Table of Contents
ToggleProduct Overview
The KITOZER 200kW modular data center is a high-efficiency prefabricated IT hall designed for organizations that need enterprise-grade availability with accelerated deployment. It combines air-cooled and indirect air-side economizer cooling, a modular UPS system, and a federated monitoring platform into a standardized building block that can be delivered to site and commissioned in weeks. The unit is suitable for indoor plant rooms or covered outdoor yards, and can be clustered to form a megawatt-scale data center campus. The design emphasizes low PUE, flexible expansion, and compliance with international uptime standards.
Technical Specifications
Rated IT load is 200kW continuous, supporting up to 32 racks at 6 to 8kW average density. Cooling uses six 40kW in-row precision air conditioners with N+1 redundancy, supplemented by an air-side economizer for cool climate operation. Power distribution includes a 500A three-phase main switchboard, 250kVA modular UPS with 20 minutes battery autonomy, and overhead busway with per-rack metering. The KITOZER master controller provides a 21-inch HMI, 160 monitoring points, and federated management across multiple modules. Fire suppression uses gas clean agent with aspirating detection and emergency exhaust. Physical security includes biometric access, mantrap, and CCTV with NVR. Operating range is 5 to 40 degrees Celsius ambient for indoor installation.
Application Scenarios
This 200kW module is deployed by large enterprises building private clouds, by colocation providers launching mid-size campuses, and by government agencies consolidating legacy data centers. It is also used as a dedicated AI or analytics compute hall, as a regional data node for telecommunications operators, and as a temporary capacity solution during permanent data center construction. Healthcare systems use it as a secure compute hall for medical imaging and electronic health records, while financial institutions deploy it as a highly available tier for core banking and risk analytics. The unit is particularly suited to climates where free cooling can reduce energy cost for much of the year.
Advantages and Features
The combination of in-row cooling and air-side economizer delivers a target PUE below 1.35 in temperate climates, significantly reducing energy cost. Modular UPS allows power capacity to be added one 25kW module at a time, matching IT load growth and avoiding stranded capacity. The busway design means rack additions take minutes, and per-rack metering enables accurate chargeback for multi-tenant environments. KITOZER federated management provides a single pane of glass across dozens of modules, with automated reports for energy, availability, and capacity. The panels are constructed from recyclable steel with rock wool insulation, supporting sustainability goals. The unit also supports on-site battery energy storage and solar PV integration for resilient, low-carbon operation.
Installation and Maintenance Recommendations
Site preparation requires a reinforced concrete floor or plinth, a 500A three-phase utility feed, and fiber network termination. Modules are delivered in sections and assembled on site by a KITOZER team, typically within two to three weeks. During commissioning, verify busway phasing, test UPS redundancy transfer, and calibrate all sensors. Routine maintenance includes monthly filter changes, quarterly battery tests, semi-annual economizer damper calibration, and annual fire suppression service. The KITOZER controller provides predictive alerts for fan wear, filter clogging, and battery degradation, allowing planned interventions. For high-availability sites, maintain a spare parts kit on site and sign a service contract with guaranteed response times.
Reliability and Sustainability
The 200kW module undergoes 72 hours of factory testing under combined load, with all UPS modules, economizer dampers, and cooling units verified before shipment. KITOZER provides complete as-built documentation and the assembly complies with CE, IEC, and ISO standards. The design service life is 20 years, with N+1 redundancy on all critical systems. A five-year warranty covers manufacturing defects, and extended service contracts include on-site spare parts storage and guaranteed response times. The combination of in-row cooling and air-side economizer achieves a target PUE below 1.35, significantly reducing energy use. The panels are recyclable steel, and all electronics meet RoHS standards. Optional battery energy storage and solar PV integration enable renewable-powered operation, supporting corporate carbon reduction goals over the 20-year service life.
Energy Efficiency
The KITOZER federated DCIM provides real-time energy usage reports per module and per rack, enabling detailed chargeback and capacity planning. The air-side economizer uses outside air for free cooling during cooler months, reducing chiller run time and electricity use. Modular UPS maintains high efficiency even at partial load, avoiding the efficiency penalties of oversized traditional UPS systems. Customers can set power capping policies to limit rack consumption during peak tariff periods. These features typically reduce annual energy cost by 25 to 35 percent compared with conventional data halls.
Price
From $158,000 per module, including 250kVA modular UPS, N+1 cooling, busway, and factory FAT. Contact KITOZER for campus design and energy modeling.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com