Table of Contents
ToggleProduct Overview
The KITOZER MNS low voltage distribution cabinet is a type tested modular switchgear system for 400V industrial motor control centers, power distribution boards, and capacitor compensation panels. Based on the worldwide MNS standard, each cubicle uses a 25mm sheet steel modular frame, vertical wire ways, and withdrawable drawer units. KITOZER engineers the MNS system for high short circuit withstand and internal arc classification, making it suitable for continuous process industries where personnel safety and uptime are critical.
Technical Specifications
Rated voltage 400V, 50Hz, rated current up to 6300A main bus. Short time withstand 80kA for 1 second. Drawer units from 9E to 72E size, feeder MCCB up to 630A, motor starters up to 315kW. Automatic transfer switch panel, capacitor compensation panel, and feeder board available in the same frame. Protection degree IP4X front, IP2X rear. Internal arc classification AFLR 1 sec on request. Panel width 600, 800, 1000mm, depth 800 or 1000mm, height 2200mm. Standards IEC 61439-1 and -2, GB 7251, CE, type tested.
Application Scenarios
MNS cabinets are deployed in refineries, chemical plants, pulp and paper mills, mining facilities, and water treatment plants. They also serve as the main LV switchboard for large commercial complexes and as the MCC for conveyor, pump, and fan motor groups. The modular design supports step by step expansion as production lines grow.
Advantages and Features
Type tested system guarantees consistency across panels. Withdrawable drawers allow unit swap in under 5 minutes. Internal arc classification protects operators during fault events. KITOZER offers options including a motor protection relay with Modbus, an energy meter per feeder, and a SCADA gateway. The modular frame allows future retrofits without replacing the whole board.
Installation and Maintenance
Place panels on a flat plinth with 1500mm front clearance for drawer withdrawal. Connect horizontal and vertical busbars with torque specified in the manual. Bond all panels to the plant ground. Commissioning includes a pre energization insulation test, a drawer insertion and withdrawal cycle, and a protection relay test. Annual maintenance includes contactor contact inspection, heater function, and busbar torque check. KITOZER recommends a 10 year inspection of the main busbar and drawer contacts.
Price
From $2,480/panel. Contact +86 13922289957 for MNS MCC quote.