Table of Contents
ToggleI. System Introduction
1.1 System Overview
KITOZER Modular Hot & Cold Aisle Containment System (Cold Aisle Access Control) is an integrated solution of high-efficiency airflow management and physical security tailor-made for modern data centers. It separates hot and cold airflow via physical containment and integrates intelligent access control, improving cooling efficiency while guaranteeing computer room safety. Featuring modular construction, the system supports flexible expansion and rapid deployment, compatible with all standard server cabinets and air conditioning units. It applies to both new-build data centers and legacy computer room retrofits, effectively cutting down PUE and boosting operation & maintenance efficiency.
1.2 Working Principle
Following the principle of separated ordered circulation of hot and cold air, the system physically encloses cold aisles to deliver concentrated cold air to the front side of rack-mounted equipment; hot air is exhausted from cabinet rear into hot aisles and recycled by air conditioning to form optimized airflow circulation. The cold aisle access control system enables precise personnel access management, paired with environmental monitoring and fire alarm linkage to maximize cooling efficiency and minimize cold air loss without compromising staff safety.
1.3 Core Benefits
- Energy Saving & Consumption Reduction: Eliminates mixed cold-hot air loss to lower PUE below 1.3 (conventional computer rooms normally register PUE from 1.8 to 2.2)
- Controllable Safety: Multi-level access authorization, real-time access logging, automatic door release via fire linkage for emergency protection
- Intelligent Operation: Built-in environmental monitoring, remote control and data analytics to streamline maintenance
- Flexible Scalability: Modular design allows on-demand capacity expansion to fit data centers of all sizes
- Extended Equipment Lifespan: Stable ambient temperature cuts failure rate of servers and prolongs service life

II. System Composition
KITOZER Modular Hot & Cold Aisle Containment (Cold Aisle Access Control) System consists of five core subsystems working collaboratively to realize full-spectrum airflow management and security control.
| Subsystem | Key Components | Function Description |
|---|---|---|
| Aisle Containment System | Aluminum frames, tempered glass end doors, openable skylights, sealing fittings | Physically seals cold aisles to reduce cold leakage with clearance gap ≤2mm |
| Access Control System | Access controller, card reader, electromagnetic lock, exit button, management software | User authorization, access record storage, real-time monitoring & abnormal alarm |
| Environmental Monitoring System | Temperature & humidity sensors, barometric pressure sensors, smoke detectors, display screen | Real-time collection of aisle environmental indicators for data support and early warning |
| Intelligent Linkage System | Fire linkage module, AC control interface, lighting control system | Auto-open skylights/doors upon fire signal; adjusts air conditioner operation based on ambient temperature |
| Power Supply & Management System | Dedicated power supply, network switch, management server, monitoring terminal | System power guarantee, data transmission, centralized management and remote O&M |
III. System Classification
3.1 By Aisle Layout
| Category | Features | Applicable Scenarios |
|---|---|---|
| Single-row Cold Aisle | Single-side cabinet layout with opposite side open, simple structure & low cost | Small computer rooms, edge computing nodes, space-limited sites |
| Double-row Cold Aisle | Opposite dual-row cabinets forming fully enclosed aisle with superior cooling efficiency | Mid-to-large data centers, high-density computer rooms, newly-built projects |
| Full Hot & Cold Aisle Containment | Full enclosure of both hot and cold aisles for precise airflow control and minimal PUE | Hyper-scale data centers, high-power-density computer rooms, green data center certification projects |
3.2 By Door Type
| Category | Structural Features | Advantages |
|---|---|---|
