Table of Contents
Toggle1. System Introduction
The modular hot and cold aisle system is the core airflow management solution for data center computer rooms. It completely separates cold air zones (cold aisles) and hot air zones (hot aisles) via physical isolation technology to realize precise airflow control and high-efficiency cooling.
Adopting the design concept of factory prefabrication and on-site rapid assembly, the KITOZER modular hot & cold aisle system thoroughly solves common problems of traditional computer rooms, such as low cooling efficiency and frequent local hotspots caused by mixing of hot and cold airflow. It effectively reduces the PUE of data centers, and improves space utilization and equipment operation reliability.
This system is applicable to new-built, expanded and renovated data centers. It supports single-row, double-row, multi-row and other deployment modes, and is compatible with mainstream server cabinets and cooling equipment in the market. We provide full lifecycle services including design, production, installation and operation & maintenance for customers.

2. System Composition
The KITOZER modular hot & cold aisle system consists of the following core components:
| Component Category | Specific Composition | Function Description |
|---|---|---|
| Basic Frame System | Aluminum alloy / cold rolled steel uprights, cross beams, connectors | Provide structural support and stability; load capacity ≥ 800kg |
| Aisle Enclosure System | Tempered glass end doors, sliding doors, aisle top panels, blanking panels | Physically isolate hot and cold airflow and prevent air mixing |
| Intelligent Control System | Temperature & humidity sensors, door magnetic switches, controllers, linkage modules | Real-time monitoring of environmental parameters in aisles, linkage with fire fighting system |
| Auxiliary System | LED lighting, fire pressure relief devices, cable troughs | Provide lighting, safety protection and cable arrangement |
| Airflow Optimization Components | Deflectors, air dampers, static pressure boxes | Optimize airflow organization and improve cold air utilization rate |
| Cabinet Matching Parts | Mesh door cabinets, blanking panels, cable troughs | Cooperate with the aisle system to form a complete airflow circulation |
3. System Classification
3.1 Classification by Airflow Organization
| Type | Features | Application Scenarios |
|---|---|---|
| Cold Aisle Containment | Cabinets are arranged face to face with enclosed aisles; cold air enters devices from the aisle | Mainstream application for most data centers; PUE ≤ 1.5 |
| Hot Aisle Containment | Cabinets are arranged back to back with enclosed aisles; hot air is discharged centrally | Suitable for computer rooms with high heat density, compatible with upflow air conditioners |
| Dual Hot & Cold Aisle Containment | Both cold and hot aisles are fully enclosed for complete airflow isolation | For ultra-high density computer rooms (single cabinet power ≥ 10kW); PUE ≤ 1.3 |
3.2 Classification by Deployment Scale
| Type | Specification | Application Scenarios |
|---|---|---|
| Single-row Aisle | Single row of cabinets with single-side enclosure | Small & medium-sized computer rooms, edge computing nodes, rapid deployment |
| Double-row Aisle | Two rows of cabinets arranged oppositely to form a closed aisle in the middle | Medium & large-sized data centers with high space utilization |
| Multi-row Combined Aisle | Multiple rows of cabinets combined to form several closed aisles | Large-scale data centers supporting partition management |
3.3 Classification by Door Type
| Type | Features | Application Scenarios |
|---|---|---|
| Manual Door | Tempered glass manual door with low cost | Small computer rooms with low daily maintenance frequency |
| Automatic Door | Inductive sliding / translating door, support card / password / fingerprint access | Medium & large-sized computer rooms with frequent maintenance to boost efficiency |
| Rapid Rolling Door | Fast opening & closing with good sealing performance | Computer rooms requiring high cleanliness and frequent access |
3.4 Classification by Top Panel Structure
| Type | Features | Application Scenarios |
|---|---|---|
| Fixed Top Panel | Integral / sectional fixed panel with stable structure | Standard computer rooms without frequent top equipment maintenance |
| Movable Top Panel | Openable design for easy maintenance | Computer rooms with pipes and cable troughs on the ceiling |
| Intelligent Adjustable Top Panel | Equipped with electric air dampers to adjust airflow | Computer rooms with dynamic load changes for intelligent cold air distribution |

