Integrated Micro-Module Data Center Options | KITOZER

Scope note: This page covers integrated micro-module options that can be specified with aisle containment. Physical containment architecture, sealing class and airflow design are documented on the dedicated containment page.

I. System Introduction

The modular cold and hot aisle containment system serves as the core infrastructure for airflow organization and environmental management in data center computer rooms. It uses an enclosed cold-hot air isolation design to organize airflow paths. Cooling utilization and room management performance are confirmed per project. Integrated with multiple subsystems including cabinets, aisle containment components, in-row air conditioners, power supply and distribution, environment monitoring, and security protection, the system features a modular architecture that supports rapid deployment, flexible expansion, and intelligent operation and maintenance. It can help manage data-center energy use (PUE confirmed per project), improve equipment operation reliability and energy efficiency ratio, and comply with the national “dual carbon” strategic goals and green development requirements of data centers.

Core Working Principle

Dual rows of cabinets are arranged face-to-face to form cold aisles and back-to-back to form hot aisles. After the cold aisles are enclosed, the system is designed to guide supply air into the contained aisle toward server inlets; performance is confirmed per project. The heated hot air flows back to the air conditioner return air side through the top of the hot aisles, realizing physical isolation of cold and hot airflow. This mechanism eliminates local hotspots thoroughly and greatly improves the overall cooling efficiency of the computer room.

II. System Composition

System ModuleCore ComponentsFunction Description
Aisle Containment SystemManual/automatic sliding glass doors, fixed/flip skylights, aisle frames, blanking panels, sealing stripsRealize physical isolation of cold and hot aisles, block airflow short circuits, and support automatic opening via fire linkage
Cabinet SystemStandard server cabinets (600/800mm width), equipment mounting rails, cable organizers, thermal blanking panelsBear IT equipment loads, optimize internal airflow paths, and eliminate internal cabinet hotspots
Cooling SystemIn-row air conditioners, air wall systems, airflow distribution devicesAdopt proximal cooling and precise air supply with temperature-control accuracy and cooling capacity confirmed per project
Power Supply & Distribution SystemIntelligent precision distribution cabinets, UPS modules, battery packs, PDUProvide high-efficiency power supply with redundant design and hot-swap support, achieving power conversion efficiency over 96%
Environment Monitoring SystemTemperature and humidity sensors, airflow sensors, smoke detectors, monitoring hosts, alarm devicesReal-time monitoring of environmental parameters with multi-channel alarms, shortening fault location time to 8 minutes
Security SystemAccess control (password/card/fingerprint/face recognition), video surveillance, electronic locksImplement aisle access authority management, safety protection and fire linkage control
Lighting SystemLED cool white lighting, human body induction control, emergency lightingRealize energy-saving intelligent lighting and ensure emergency lighting guarantee
(dual row hot aisle) system solution (1)

III. System Classification

1. Classification by Aisle Type

TypeFeaturesApplicable Scenarios
Cold Aisle Containment SystemEnclosed cold aisle with centralized cold air supply and open hot aislesMedium and low-density data centers, traditional computer room renovation, scenarios with a defined PUE target (confirmed per project)
Hot Aisle Containment SystemEnclosed hot aisle for centralized hot air discharge and open cold aislesHigh-density data centers and heat-concentrated areas requiring precise hot air backflow control
Dual Cold & Hot Aisle Containment SystemFully enclosed cold and hot aisles with complete airflow isolation and independent circulationHigh-density cabinets with a defined PUE target (confirmed per project)

2. Classification by Deployment Mode

TypeFeaturesApplicable Scenarios
Single-Row Aisle SystemSingle row of cabinets with single-side enclosure, simple structure and flexible deploymentSmall computer rooms, edge computing nodes, space-limited scenarios
Double-Row Aisle SystemDual rows of cabinets arranged face-to-face for excellent enclosure effect and high cooling efficiencySmall and medium-sized data centers, standard computer room construction with 12-48 cabinets
Multi-Row Aisle SystemCombined multi-row cabinets forming multiple cold and hot aisles with large-scale expansion supportLarge-scale data centers, cloud data centers and ultra-large-scale deployment scenarios

