KITOZER
KITOZER

KITOZER Lithium Battery Cabinet 2MWh Megabattery System

Product Overview

The KITOZER 2MWh megabattery system is a large-scale energy storage unit built inside a 40ft high-cube shipping container, designed for utility-scale and grid-connected storage projects. It integrates battery racks, a redundant master BMS, liquid thermal management, fire suppression, and power distribution into a single transportable unit. The system is optimized for long-duration energy storage, renewable energy integration, and grid services such as frequency regulation, voltage support, and peak shaving. Multiple containers can be clustered to form tens or hundreds of MWh storage plants, sharing a central PCS and energy management system.

Technical Specifications

Rated energy is 2MWh at 1500V DC nominal, with battery racks arranged in parallel strings. Usable capacity is 1.8MWh at 90 percent depth of discharge. Continuous power is 1MW, with peak support up to 2MW for 30 seconds. Cycle life exceeds 7,000 cycles at 80 percent depth of discharge and 25 degrees Celsius. Operating temperature range is minus 30 to 55 degrees Celsius, with redundant liquid thermal management maintaining 25 degrees Celsius inside the racks. The redundant master BMS monitors each cell, provides active balancing, and communicates via dual CAN and Modbus TCP. Safety features include smoke detection, gas venting, water mist fire suppression, manual DC disconnect, and thermal runaway propagation barriers. Enclosure is IP55 with C5-M anti-corrosion coating. The container includes auxiliary power, lighting, CCTV, and a fire-rated partition between battery and service areas.

Application Scenarios

This 2MWh system is deployed in utility-scale battery energy storage plants for grid stabilization, renewable energy integration, and capacity firming. Solar and wind farms pair the system with generation to store energy for periods of low production or high demand. Independent power producers use it for arbitrage, buying low and selling high, and for frequency regulation services. Large industrial parks and commercial campuses use clusters for peak shaving and backup power. Microgrid projects on islands, remote mines, and military bases use the system for reliable off-grid power. The container form factor allows rapid deployment and easy relocation as project needs change.

Advantages and Features

The 2MWh capacity in a single 40ft container maximizes energy density and reduces the number of units required for large projects. Redundant BMS and thermal management ensure high availability, with a single component fault not taking the container offline. The comprehensive fire suppression and gas venting system provides robust safety for grid-scale installations. Parallel operation allows flexible scaling from 2MWh to hundreds of MWh, and the Modbus TCP interface integrates with central PCS and energy management systems. KITOZER provides a cloud monitoring portal that aggregates data across all containers, enabling remote diagnostics, performance analytics, and predictive maintenance. The C5-M anti-corrosion coating ensures long life in coastal and industrial environments.

Installation and Maintenance Recommendations

Installation requires a reinforced concrete pad capable of supporting approximately 45 tons, adequate drainage, and a DC connection to the central PCS. The container must be grounded, and DC cables sized for the full discharge current with proper fusing. During commissioning, verify BMS communication on both redundant channels, test all protection functions, and configure the energy management system. Routine maintenance includes quarterly visual inspection, semi-annual terminal torque check, annual liquid loop inspection, and BMS firmware updates. The KITOZER monitoring platform tracks cell voltage imbalance, internal resistance, and temperature trends, predicting maintenance needs. For multi-container plants, implement a coordinated maintenance plan so that at least one full redundancy set remains online during service windows.

Reliability and Sustainability

The 2MWh megabattery system undergoes extended factory testing including 96 hours of charge and discharge cycling, liquid loop pressure tests, and redundant BMS communication verification. The container shell is load-tested for wind and seismic conditions, and the water mist fire suppression system is certified by an independent laboratory. Each battery rack is capacity-tested and matched for internal resistance. KITOZER provides complete as-built documentation including P&ID drawings, electrical schematics, and test reports. The LiFePO4 chemistry is non-toxic and fully recyclable. The 7,000-cycle life supports more than 15 years of daily cycling. A five-year warranty covers manufacturing defects, and the cloud monitoring platform aggregates data across all containers, enabling predictive maintenance for grid-scale plants. Redundant thermal management and BMS ensure high availability for mission-critical grid services.

Energy Impact

The 2MWh megabattery enables grid-scale renewable energy integration, storing solar and wind generation for dispatch during peak demand and reducing reliance on fossil-fuel peaker plants. The round-trip efficiency exceeds 95 percent. Redundant liquid thermal management minimizes auxiliary energy use while ensuring battery longevity. Over a 15-year service life, a single container can offset thousands of tons of carbon emissions. The cloud portal reports energy shifted, carbon avoided, and revenue from frequency regulation and arbitrage, helping project developers demonstrate environmental and financial returns to investors.

Price

From $185,000 per container, including redundant BMS, liquid thermal management, fire suppression, and one year of cloud monitoring. Contact KITOZER for multi-container plant design and PCS pairing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com