal voltage 384 V DC (120 cells in series), usable energy 90 percent, chemistry LiFePO4. Continuous discharge 50 kW, peak 100 kW for 30 seconds. BMS master plus slave architecture, cell balancing current 200 mA, protection functions include overvoltage, undervoltage, overcurrent, short circuit, over temperature, and under temperature. Communication: CAN, RS485 Modbus RTU, optional Modbus TCP or SNMP. Fire suppression: built-in aerosol or Novec-based module with thermal detection loop. Cabinet dimensions 2000 x 800 x 800 mm (H x W x D), IP20, color RAL 7035. Operating temperature 0 to 40 degrees Celsius. Self-consumption less than 100 W. Certification CE, IEC 62619, UN38.3. Warranty 5 years. Shipping weight 750 kg.
Application Scenarios
This battery cabinet is used in small and medium data centers as a UPS energy extension, in commercial buildings for peak shaving and demand charge management, in industrial plants for ride-through of critical processes, and in solar self-consumption systems for offices and factories. It pairs with 50 to 100 kVA UPS units or hybrid inverters. Multiple cabinets can be paralleled to scale from 100 kWh to multi-megawatt installations. The integrated fire suppression makes it suitable for indoor installation in leased data halls and office basements. It is also used in telecom base stations, hospital generator backup extension, and in islanded microgrids that combine solar, wind, and storage. The cabinet can be integrated with on-grid solar inverters to reduce peak demand charges and provide backup power during grid outages. It is a drop-in replacement for lead acid battery rooms where floor space is limited.
Key Advantages
LiFePO4 chemistry delivers a 6000-cycle life at 80 percent depth of discharge, far longer than lead acid. The integrated BMS protects cells and maximizes usable capacity. The factory-assembled and tested cabinet reduces on-site wiring errors. The built-in fire suppression and thermal detection satisfy indoor installation requirements. The compact 800 mm wide footprint delivers high energy density. Communication options allow seamless integration with UPS, EMS, and DCIM platforms. The cabinet is designed for parallel operation, so capacity can be expanded in 100 kWh steps as demand grows. The BMS logs every charge and discharge event, supporting service diagnostics and warranty claims. The LiFePO4 chemistry is inherently safer than other lithium chemistries, with lower risk of thermal runaway. The cabinet does not emit hydrogen gas during normal operation, so it can be placed in ordinary office rooms without dedicated battery ventilation.
Installation and Maintenance Recommendations
Install the cabinet on a level concrete floor with load capacity above 1000 kg per square meter. Provide dedicated ventilation per local electrical code. Keep ambient temperature between 20 and 25 degrees Celsius for maximum life. Do not install near direct sunlight or heat sources. Commissioning should be performed by trained personnel: check cell voltages, insulation resistance, and emergency stop function before energizing. Inspect the fire suppression module pressure gauge every six months and replace the module within its service interval. Calibrate BMS current sensor annually. Keep the front and rear aisles clear by at least 1200 mm. Do not open the high-voltage compartment without lockout-tagout procedures. The cabinet ships on a reinforced wooden pallet and includes a commissioning report and test certificate. The factory provides remote commissioning support and can dispatch field engineers for large projects. Spare BMS boards, fire suppression modules, and contactors are stocked as service parts. The cabinet is designed for parallel operation of up to 10 units, forming a 1 MWh battery cluster. Each cabinet has its own fire detection loop, so a fault in one cabinet does not affect the others. The BMS can be configured for peak shaving, demand response, or backup power modes through the touchscreen HMI. The cabinet carries a 5-year warranty on battery cells and a 2-year warranty on BMS and fire suppression components. Extended warranties up to 10 years are available on request.
Price
From $18,500/cabinet, including BMS, fire suppression, and commissioning support. Contact +86 13922289957 for parallel system pricing and EMS integration.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com