Table of Contents
ToggleProduct Overview
The KITOZER 100 kWh lithium battery cabinet is an integrated energy storage enclosure that houses LiFePO4 battery racks, a battery management system, a thermal monitoring chain, and a factory-approved fire suppression module in a single floor-standing cabinet. Designed for UPS backup, solar self-consumption, and peak-shaving applications, the cabinet combines high energy density with built-in safety. The BMS monitors cell voltage, temperature, and state of charge continuously, and reports status over CAN bus or Modbus TCP to the UPS, inverter, or building management system. The cabinet is delivered pre-wired and pre-tested on the factory floor, reducing commissioning time on site.
Technical Specifications
Nominal energy 100 kWh, nominal voltage 384 V DC (120 cells in series), usable energy 90 percent, chemistry LiFePO4. Continuous discharge 50 kW, peak 100 kW for 30 seconds. BMS master plus slave architecture, cell balancing current 200 mA, protection functions include overvoltage, undervoltage, overcurrent, short circuit, over temperature, and under temperature. Communication: CAN, RS485 Modbus RTU, optional Modbus TCP or SNMP. Fire suppression: built-in aerosol or Novec-based module with thermal detection loop. Cabinet dimensions 2000 x 800 x 800 mm (H x W x D), IP20, color RAL 7035. Operating temperature 0 to 40 degrees Celsius. Certification CE, IEC 62619, UN38.3. Warranty 5 years.
Application Scenarios
This battery cabinet is used in small and medium data centers as a UPS energy extension, in commercial buildings for peak shaving and demand charge management, in industrial plants for ride-through of critical processes, and in solar self-consumption systems for offices and factories. It pairs with 50 to 100 kVA UPS units or hybrid inverters. Multiple cabinets can be paralleled to scale from 100 kWh to multi-megawatt installations. The integrated fire suppression makes it suitable for indoor installation in leased data halls and office basements.
Key Advantages
LiFePO4 chemistry delivers a 6000-cycle life at 80 percent depth of discharge, far longer than lead acid. The integrated BMS protects cells and maximizes usable capacity. The factory-assembled and tested cabinet reduces on-site wiring errors. The built-in fire suppression and thermal detection satisfy indoor installation requirements. The compact 800 mm wide footprint delivers high energy density. Communication options allow seamless integration with UPS, EMS, and DCIM platforms.
Installation and Maintenance Recommendations
Install the cabinet on a level concrete floor with load capacity above 1000 kg per square meter. Provide dedicated ventilation per local electrical code. Keep ambient temperature between 20 and 25 degrees Celsius for maximum life. Do not install near direct sunlight or heat sources. Commissioning should be performed by trained personnel: check cell voltages, insulation resistance, and emergency stop function before energizing. Inspect the fire suppression module pressure gauge every six months and replace the module within its service interval. Calibrate BMS current sensor annually. Keep the front and rear aisles clear by at least 1200 mm. Do not open the high-voltage compartment without lockout-tagout procedures.
Price
From $18,500/cabinet, including BMS, fire suppression, and commissioning support. Contact +86 13922289957 for parallel system pricing and EMS integration.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com