| Manual Sliding Door | Aluminum frame + tempered glass, threshold-free bottom with dual-side handles | Low cost & easy maintenance for low-foot-traffic areas |
| Automatic Sliding Door | Motor-driven with top sliding rail, infrared induction & fire linkage | Smooth passage for high-frequency access with multiple unlocking modes |
| Folding Door | Multi-panel foldable design for footprint saving | Narrow aisle deployment to maximize room space utilization |
| High-speed Roller Shutter | Fast open/close, superior sealing and wind resistance | Large-scale data centers requiring high tightness and heavy personnel flow |
3.3 By Access Control Identification Mode
| Category | Recognition Method | Security Rating | Applicable Scenarios |
|---|---|---|---|
| Card-based Access | IC/ID Card Swipe | ★★★☆☆ | General computer rooms with basic security requirements |
| Password Access | Keypad Password Input | ★★★☆☆ | Auxiliary verification & temporary authorized entry |
| Biometric Access | Fingerprint / Facial Recognition | ★★★★★ | Core equipment rooms & high-security restricted zones |
| Multi-factor Access | Card+Password / Biometrics+Card | ★★★★☆ | Critical data center zones with hierarchical security governance |

IV. System Configuration List (Brand: KITOZER)
4.1 Standard Bill of Materials for Double-row Cold Aisle
Aisle Containment System
| No. | Item | Model | Specifications | Unit | Qty | Remark |
|---|---|---|---|---|---|---|
| 1 | Aluminum Frame | KITOZER-KL-01 | 2.0mm thick, anodized for outstanding corrosion resistance | Meter | As required | Matches standard cabinet height |
| 2 | Tempered Glass End Door | KITOZER-KM-02 | 5mm full-transparent tempered glass with aluminum frame, threshold-free design | Set | 2 | Incl. sealing strips & handles |
| 3 | Openable Fire Skylight | KITOZER-KT-03 | Fire-retardant material, fusible auto-opening with fire linkage | Set | Per aisle length | 1 set every 2 meters |
| 4 | Sealing Accessories | KITOZER-KF-04 | EPDM sealing strip with auto-lifting bottom seal | Set | As required | Clearance ≤2mm |
Access Control System
|5|Access Controller|KITOZER-KC-05|TCP/IP communication, single-door bidirectional control; stores 20,000 user cards & 100,000 access logs|Unit|1|Supports remote management|
|6|Card Reader|KITOZER-KR-06|IC/ID compatible, 5~10cm induction range, waterproof & dustproof|Pc|2|One each for indoor & outdoor|
|7|Electromagnetic Lock|KITOZER-KL-07|DC12V, holding force ≥280kg, fail-safe unlock on power cut|Pc|2|Customized to door specification|
|8|Exit Button|KITOZER-KB-08|Waterproof design with normally open contact|Pc|2|One each for indoor & outdoor|
|9|Access Management Software|KITOZER-KS-09|Authorization setup, log query & alarm linkage|Set|1|Windows OS compatible|
Environmental Monitoring System
|10|Temp & Humidity Sensor|KITOZER-KW-10|Temp: -10℃~+60℃; Humidity:0~100%RH|Pc|3|Installed at 1/4,1/2,3/4 aisle length|
|11|Differential Pressure Sensor|KITOZER-KQ-11|Range:-50~+50Pa, Accuracy±1Pa|Pc|1|Top center of aisle|
|12|7-inch Touch Screen|KITOZER-KD-12|Real-time data display & manual skylight/door control|Pc|1|Mounted on end door frame|
Intelligent Linkage System
|13|Fire Linkage Module|KITOZER-KX-13|Dry contact input for fire signal docking|Pc|1|Connects to building fire alarm system|
|14|Lighting Control System|KITOZER-KZ-14|Motion sensing, auto-off delay & energy-saving mode|Set|1|Full aisle lighting administration|
Power & Management System
|15|Special Power Supply|KITOZER-KP-15|DC12V 5A with overvoltage & overcurrent protection|Pc|1|Powers access controllers and sensors|
|16|POE Network Switch|KITOZER-KS-16|8-port Gigabit POE switch|Pc|1|Data transmission & device power supply|
|17|Integrated Management Platform|KITOZER-KM-17|Combines environmental monitoring & access control, remote web access|Set|1|Incl. server license|
4.2 Optional Expansion Configuration
| No. | Item | Model | Specifications | Application |
|---|---|---|---|---|
| 18 | Automatic Sliding Door Operator | KITOZER-KD-18 | DC24V, adjustable opening speed 0.5~1.0m/s | High-traffic access areas |
| 19 | Facial Recognition Terminal | KITOZER-KR-19 | 4MP camera, 0.5~2m recognition distance, ≥99.99% accuracy | High-security restricted zones |