4. System Configuration List (Brand: KITOZER)
4.1 Standard Configuration of Single-row Cold Aisle Containment System
| No. | Product Name | Model | Quantity | Specification & Parameters |
|---|---|---|---|---|
| 1 | Cold Aisle Frame | KITOZER-LC-01 | 1 Set | Aluminum alloy, height 2400mm, width 1200mm, depth customized according to cabinet quantity |
| 2 | Tempered Glass End Door | KITOZER-LD-02 | 2 Pcs | 12mm tempered glass with stainless steel hinges, size 1200×2400mm |
| 3 | Aisle Top Panel | KITOZER-LT-03 | Customized by length | Cold rolled steel plate, thickness 1.5mm, electrostatic spraying surface |
| 4 | Blanking Panel | KITOZER-LB-04 | Customized by cabinet quantity | 19-inch standard, thickness 1.2mm, compatible with 42U cabinets |
| 5 | Temperature & Humidity Sensor | KITOZER-TS-05 | 2 Pcs | Measuring range: -10℃ ~ +50℃, 0 ~ 100%RH; accuracy ±0.5℃ / ±3%RH |
| 6 | Door Magnetic Switch | KITOZER-MS-06 | 2 Pcs | Monitor door status; contact capacity 10A/250VAC |
| 7 | Intelligent Controller | KITOZER-IC-07 | 1 Pc | Support RS485 communication and Modbus protocol, connectable to DCIM system |
| 8 | LED Lighting | KITOZER-LL-08 | Customized by length | Recessed installation, power 12W/m, color temperature 4000K |
| 9 | Fire Linkage Module | KITOZER-FM-09 | 1 Pc | Receive fire signals and control automatic door opening |
| 10 | Connectors & Fittings | KITOZER-AK-10 | 1 Set | Including bolts, nuts, sealing strips, etc. |
4.2 Standard Configuration of Double-row Hot Aisle Containment System
| No. | Product Name | Model | Quantity | Specification & Parameters |
|---|---|---|---|---|
| 1 | Hot Aisle Frame | KITOZER-HC-01 | 1 Set | Cold rolled steel, height 2400mm, width 1200mm, depth customized according to cabinet quantity |
| 2 | Sliding End Door | KITOZER-HD-02 | 2 Pcs | Tempered glass with aluminum alloy frame, automatic induction, size 1200×2400mm |
| 3 | Movable Top Panel | KITOZER-HT-03 | Customized by length | Openable design, single section length 1500mm with hydraulic support |
| 4 | Deflector | KITOZER-HG-04 | Customized by cabinet quantity | Optimize hot air return path and improve heat dissipation efficiency |
| 5 | Temperature & Humidity Sensor | KITOZER-TS-05 | 4 Pcs | Measuring range: -10℃ ~ +50℃, 0 ~ 100%RH |
| 6 | Differential Pressure Sensor | KITOZER-PS-06 | 2 Pcs | Measure internal and external pressure difference of aisle; range ±500Pa, accuracy ±2%FS |
| 7 | Intelligent Controller | KITOZER-IC-07 | 1 Pc | Support remote monitoring & control, linkage with air conditioning system |
| 8 | Electric Air Damper | KITOZER-EV-08 | 4 Pcs | Adjust hot air exhaust volume, caliber 300×300mm |
| 9 | Fire Pressure Relief Device | KITOZER-FD-09 | 2 Pcs | Automatically open at 68℃, pressure relief area ≥ 0.5㎡ |
| 10 | Cable Trough | KITOZER-CM-10 | Customized by length | Aluminum alloy, width 100mm, height 50mm |
4.3 Custom Configuration of Dual Hot & Cold Aisle Containment System
| No. | Product Name | Model | Quantity | Specification & Parameters |
|---|---|---|---|---|
| 1 | Dual Containment Frame | KITOZER-DC-01 | 1 Set | Composite material, height 2600mm, width 1200mm |
| 2 | Automatic Translating Door | KITOZER-DD-02 | 4 Pcs | Tempered glass with stainless steel frame, induction distance ≥ 1.5m |
| 3 | Intelligent Adjustable Top Panel | KITOZER-DT-03 | Customized by length | Integrated with electric air dampers and temperature & humidity sensors |
| 4 | Deflector & Static Pressure Box | KITOZER-DS-04 | Customized by cabinet quantity | Optimize airflow distribution and reduce wind noise |
| 5 | Multi-parameter Sensor | KITOZER-MS-05 | 4 Pcs | Monitor temperature, humidity, differential pressure and air quality simultaneously |
| 6 | Intelligent Gateway | KITOZER-IG-06 | 1 Pc | Support 5G/4G/Wi-Fi communication and edge computing |
| 7 | Emergency Lighting | KITOZER-EL-07 | 2 Pcs | Built-in battery, emergency power supply duration ≥ 90 minutes |
| 8 | Airflow Visualization System | KITOZER-AV-08 | 1 Set | Real-time display of airflow velocity and temperature distribution in aisles |
| 9 | Access Control System | KITOZER-AM-09 | 1 Set | Support card, password, fingerprint and face recognition |
| 10 | Professional Installation Tools | KITOZER-IT-10 | 1 Set | Including torque wrench, level gauge, distance meter, etc. |

5. System Airflow Schematic
5.1 Airflow Principle of Cold Aisle Containment System
Airflow Path:
- In-row / inter-row / underfloor precision air conditioners deliver cold air into the cold aisle.