3. Classification by Intelligence Level

TypeFeaturesApplicable Scenarios
Basic SystemManual control, basic environmental monitoring without intelligent adjustmentBudget-limited small computer rooms and non-critical business scenarios
Intelligent SystemAutomatic control, intelligent environmental monitoring, remote management and fault early warningMedium-sized data centers and critical business scenarios requiring improved O&M efficiency
Smart SystemAI intelligent adjustment, load linkage control, energy consumption analysis and predictive maintenanceLarge-scale data centers, core business scenarios in finance and telecommunications, and green data center certification scenarios
(dual row hot aisle) system solution (2)

IV. System Configuration List (Brand: KITOZER)

4.1 Cold Aisle Containment System Configuration

No.Product NameModelBrandQuantityTechnical Specifications
1Standard Server CabinetKT-Z600/KT-Z800KITOZEROn-demand2000/2200mm height, 600/800mm width, 1100/1200mm depth, load capacity ≥1000kg, equipped with thermal blanking panels
2Manual Sliding Glass DoorKT-CG600/KT-CG800KITOZER2 sets per aisleTempered glass with thickness ≥8mm, DC-24V fire linkage core-pulling lock, manual opening force ≤50N
3Fixed Flip SkylightKT-CT600/KT-CT800KITOZER1 set per aisleFire-retardant material, automatic fusing opening function (72℃), fire linkage control support
4Aisle FrameKT-CK600/KT-CK800KITOZER1 set per aisleAluminum alloy material, modular design, 450mm higher than cabinet top, compatible with mainstream cabinet layouts
5Sealing Blanking PanelKT-MB19/KT-MB24KITOZEROn-demand19/24-inch size, ABS material, used for sealing unused cabinet U positions to eliminate turbulent flow
6Sealing StripKT-MS10KITOZEROn-demandEPDM rubber material, temperature resistance range: -40℃~120℃, excellent sealing performance

4.2 Cooling & Power Supply Distribution System Configuration

No.Product NameModelBrandQuantityTechnical Specifications
1In-Row Air ConditionerKT-LK20/KT-LK30KITOZER1-2 units per aislecooling capacity and temperature-control accuracy confirmed per project, EC variable frequency fan, variable frequency compressor, hot-swap support
2Intelligent Precision Distribution CabinetKT-PD630KITOZER1 unit per aisle630A input, 16-channel C13/C19 output, hot-swap support, conversion efficiency >96%, built-in monitoring module
3UPS Power ModuleKT-UPS10/KT-UPS20KITOZEROn-demandPower-module capacity, redundancy, and conversion efficiency confirmed per project
4Battery PackKT-BT12KITOZEROn-demand12V/100Ah valve-regulated lead-acid battery, 16/32 units per UPS, hot-swap support
5Intelligent PDUKT-PDU16KITOZER1-2 units per cabinet16-channel output, current monitoring, remote control and overload protection functions

4.3 Environment Monitoring & Security System Configuration

No.Product NameModelBrandQuantityTechnical Specifications
1Environment Monitoring CollectorKT-DH800KITOZER1 unit per aisle16×RS485, 12×DI, 4×DO, 2×LAN ports, dual power supply, Modbus protocol support
2Temperature & Humidity SensorKT-TH100KITOZER2-4 units per aisleSensor range and accuracy confirmed per project
3Airflow SensorKT-QF100KITOZER2 units per aisleMeasuring range 0~10m/s, accuracy ±0.1m/s, for real-time monitoring of aisle airflow velocity
4Access ControllerKT-MJ800KITOZER1 unit per aisleSupports password, card, fingerprint and face recognition composite verification, storage of ≥100,000 records
5Alarm DeviceKT-GJ800KITOZER1 set per aisleSound & light alarm, multi-channel remote notification via WEB, email, SMS and WeChat
6LED Lighting SystemKT-LM600KITOZER1 set per aisleLED cool white light, power ≤20W, human body induction control and emergency lighting function
(dual row hot aisle) system solution (3)