| 20 | HD Surveillance Camera | KITOZER-KC-20 | POE powered,1080P, infrared night vision | 24/7 monitoring at aisle entrances |
| 21 | Emergency Escape Release Device | KITOZER-KS-21 | Mechanical manual release + fire auto-unlock | All aisle end doors for personnel emergency evacuation |
| 22 | Environment Data Collector | KITOZER-KD-22 | 8-channel sensor input, RS485 bus communication | Large-scale data center multi-aisle centralized monitoring |

V. System Schematic Diagram
5.1 System Architecture
┌─────────────────────────────────────────────────────────┐
│ Data Center Central Management Platform │
└───────────────────────────┬─────────────────────────────┘
│
┌───────────────┴───────────────┐
│ Regional Area Controller │
└───────────────┬───────────────┘
│
┌───────────────┴───────────────┐
│ KITOZER Cold Aisle System │
└───────────────┬───────────────┘
│
┌───────────┬───────────┬───────────┬───────────┬───────────┐
│Aisle │Access │Env. │Intelligent│Power │
│Containment│Control │Monitoring│Linkage │Management │
└───────────┴───────────┴───────────┴───────────┴───────────┘
│ │ │ │ │
┌─────────▼─────┐ ┌───▼─────┐ ┌───▼─────┐ ┌───▼─────┐ ┌───▼─────┐
│Frame/End Door/│ │Controller/│ │Temp/Hum/│ │Fire Link/│ │Power Pack/│
│Skylight/Seal │ │Reader/E-lock│ │Pressure/Smoke│ │AC/Light Ctrl│ │POE Switch/SW│
└───────────────┘ └─────────┘ └─────────┘ └─────────┘ └─────────┘
5.2 Airflow Distribution Diagram
┌─────────────────────────────────────────────────────────┐
│ Enclosed Cold Aisle │
│ ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌─────────┐ │
│ │Rack 1 │ │Rack 2 │ │Rack3 │ │Rack4 │ │
│ │Cold Inlet│ │Cold Inlet│ │Cold Inlet│ │Cold Inlet│ │
│ │Hot Outlet│ │Hot Outlet│ │Hot Outlet│ │Hot Outlet│ │
│ └─────────┘ └─────────┘ └─────────┘ └─────────┘ │
│ │
│ ←←←←←←← Cold Air Supply (Underfloor Airflow) →→→→→→ │
└─────────────────────────────────────────────────────────┘
↑ ↑
│ │
┌───────┴───────┐ ┌─────────┴─────────┐
│ Aircon Unit │◄──────────────────│ Open Hot Aisle │
│ (Air Return)│ │ │
└───────────────┘ └───────────────────┘
5.3 Access Control Logic Diagram
┌─────────────┐ ┌─────────────┐ ┌─────────────┐
│Central Mgmt │────▶│TCP/IP Access│────▶│Card/Bio │
│Software │ │Controller │ │Recognition │
└─────────────┘ └─────────────┘ └─────────────┘
▲ ▲ ▲
│ │ │
┌───────┴───────┐ ┌────┴────┐ ┌────┴────┐
│Electromagnetic│◀────▶│Exit │ │Identity │
│Lock & Door Status│ │Button │◀──────▶│Verification│
└───────────────┘ └─────────┘ └────────────┘
▲
│
┌───────┴───────┐
│Fire Alarm Input│
│Emergency Unlock│
└───────────────┘
VI. Product Technical Specifications
6.1 Aisle Containment System Specs
| Parameter | Technical Index | Remark |
|---|---|---|
| Frame Material | ≥2.0mm aluminum alloy with anodized finish | Excellent corrosion resistance, ≥15-year service life |
| End Door Material | 5mm full-transparent tempered glass + aluminum frame | ≥90% light transmittance, superior impact resistance |
| Sealing Performance | EPDM strip + auto-lifting bottom seal | Gap ≤2mm to reduce cold loss |
| Skylight Feature | Fire retardant, fusible link activates at 72℃ | Auto open upon fire alarm |
| Applicable Aisle Width | 1200~1800mm | Matches standard cabinet pitch |
| End Door Height | 2050mm | Ergonomic & convenient for equipment hoisting |
| Installation Mode | Ceiling suspended / floor mounted | Adapts diversified computer room structures |
6.2 Access Control System Specs
| Parameter | Technical Index | Remark |
|---|---|---|
| Controller | Single-door bidirectional control over TCP/IP | 20,000 card capacity & 100,000 access logs |
| Recognition Mode | IC/ID Card, Password, Fingerprint, Facial, Multi-factor Auth | Supports mixed verification |
| Communication | TCP/IP, Baud rate:115200bps | Real-time remote data & management |
| Power Input | DC12V ≤2A | Standard security power compatible |
| Door Hold Delay | Adjustable 1~600s | Customized for various on-site needs |
| Operating Temp | -10℃~+60℃ | Wide-range computer room environment adaption |
| Ingress Rating | Card Reader IP54; Controller IP30 | Dustproof & splash-proof |
| Alarm Function | Forced entry, door ajar & overtime open alert | Multi-scenario abnormal monitoring |