- Cold air enters server devices through cabinet mesh doors.
- Heated hot air is exhausted from cabinet rear doors to the hot aisle.
- Hot air rises to the ceiling and is sucked back by air conditioner return air outlets.
- Air conditioners cool down hot air and re-deliver it to the cold aisle to form a circulation.
Description:
- The cold aisle maintains positive pressure relative to the hot aisle to prevent hot air infiltration.
- The hot aisle maintains negative pressure to accelerate hot air exhaust.
- Blanking panels fill vacant cabinet spaces to avoid airflow short circuit.
- Deflectors optimize airflow direction and reduce eddy current and resistance.
5.2 Airflow Principle of Hot Aisle Containment System
Airflow Path:
- Air conditioners deliver cold air to the computer room space.
- Cold air enters server devices through cabinet mesh doors.
- Heated hot air is exhausted from cabinet rear doors to the enclosed hot aisle.
- Hot air is drawn into air conditioner return outlets via exhaust vents on top of the hot aisle.
- Air conditioners cool down hot air and re-deliver it to the computer room to form a circulation.
Description:
- The hot aisle maintains negative pressure to prevent hot air from spreading to other areas.
- The cold aisle (computer room space) maintains positive pressure to push cold air into devices.
- Deflectors guide hot air upward to improve exhaust efficiency.
- Perfectly compatible with upflow air conditioning systems for high heat density scenarios.
5.3 Principle of Intelligent Control System
Control Process:
- Sensors collect real-time data including temperature, humidity, differential pressure and door status.
- Data is transmitted to the intelligent controller for analysis and processing.
- The controller issues control commands according to preset strategies.
- Actuators (air dampers, lighting, doors) respond to adjust status.
- The controller uploads data to the DCIM system via communication modules.
- The DCIM system realizes remote monitoring, data analysis and report generation.
Description:
- Support dual control modes: local control and remote control.
- Equipped with automatic fault detection and alarm functions.
- Linkage with fire fighting system: doors open automatically in case of fire.
- Linkage with air conditioning system: adjust cooling capacity according to aisle temperature.

6. Product Technical Parameters
6.1 Structural Parameters
| Parameter Item | Cold Aisle Containment | Hot Aisle Containment | Dual Hot & Cold Aisle Containment |
|---|---|---|---|
| Material | Aluminum alloy / Cold rolled steel | Cold rolled steel / Stainless steel | Composite (Aluminum alloy + Cold rolled steel) |
| Thickness | Frame: 1.5-2.0mm, Panel: 1.2-1.5mm | Frame: 2.0-2.5mm, Panel: 1.5mm | Frame: 2.0-3.0mm, Panel: 1.5-2.0mm |
| Surface Treatment | Electrostatic spraying, optional colors | Electrostatic spraying / Galvanizing, anti-corrosion | Electrostatic spraying / Original stainless steel finish |
| Load Capacity | ≥ 800kg | ≥ 1000kg | ≥ 1200kg |
| Sealing Performance | Gap ≤ 0.5mm, air leakage rate ≤ 2% | Gap ≤ 0.5mm, air leakage rate ≤ 2% | Gap ≤ 0.3mm, air leakage rate ≤ 1% |
| Door Opening Mode | Manual / Automatic / Sliding | Manual / Automatic / Rolling | Automatic translating / Sliding |
| Door Service Life | ≥ 50,000 times | ≥ 50,000 times | ≥ 100,000 times |
| Aisle Width | 800-1200mm | 800-1200mm | 1000-1400mm |
| Aisle Height | 2200-2600mm | 2200-2600mm | 2400-2800mm |
| Compatible Cabinet | 42U / 47U standard cabinet | 42U / 47U standard cabinet | 42U / 47U standard cabinet |
6.2 Environmental Parameters
| Parameter Item | Technical Index | Remarks |
|---|---|---|
| Operating Temperature | -10℃ ~ +40℃ | Adapt to most computer room environments |
| Storage Temperature | -20℃ ~ +60℃ | Meet transportation and storage requirements |
| Relative Humidity | 10% ~ 90%RH, non-condensing | Prevent condensation from affecting equipment |
| Ingress Protection | IP20 | Prevent human contact with live parts |
| Vibration Resistance | 5-15Hz, amplitude ≤ 0.1mm | Resist vibration generated by computer room equipment |
