Table of Contents
ToggleProduct Overview
The KITOZER triple-row micro module is a high-density containment solution that combines three rows of server racks with integrated in-row cooling, a central power wall, and a master monitoring system. It is designed for organizations that need up to 200kW of IT load in a compact footprint, without the cost of a full prefabricated building. The aluminum containment frame with glass doors and roof panels creates a sealed hot aisle, while in-row coolers placed between racks deliver cold air directly to server intakes. The solution is suitable for enterprise data centers, colocation cages, and cloud edge sites that want modular, efficient, and visually clean containment.
Technical Specifications
Rated IT load is 200kW continuous across up to 24 racks at 8 to 10kW average density. Cooling uses eight 30kW in-row precision air conditioners in N+2 redundancy, maintaining 24 degrees Celsius and 50 percent relative humidity. Power distribution includes a 500A three-phase main switchboard, 250kVA online UPS with 20 minutes battery autonomy, and overhead busway with per-rack metering. The KITOZER master controller provides a 15-inch touchscreen, 128 monitoring points, and remote access via web and mobile. Fire suppression uses gas clean agent with aspirating detection. Physical security includes card readers, door contacts, and CCTV. The containment frame is anodized aluminum with tempered glass, IP20 indoor rated.
Application Scenarios
This triple-row micro module is deployed by mid-size enterprises building private clouds, by colocation providers offering high-density cages, and by government agencies consolidating legacy server rooms. It is also suitable as a dedicated AI or analytics compute zone, as a regional data node for telecommunications operators, and as a disaster recovery hall for financial institutions. The compact footprint means it can fit in existing warehouse or plant space, and the glass containment provides a professional appearance for customer-facing data centers. It is particularly popular in markets where raised-floor construction is expensive but rack density is rising.
Advantages and Features
The sealed hot aisle and in-row cooling design delivers a target PUE below 1.35, reducing energy cost compared with traditional raised-floor rooms. The N+2 cooling redundancy ensures that even two cooler failures do not interrupt operations. Overhead busway allows rack additions in minutes, and per-rack metering enables accurate chargeback. The KITOZER master controller provides a unified view of power, cooling, and security, with automated reports for compliance. The aluminum frame is modular and can be extended by adding bays, protecting future expansion. Glass doors improve security by providing visual monitoring of rack access, and the modern aesthetic fits well in corporate and colocation environments.
Installation and Maintenance Recommendations
Site preparation requires a level floor with adequate load bearing, a 500A three-phase power feed, and fiber network termination. The frame is assembled by a KITOZER crew in one to two weeks, and racks are rolled into position. During commissioning, verify busway phasing, test UPS redundancy transfer, and calibrate all sensors. Routine maintenance includes monthly filter changes, quarterly battery tests, semi-annual cooling performance tuning, and annual fire suppression service. The KITOZER controller provides predictive alerts for fan wear, filter clogging, and battery degradation. For high-availability sites, maintain a spare parts kit on site and sign a service contract with guaranteed response times.
Price
From $128,000 per triple-row module, including containment frame, 250kVA UPS, N+2 in-row cooling, overhead busway, and factory FAT. Contact KITOZER for custom layouts and expansion planning.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com