6.3 Environmental Monitoring Specs
| Parameter | Technical Index | Remark |
|---|---|---|
| Temperature Test | -10℃~+60℃, Accuracy ±0.5℃ | Real-time aisle thermal tracking |
| Humidity Test | 0~100%RH, Accuracy ±3%RH | Anti-condensation for IT equipment safety |
| Differential Pressure | -50~+50Pa, Accuracy ±1Pa | Maintains positive aisle pressure at 5~10Pa |
| Display Terminal | 7-inch color touch screen 800×480 | Live parameter & system status visualization |
| Data Storage | Min.30-day local storage + optional cloud backup | Historical data archiving & trend analysis |
| Sampling Rate | 1 reading per second | Instant response to ambient fluctuation |

VII. Application Scope
7.1 Industrial Deployment & Recommended Configuration
| Industry | Operation Characteristics | Recommended Solution |
|---|---|---|
| Internet IDC | High power density, heavy staff flow, 7×24hr continuous run | Full double-row cold aisle + auto sliding door + facial recognition access |
| Financial Data Center | Top-tier security, high uptime, disaster recovery demand | Full hot&cold containment + biometric access + multi-level authorization |
| Government & Public Institution | Controlled budget, limited maintenance staff, high reliability | Single-row cold aisle + card access + remote management |
| Cloud Computing Hub | Large-scale phased rollout & modular rapid expansion | Standard modular cold aisle + centralized management platform |
| Edge Computing Node | Compact footprint, unattended remote operation | Compact integrated cold aisle + smart access + all-in-one environment monitoring |
| Enterprise On-premise DC | Medium scale, mixed IT load & expandable layout | Expandable cold aisle + multi-factor hybrid access control |
7.2 Compatibility with Different Computer Room Types
| Room Type | Matching Solution | Core Merits |
|---|---|---|
| New-build Data Center | Full hot&cold aisle containment + intelligent access | Optimized airflow at design phase to lower PUE down to 1.25 |
| Legacy Room Retrofit | Single/Double-row cold aisle + access control | Minimal civil renovation with fast cooling efficiency upgrade |
| High-density Computer Room | Sealed cold aisle + precision environmental control | Supports cabinet power over 8kW per rack |
| Modular Prefab DC | Standard modular cold aisle + integrated access | Seamless docking with prefabricated cabinet for fast installation |
| Containerized DC | Custom compact cold aisle + dedicated access | Space-saving with anti-vibration structure |
VIII. Product Competitive Advantages
8.1 Technical Superiority
- Modular fabrication: Pre-produced components for on-site quick assembly cutting construction cycle by over 50%
- Ultra-tight sealing: EPDM + auto-lifting bottom seal with ≤2mm gap; cold leakage<5% vs traditional>15%
- Deep system linkage: Native integration with fire, air conditioning and lighting systems for automatic abnormal response
- Wide compatibility: Fits standard 600/800mm-wide racks with adjustable aisle width 1200~1800mm
- Cloud-enabled remote control: TCP/IP-based Web & mobile terminal real-time monitoring
8.2 Performance Superiority
- Outstanding energy saving: PUE reduced by 0.3~0.5 to deliver 20~30% annual power cut
- Comprehensive safety: Auto emergency release via fire linkage plus dedicated escape hardware
- Stable indoor climate: Aisle temp fluctuation ≤±1℃ with RH maintained between 45~60%
- Granular access governance: Multi-tier authorization & storage of over 100,000 access logs
- Low lifecycle maintenance: ≥15-year component service life with infrequent routine servicing
8.3 Commercial Superiority
- All-in-one turnkey package: Aisle sealing + access + environment monitoring + intelligent linkage under single procurement
- Flexible customization: Custom dimension, function and appearance per client requirements
- Open integration: Seamless docking with mainstream DC management platforms and third-party software
- Full-lifecycle service: In-house design, installation and after-sales maintenance support
- Brand certification: KITOZER specializes in data center infrastructure with multiple international product certifications
IX. Tender Specification Parameters