V. System Schematic Diagram

5.1 Airflow Organization Schematic of Cold Aisle Containment System

┌─────────────┐      ┌─────────────┐
│  Server Cabinet  │      │  Server Cabinet  │
│ (Face-to-Face Layout) │      │ (Face-to-Face Layout) │
└──────┬──────┘      └──────┬──────┘
       │                     │
       ▼                     ▼
┌─────────────┐      ┌─────────────┐
│  Cold Aisle Space  │◄─────┤  In-Row Air Conditioner │
│ (Enclosed Design)  │      │ (Proximal Cooling)  │
└──────┬──────┘      └──────┬──────┘
       │                     │
       ▼                     ▼
┌─────────────┐      ┌─────────────┐
│  Hot Aisle Space  │─────►│  Air Return Outlet     │
│ (Open/Enclosed) │      │ (Hot Air Backflow)│
└─────────────┘      └─────────────┘

5.2 System Topology Diagram

┌─────────────────────────────────────────────────┐
│        Modular Cold & Hot Aisle System         │
│ ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌─────────┐ │
│ │Aisle Containment│ │ Cabinet Group │ │ Cooling System │ │ Power Distribution │ │
│ └─────────┘ └─────────┘ └─────────┘ └─────────┘ │
│ ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌─────────┐ │
│ │Environment Monitoring│ │ Security System │ │ Lighting System │ │ Management Platform │ │
│ └─────────┘ └─────────┘ └─────────┘ └─────────┘ │
└─────────────────────────────────────────────────┘
        │              │              │
        ▼              ▼              ▼
┌─────────────┐  ┌─────────────┐  ┌─────────────┐
│  Fire System Linkage  │  │  Remote O&M Center  │  │  Energy Consumption Analysis System  │
└─────────────┘  └─────────────┘  └─────────────┘

VI. Core Technical Parameters

6.1 Aisle Containment System Parameters

Parameter ItemTechnical IndexRemark
Aisle Width1200-1500mmAdapt to dual-row layout of 600/800mm wide cabinets
Aisle Height2050-2400mm450mm higher than cabinet top, balancing ergonomics and equipment hoisting
Glass Door SpecificationTempered glass thickness ≥8mm, light transmittance ≥90%Comply with GB15763.2 impact resistance standard
Skylight Opening ModeAutomatic flip + manual opening, manual opening angle ≥90°72℃ fusing automatic opening for fire linkage
Sealing PerformanceCold air leakage rate ≤5%15-20% lower than traditional open computer rooms
Frame MaterialAluminum alloy 6063-T5 with anodized surfaceStrong corrosion resistance
Protection GradeIP20Prevent human contact with live parts

6.2 Cooling System Parameters

Parameter ItemTechnical IndexRemark
Cooling Capacity Range5-41kW, support multi-module parallel expansionIn-row air conditioner customized configuration
Temperature Control AccuracyConfirmed per projectComply with ASHRAE data center environmental standards
Air Supply Temperature18-22℃Comply with T/GDEA 002-2023 standard
Air Return Temperature28-33℃Optimize cooling efficiency
Fan TypeEC variable frequency fan, 0-100% speed regulationEnergy-saving efficiency is confirmed per project
Compressor TypeCompressor type and COP confirmed per projectSoft start support
Noise LevelConfirmed per projectMeet computer room noise standards