| Noise Level | ≤ 55dB | Comply with computer room noise standards |
| EMC | Comply with GB/T 17626 | No interference to other on-site equipment |
| Fire Resistance Grade | B1 | Meet computer room fire protection requirements |
| Environmental Standard | Comply with RoHS | Eco-friendly and non-toxic |
6.3 Intelligent Control Parameters
| Parameter Item | Technical Index | Remarks |
|---|---|---|
| Communication Interface | RS485, Ethernet, Wi-Fi | Multiple communication options |
| Communication Protocol | Modbus RTU/TCP, SNMP | Compatible with mainstream DCIM systems |
| Data Acquisition Interval | Adjustable from 1s to 60s | Meet different monitoring demands |
| Control Accuracy | Temperature ±0.5℃, Humidity ±3%RH | Precise environmental control |
| Alarm Mode | Local audible & visual alarm, remote SMS / Email alarm | Timely fault notification |
| Linkage Function | Support linkage with fire fighting, air conditioning and access control systems | Collaborative operation between systems |
| Power-off Protection | Built-in backup battery, duration ≥ 30 minutes | Ensure data integrity during power failure |
| Historical Data Storage | ≥ 365 days | Support data analysis and trend prediction |
| User Management | Multi-level authority management | Guarantee system security |

7. Application Scope
7.1 Data Center Types
| Data Center Type | Application Situation | Recommended Solution |
|---|---|---|
| Large Cloud Data Center | High-density deployment, large-scale cluster, strict PUE requirements | Dual hot & cold aisle containment + intelligent control system |
| Small & Medium-sized Enterprise Data Center | Medium density, rapid deployment, cost-sensitive | Cold aisle containment with manual doors and fixed top panels |
| Edge Computing Node | Small capacity, distributed deployment, remote management | Single-row cold aisle containment + intelligent controller |
| Financial Data Center | High reliability, 24×7 operation, strict compliance | Dual hot & cold aisle containment with redundant configuration |
| Government Data Center | High security and stability requirements | Cold aisle containment + access control & fire linkage |
| Internet Enterprise Data Center | Fast iteration, flexible expansion, high heat density | Hot aisle containment with expandable frame |
| Medical Data Center | High cleanliness requirement, continuous operation | Cold aisle containment with automatic doors and air filtration |
| Education & Research Data Center | Experimental environment, diversified demands | Custom hot & cold aisle system with flexible configuration |
7.2 Computer Room Renovation Scenarios
| Renovation Scenario | Pain Points | Solution |
|---|---|---|
| Local hotspots in traditional computer rooms | Hot and cold airflow mixing, low cooling efficiency | Cold aisle containment to eliminate local hotspots |
| Computer room expansion | Insufficient cooling capacity caused by new equipment | Hot aisle containment to improve cooling efficiency |
| PUE optimization | PUE > 1.8, high energy cost | Dual hot & cold aisle containment, PUE reduced below 1.3 |
| Space utilization improvement | Space shortage and low deployment density | Modular hot & cold aisle system, space utilization over 80% |
| O&M efficiency improvement | Narrow maintenance passages and inconvenient operation | Automatic doors + movable top panels for easier maintenance |
| Fire compliance renovation | Failure to meet latest fire codes | Fire linkage modules + pressure relief devices |

8. Product Advantages
8.1 High Efficiency & Energy Saving, Lower PUE
- Complete isolation of hot and cold airflow eliminates airflow short circuit; cold air utilization rate exceeds 90%. PUE drops to 1.3~1.5 (traditional computer room PUE > 1.8).
- On-demand cooling: the intelligent system adjusts cooling capacity in real time according to aisle temperature to avoid energy waste from over-cooling.
- Reduce air conditioner operating time by over 30% and cut energy costs significantly.
8.2 Improve Equipment Reliability & Service Life
- Eliminate local hotspots and keep equipment operating within the optimal temperature range (22-24℃) to reduce equipment failures.
