KITOZER Micro Module Single Row 20kW IT Room

Product Overview

The KITOZER single-row micro module is a compact, self-contained IT room solution designed for small and medium server rooms that need efficient containment without building a full modular hall. It combines up to six server racks, in-row precision cooling, a UPS cabinet, and a hot aisle containment enclosure into one neat row. The structure uses aluminum frames with polycarbonate or glass doors, creating a sealed hot aisle that improves cooling efficiency and reduces energy waste. The solution is ideal for branch offices, retail stores, factory floors, and small data closets that want enterprise-level containment at a fraction of the cost and space of a traditional raised-floor room.

Technical Specifications

Rated IT load is 20kW continuous across up to six 42U racks at 3 to 4kW per rack. Cooling uses one or two 12kW in-row precision air conditioners mounted at the end of the row, maintaining 24 degrees Celsius and 50 percent relative humidity. Power distribution includes a 32A single-phase or 63A three-phase input, a 20kVA online UPS cabinet with 10 minutes battery backup, and per-rack PDU metering. The KITOZER micro module controller provides a 7-inch touchscreen, monitoring temperature, humidity, smoke, door status, and electrical parameters, with Modbus TCP and SNMP connectivity. The containment frame is aluminum with transparent polycarbonate roof and doors, IP20 indoor rated.

Application Scenarios

This single-row micro module is perfect for small enterprise server rooms, retail branch IT closets, factory edge compute nodes, and small office network closets. It is also used in school computer rooms, bank branch server closets, and medical clinic IT equipment spaces. The compact footprint means it can fit in existing rooms with standard ceiling heights, and the transparent containment allows easy visual inspection of racks. It is particularly popular in markets where a full raised-floor room is too expensive or too large, but open-rack cooling is too inefficient.

Advantages and Features

The hot aisle containment design raises cold aisle temperature and improves cooling efficiency, with a target PUE below 1.60 in small rooms. The in-row air conditioner is placed directly next to the racks, eliminating long duct runs and hot spots. The aluminum frame is lightweight, easy to install, and can be disassembled and moved if the office relocates. The KITOZER controller provides local visualization and remote monitoring, with alarms sent by email or cloud dashboard. The transparent roof and doors allow technicians to see rack status without opening doors, reducing heat leakage and improving security. The solution is delivered as a pre-assembled kit, with installation typically completed in one day.

Installation and Maintenance Recommendations

Site preparation requires a level floor, a dedicated power feed, and network drops. The frame is assembled by two technicians in a few hours, and racks are rolled into position. During commissioning, verify PDU phasing, test UPS battery backup, and calibrate the temperature sensor. Routine maintenance includes monthly air filter cleaning on the in-row cooler, quarterly UPS battery check, and annual visual inspection of door gaskets and polycarbonate panels. The KITOZER controller logs alarms and events, helping the IT team identify recurring issues. Keep the front of the in-row cooler clear for air intake, and avoid blocking the hot aisle exhaust with boxes or equipment.

Reliability and Sustainability

The single-row micro module is factory-assembled and tested before shipment, with the containment frame, in-row cooler, and UPS cabinet all verified as a complete kit. KITOZER provides as-built drawings, test reports, and a spare parts list. The design service life is 15 years, with the in-row cooler and UPS rated for continuous operation. A five-year warranty covers manufacturing defects. The hot aisle containment design achieves a target PUE below 1.60 in small rooms, reducing fan energy compared with open rack layouts. The aluminum frame is lightweight and recyclable, and all electronics meet RoHS standards. The modular kit can be disassembled and relocated when the office moves, reducing waste and protecting the initial investment.

Energy Efficiency

The KITOZER controller tracks real-time power and temperature per rack, helping IT teams identify underutilized equipment. The hot aisle containment allows a higher cold aisle setpoint, reducing in-row cooler run time and fan energy. The compact UPS module operates at high efficiency across the load range, avoiding low-efficiency partial-load operation. Over a year, these measures typically reduce cooling electricity by 20 percent compared with an open rack layout. The controller also generates energy reports for building management and sustainability audits.

Contact KITOZER for a layout drawing and energy estimate based on your existing server room. The single-row design fits through standard doorways and requires no raised floor.

Price

From $12,500 per row, including containment frame, in-row cooler, UPS cabinet, and controller. Contact KITOZER for rack count and UPS sizing options.