9.1 Core Technical Bid Specifications
Aisle Containment
- Frame: ≥2.0mm anodized aluminum alloy
- End door:5mm tempered glass with ≥90% transmittance
- Seal: Clearance ≤2mm & cold leakage<5%
- Fire skylight: Fire retardant, 72℃ fusible trigger with fire linkage Supporting third-party test report required
Access Control
- TCP/IP controller storing ≥20,000 cards & ≥100,000 logs
- Default IC/ID+password; optional fingerprint/facial recognition
- Standard TCP/IP for remote management
- DC12V power with overvoltage/overcurrent protection
- Adjustable unlock delay 1~600s Product certification documents required
Environmental Monitoring
- Temp: -10~+60℃ ±0.5℃; Hum:0~100%RH ±3%RH
- Pressure:-50~+50Pa ±1Pa
- 7-inch touch display for real-time parameter view Calibration certification required
Intelligent Linkage
- Fire signal input to auto-open doors/skylights
- AC linkage for load-based cooling adjustment
- Motion-triggered lighting auto on/off delay System compatibility certificate required
Overall Standard
- Aisle width range:1200~1800mm; End door height:2050mm
- Design lifespan≥15 years; Frame IP40 / electronic equipment IP30 Formal quality warranty commitment required
9.2 Commercial Bid Terms
- Bidder holds valid data center infrastructure design & construction qualification
- Minimum 3 completed reference projects with single contract ≥500,000 CNY
- Products certified ISO9001 & ISO14001
- Minimum 5-year product warranty with 24-hour aftersales on-call support
- Custom design service including professional layout proposal & field installation guidance

X. Customized Project Solutions
10.1 New-build Data Center Solution
Overview
Full hot&cold aisle containment plus integrated smart access control optimized in early design phase to realize green DC standard with PUE≤1.3
Core Configuration
- Full enclosed double-row cold aisle (aluminum frame + tempered glass door + fire skylight)
- Dual-factor facial+card access with multi-level user permission
- High-precision multi-point temperature/humidity/pressure/smoke monitoring
- Full linkage with fire suppression, aircon and room lighting
- Cloud central management with Web & mobile remote access
Implementation Steps
- Pre-design planning based on cabinet layout & IT load
- Modular component customized production
- On-site phased installation:Frame→Door→Skylight→Access hardware→Commissioning
- Platform interconnection with host DC management system
- System acceptance & customer maintenance training
Expected Outcome
- PUE lowered to1.25~1.3 with annual power saving over25%
- Zero security incident via precise access management
- 30% reduction in IT hardware failure from stable ambient condition
- 50% higher maintenance efficiency and lower running cost
10.2 Legacy Computer Room Retrofit Solution
Overview
Minimal-disruption cold aisle + access upgrade for running in-service rooms with limited downtime
Core Configuration
- Single/double-row containment matched with existing cabinet layout
- Card+password economical access system for rapid rollout
- Basic critical parameter environmental monitoring
- Simplified fire linkage compatible with existing fire alarm
Implementation Steps
- On-site airflow & safety audit for original facility
- Minimal-modification retrofitting blueprint design
- Standard plus tailor-made component production
- Zonal phased construction avoiding full-room outage
- Compatibility test & parameter fine-tuning
Expected Outcome
- PUE cut down by0.3~0.4 for 20% annual electricity saving
- ≤3-day single aisle construction & maximum4-hour total downtime
- Standardized personnel access management & upgraded security grade
- Payback period within1.5 years
10.3 High-density High-power Computer Room Solution
Overview
Precision airflow containment & high-security biometric access for racks over8kW per unit
Core Configuration
- Individual cold aisle sealing + targeted precision front-to-rack air supply
- Fingerprint/facial high-grade biometric multi-authorization access
- Multipoint high-accuracy distributed environmental monitoring
- Deep linkage with precision air conditioning & UPS power system
Implementation Steps
- CFD thermal simulation to optimize internal airflow layout