- Stabilize operating environment and temperature fluctuation, extending equipment service life by over 15%.
- Closed design reduces dust ingress and lowers failure rate.
8.3 Rapid Deployment & Shorter Construction Cycle
- Factory prefabrication of all components; only on-site assembly is needed, cutting deployment time by over 50%.
- Modular and standardized components with good interchangeability, supporting rapid expansion and adjustment.
- High system integration enables seamless connection with cabinets and air conditioners for simple installation.
8.4 Flexible Expansion for Various Scenarios
- Support single-row, double-row, multi-row and other deployment modes to adapt to different room layouts.
- Compatible with more than 99% of mainstream server cabinets and cooling equipment on the market, no need to replace existing devices.
- Customized solutions are available to meet special requirements.
8.5 Intelligent Management & Higher O&M Efficiency
- Multi-parameter sensors collect environmental data in real time for early anomaly detection.
- Remote monitoring and control via DCIM system reduces on-site workload.
- Intelligent data analysis realizes fault early warning and improves system reliability.
- Detailed statistics on energy consumption and environmental parameters support computer room optimization.
8.6 Safety & Compliance
- High-strength materials and solid structure ensure stable system operation.
- Seamless linkage with fire fighting system; doors open within seconds in case of fire to guarantee personnel safety.
- Comply with national standard GB 50174-2017 Code for Design of Data Centers.
- All components pass strict tests; design service life ≥ 10 years with comprehensive after-sales service.

9. Bid Specification Parameters
9.1 General Parameters
- The system shall comply with GB 50174-2017, with construction standard no lower than Grade B.
- Adopt modular design; all components shall be prefabricated and fully tested in factory; on-site deployment period ≤ 7 days.
- PUE ≤ 1.5 for cold aisle containment system; PUE ≤ 1.3 for dual hot & cold aisle containment system.
- Cold air utilization rate ≥ 90% after enclosure; temperature uniformity in aisle ≤ ±1℃ with no local hotspots.
- Support fire linkage; aisle doors open automatically within 5 seconds after receiving fire signals.
- Equipped with intelligent monitoring function, connectable to DCIM system with complete API interfaces provided.
- Ingress protection grade ≥ IP20, fire resistance grade ≥ B1.
- Design service life ≥ 10 years, MTBF ≥ 50,000 hours.
- Support single-row, double-row and multi-row deployment.
- Compatible with mainstream server cabinets and cooling equipment without replacement.
9.2 Parameters for Cold Aisle Containment System
- Aisle frame made of aluminum alloy, thickness ≥ 2.0mm, load capacity ≥ 800kg.
- End doors adopt 12mm tempered glass, light transmittance ≥ 90%, complying with GB 15763.2.
- Aisle top panel: cold rolled steel plate with thickness ≥ 1.5mm, electrostatic anti-corrosion coating.
- Blanking panel: 1.2mm cold rolled steel, 19-inch standard, 100% filling rate for vacant cabinet spaces.
- Temperature & humidity sensor accuracy: ±0.5℃ / ±3%RH, support RS485 communication.
- Door magnetic switch contact capacity ≥ 10A/250VAC, response time ≤ 0.1s.
- Intelligent controller supports Modbus protocol and connection to third-party DCIM systems.
- LED lighting power ≤ 12W/m, color temperature 4000K, service life ≥ 50,000 hours.
- System air leakage rate ≤ 2%.
- Door opening service life ≥ 50,000 times.
9.3 Parameters for Intelligent Control System
- Collect temperature, humidity, differential pressure and door status simultaneously; acquisition interval adjustable from 1s to 60s.
- Communication interfaces: RS485, Ethernet, Wi-Fi.
- Dual control modes: local and remote.
- Automatic fault detection with local audible & visual alarm and remote SMS/Email alarm.
- Fire linkage function for automatic door opening.
- Linkage with air conditioning system to adjust cooling capacity.
- Historical data storage duration ≥ 365 days, data export supported.
- Multi-level authority management.
- Built-in backup battery, power-off working duration ≥ 30 minutes.
- Comply with EMC standard GB/T 17626.
10. Solutions
10.1 New-built Data Center Solution
Overview: Provide full lifecycle modular hot & cold aisle solutions including design, production, installation and O&M. Combine with KITOZER intelligent cabinets and precision air conditioners to build an efficient, intelligent and green data center.