6.3 Monitoring & Security System Parameters

Parameter ItemTechnical IndexRemark
Temperature & Humidity MonitoringTemperature and humidity range confirmed per projectReal-time monitoring and over-limit alarm
Access Control SystemMulti-factor verification, storage of ≥100,000 recordsData storage duration ≥1 year
Alarm ModeSound & light alarm + remote notification (email/SMS/WeChat)Fault location time ≤8 minutes
Communication InterfaceRS485, DI/DO, LAN, USBSupport Modbus, SNMP protocols
Power Supply ModeDC12V/24V, dual power redundancyEnsure stable system operation
(dual row hot aisle) system solution (4)

VII. Application Scope

7.1 Industry Application Fields

IndustryApplication ScenariosCore Requirements
Internet & Cloud ComputingLarge data centers, edge computing nodesHigh-density deployment; PUE and expansion time confirmed per project
Financial IndustryBank data centers, securities trading systemsHigh reliability, redundant design, fast fault recovery
Telecom OperatorsCore computer rooms, aggregation computer roomsLarge-scale deployment, remote O&M, energy consumption optimization
Government InstitutionsGovernment cloud platforms, e-government systemsSafety and reliability, green energy saving, policy compliance
Energy IndustryPower dispatch centers, new energy monitoring systemsHarsh environment adaptability, strong anti-interference ability
Medical IndustryMedical data centers, image storage systemsConstant temperature and humidity, data security, 24-hour operation
Education & ResearchUniversity data centers, scientific computing platformsHigh-performance computing, flexible expansion, cost control

7.2 Scenario Application Classification

Scenario TypeFeaturesRecommended Solution
New Data CenterFull planning and construction from scratchDual cold & hot aisle containment, smart configuration; PUE confirmed per project
Computer Room RenovationUpgrade based on existing facilities with space constraintsCold aisle containment, modular rapid deployment
High-Density AreaHigh power density with hotspot issues (density confirmed per project)Hot aisle containment + in-row air conditioner for precise cooling
Edge Computing NodeMiniaturized, flexible deployment, unattended operationSingle-row aisle system, intelligent configuration & remote management

VIII. Core Product Advantages

8.1 Core Technical Advantages

  • Precise Airflow Control: The enclosed aisle is designed to isolate cold and hot air streams. Airflow isolation performance is confirmed per project. PUE and energy saving versus a traditional room are confirmed per project.
  • Modular Architecture: Interchangeable component design supports rapid deployment (deployment time confirmed per project) and flexible later expansion, effectively reducing initial investment and operation & maintenance costs.
  • Intelligent Environmental Management: AI algorithm adjusts cooling capacity and airflow; temperature-control accuracy is confirmed per project. Fault-location time and O&M efficiency are confirmed per project.
  • High-Reliability Design: Adopts redundant power supply, fire linkage and multi-layer security protection, helping reduce downtime risk. MTTR is confirmed per project.
  • Green Energy-Saving Certification: Certification support is confirmed per project when a bid requires it.

8.2 Full Lifecycle Value

StageValue ReflectionQuantitative Index
Design StageShorten design cycle and reduce on-site survey workDesign time and drawing standardization are confirmed per project
Construction StageRapid deployment and shortened construction cycleInstallation efficiency and deployment time confirmed per project
Operation StageEnergy saving and consumption reduction, lower O&M costsLarge data centers save 21 million kWh annually, 50% less O&M manpower
Expansion StageSmooth expansion without business interruption80% shorter expansion time, online hot-swap support
Decommissioning StageComponent recycling and waste reductionComponent recycling rate ≥90%, compliant with circular economy standards
(dual row hot aisle) system solution (5)

IX. Reference Parameters

9.1 Aisle Containment System Reference Parameters

Parameter ItemBid RequirementsCompliance Standard
Aisle FrameAluminum alloy modular design, 450mm higher than cabinet top, compatible with 600/800mm wide cabinetsT/GDEA 002-2023 Clause 5.2
Glass DoorTempered glass thickness ≥8mm, light transmittance ≥90%, DC-24V fire linkage lock, opening force ≤50NGB15763.2 Standard
SkylightFire-retardant material, 72℃±2℃ fusing automatic opening, fire linkage control, opening angle ≥90°GB50116-2013
Sealing PerformanceCold air leakage rate ≤5%, airflow velocity uniformity deviation ≤10%T/GXDSL 003-2025
Protection GradeComponent protection grade ≥IP20, glass door impact resistance up to national standardGB4208-2017