- Customized design per thermal analysis result
- On-site containment + air supply + access hardware deployment
- Dynamic real-time cooling adjustment against fluctuating IT load
- Data-driven intelligent operational optimization
Expected Outcome
- Stable operation supporting rack load exceeding10kW
- Room temp fluctuation controlled ≤±0.5℃ with hot spot elimination
- Grade-A physical security preventing core data leakage
- Auto early warning & intelligent troubleshooting for unmanned O&M
XI. Reference Project Cases
Case1: Top-tier Internet Giant Cloud Data Center
Project Profile
- Scale:10 modular computer rooms with total 2000 racks, total load16MW
- Requirement:PUE≤1.3, strict access governance & intelligent maintenance
- Solution:Full hot&cold containment + facial recognition access + centralized management platform
Project Result
- Original PUE1.8 reduced to1.28 saving 30 million kWh annually
- Zero unauthorized access & safety incidents
- 35% reduction of server failure rate under stable environment
- 60% improved maintenance efficiency &40% cut of admin cost
Client Feedback: KITOZER cold aisle access solution helps us hit green data center target while upgrading physical security with ROI beyond expectation.
Case2: Banking Disaster Recovery Center Retrofit
Project Profile
- Scale:2 computer rooms with 300 racks, total load2.4MW
- Requirement:Low downtime renovation, PUE optimization & security upgrade
- Solution:Double-row cold aisle + multi-factor access + environmental monitoring
Project Result
- Full project finished within15 days with cumulative downtime ≤8 hours
- PUE improved from1.7 to1.35 saving5 million kWh per year
- Security elevated to Grade-A compliant with financial industry standard
- 1.2-year investment payback cycle
Client Feedback: Smooth renovation without business interruption; KITOZER solution delivers remarkable energy saving & safety improvement and is highly recommended.
Case3: Government Cloud Computing Center
Project Profile
- Scale:5 modular rooms with 800 racks, total load6.4MW
- Requirement:Modular expandability & remote centralized management
- Solution:Standard modular cold aisle + intelligent access + cloud management platform
Project Result
- 40% shorter construction period via modular prefabrication
- Steady PUE at1.3 meeting official green DC specification
- 50% reduction of on-site maintenance manpower via remote control
- Flexible on-demand expansion to accommodate future business growth
Client Feedback: KITOZER modular cold aisle system enables us to build an efficient, secure and smart government cloud infrastructure with stable reliable performance.
XII. SEO Keywords & Tags
12.1 Core Primary Keywords
- Modular Hot & Cold Aisle Containment System
- Cold Aisle Access Control System
- Data Center Airflow Management Solution
- KITOZER Cold Aisle Containment
- Cold Aisle Enclosure System
- Data Center PUE Optimization
- Computer Room Security Access Control
- Modular Data Center Solution
- Cold Aisle Retrofit Project
- High-density Rack Airflow Management
12.2 Long-tail SEO Keywords
- Cold aisle access control system manufacturer
- Data center hot cold aisle project cost
- Cold aisle containment design specification
- Computer room access control solution
- Modular cold aisle technical features
- Data center energy efficiency upgrade solution
- Cold aisle on-site installation guide
- Fire linkage for access control system
- Data center environmental monitoring system
- Cold aisle brand comparison & selection guide
12.3 Tags
#ModularHotColdAisle #ColdAisleAccess #DataCenter #PUEOptimization #RoomSecurity #AirflowManagement #SmartAccess #EnvMonitoring #GreenDataCenter #KITOZER
XIII. Summary
Combining advanced airflow optimization technology and intelligent access control, KITOZER Modular Hot & Cold Aisle Containment (Cold Aisle Access Control) System delivers an all-in-one efficient, secure and intelligent solution for modern data centers. It drastically optimizes PUE & energy efficiency while reinforcing physical room security and simplifying daily O&M, making it the preferred option for new construction and renovation of global data center facilities.