9.2 Cooling and Monitoring System Reference Parameters

Parameter ItemBid RequirementsCompliance Standard
Cooling CapacityIn-row air conditioner cooling capacity and expansion confirmed per projectASHRAE Data Center Standard
Temperature Control AccuracyCold aisle temperature and regional difference confirmed per projectT/GDEA 002-2023 Clause 5.3
Monitoring SystemSupport multi-parameter monitoring, ≥5 alarm modes, response time ≤3 secondsGB50174-2017
Redundancy DesignN+1 redundancy for power supply and cooling systems, no single point of failureUptime Tier Standard
Energy Saving IndexPUE, cooling COP, and fan type confirmed per projectNational Energy-Saving & Carbon Reduction Guidelines

9.3 Safety and Reliability Reference Parameters

Parameter ItemBid RequirementsCompliance Standard
Fire LinkageFire signal linkage, skylight opening time ≤3s, automatic glass door unlockingGB50116-2013
Access Control SystemMulti-factor authentication, 100,000+ record storage, data retention ≥1 yearGB50348-2018
Seismic PerformanceAisle frame seismic grade ≥8, cabinet seismic grade ≥9GB50011-2010
Service LifeMain components service life ≥10 years, MTBF≥100,000 hoursData Center Infrastructure Reliability Standard
Environmental ProtectionRoHS compliant, noise ≤60dB, national first-class energy efficiencyGB/T 2887-2011
(dual row hot aisle) system solution (6)

X. Customized Solution Packages

10.1 New Data Center Solution

Solution Overview: Adopt dual cold and hot aisle containment system, integrate power supply, cooling, monitoring and security subsystems to build a green, efficient, intelligent and reliable data center infrastructure.

Core Configuration:

  • Aisle System: Dual cold & hot aisle containment, aluminum alloy frame, automatic sliding glass door, fixed flip skylight
  • Cooling System: In-row air conditioner and air-wall capacity confirmed per project
  • Power Supply: Intelligent precision distribution cabinet + UPS module and battery redundancy confirmed per project
  • Monitoring System: Smart environment monitoring, AI predictive maintenance, multi-channel alarm
  • Security System: Face recognition access control + video surveillance + electronic lock with multi-level authority management

Implementation Steps: 1. BIM+CFD simulation for layout optimization; 2. Foundation construction and equipment positioning; 3. Multi-system integration and commissioning; 4. Performance testing and acceptance; 5. Long-term remote O&M support

Expected Effect: PUE, cooling efficiency, O&M cost, and recovery time are confirmed per project

10.2 Computer Room Renovation Solution

Solution Overview: Upgrade existing computer rooms with cold aisle containment system to eliminate hotspot problems, improve cooling efficiency and reduce energy consumption without business interruption.

Core Configuration:

  • Aisle System: Cold aisle containment, manual sliding glass door, fixed flip skylight and sealing blanking panels
  • Cooling System: In-row air conditioner capacity confirmed per project, linked with existing cooling equipment
  • Monitoring System: Intelligent environment monitoring with temperature, humidity and airflow monitoring & remote alarm
  • Power Optimization: Add intelligent PDU for energy consumption monitoring and remote control

Implementation Steps: 1. Current situation assessment and hotspot detection; 2. Modular customized design; 3. Rapid on-site assembly; 4. System linkage debugging; 5. Effect verification and parameter optimization

Expected Effect: PUE, hotspot control, energy saving, and renovation method are confirmed per project

10.3 High-Density Area Solution

Solution Overview: Targeting high-density areas (power density confirmed per project), adopt hot aisle containment + high-power in-row air conditioner scheme