Core Advantages:
- Factory prefabrication and rapid on-site assembly, construction cycle reduced by over 50%.
- Complete airflow isolation, PUE controlled at 1.3~1.5 to cut energy cost greatly.
- Support high-density deployment (single cabinet power ≥ 10kW), space utilization over 80%.
- Remote intelligent management reduces O&M cost by over 30%.
Implementation Steps:
- Demand analysis
- Customized solution design
- Factory production and testing
- Professional on-site installation
- Joint commissioning with cabinets, air conditioners and DCIM
- Operation & maintenance training
- 7×24 after-sales technical support
10.2 Traditional Computer Room Renovation Solution
Overview: Solve problems of airflow mixing, low cooling efficiency and local hotspots for legacy computer rooms. No large-scale modification on existing equipment.
Core Advantages:
- No need to replace existing cabinets and air conditioners, low renovation cost and high ROI.
- Rapid construction without interrupting normal operation.
- Eliminate hotspots, improve equipment reliability and extend service life.
- PUE reduced from above 1.8 to below 1.5 with remarkable energy-saving effect.
Implementation Steps:
- Current situation assessment
- Targeted renovation design
- Component production
- On-site reconstruction without service interruption
- System commissioning
- Effect evaluation
- Continuous optimization
10.3 High-density Data Center Solution
Overview: Adopt dual hot & cold aisle containment for computer rooms with single cabinet power ≥ 10kW. Cooperate with in-row air conditioners and intelligent control system for precise airflow management.
Core Advantages:
- Dual full containment, PUE reduced below 1.3.
- Near-end cooling matched with in-row air conditioners, cooling efficiency increased by over 30%.
- Real-time monitoring of temperature and differential pressure for dynamic airflow adjustment.
- Meet demands of large cloud data centers and supercomputing centers.
10.4 Edge Computing Node Solution
Overview: Miniaturized and intelligent modular hot & cold aisle solution for distributed edge nodes, supporting rapid deployment and remote management.
Core Advantages:
- Compact design adapting to limited space of edge nodes.
- On-site installation within 1 day for fast launch.
- Intelligent remote monitoring reduces on-site O&M work.
- PUE below 1.5 to meet energy consumption requirements of edge sites.
11. Application Cases
11.1 Case 1: Cloud Data Center of Large Internet Enterprise
Background: New large cloud data center with 1000 cabinets, single cabinet power 8kW, PUE ≤ 1.4 required and tight construction schedule.
Solution: Double-row dual hot & cold aisle containment system matched with in-row precision air conditioners and intelligent control system.
Effect:
- PUE dropped to 1.32, annual electricity saving about 2 million RMB.
- Space utilization reached 85%, 200 more cabinets deployed within the same area.
- Construction cycle shortened to 3 months, 2 months faster than traditional schemes.
- Local hotspots eliminated, equipment failure rate reduced by 40%.
- Remote management cut on-site O&M staff by 30%.
11.2 Case 2: Data Center Renovation for Financial Institution
Background: Legacy data center with PUE up to 1.8, severe local hotspots and high equipment failure rate. Energy-saving renovation required with zero service interruption.
Solution: Cold aisle containment system applied on original rooms, compatible with existing air conditioners and cabinets.
Effect:
- PUE reduced to 1.48, annual electricity saving about 800,000 RMB.
- Equipment operating temperature stabilized at 22-24℃.
- Total renovation period only 15 days.
- Equipment failure rate reduced by 35%, service life extended.
- ROI up to 200%, investment recovered within 1 year.
11.3 Case 3: Edge Computing Nodes for Government Agency
Background: 20 distributed edge computing nodes across the city, 10 cabinets for each node, requiring rapid deployment and remote management.
Solution: Single-row cold aisle containment system with small precision air conditioners and intelligent controllers.
Effect:
- Each node installed within 1 day; all 20 nodes completed within 1 month.
- PUE 1.45, meeting green data center standards.
- Fully remote management without on-site duty staff.
- System failure rate ≤ 0.5%.
- O&M cost reduced by 50%.
11.4 Case 4: Medical Industry Data Center
Background: New data center for medical image data storage and processing, requiring high reliability, high cleanliness and low noise.
Solution: Cold aisle containment system equipped with automatic doors, air filtration and low-noise air conditioners.
Effect:
- PUE 1.42, meeting green hospital standards.
- Automatic doors and filtration improve room cleanliness.
- Noise controlled at 52dB for a quiet working environment.
- Stable operation all year round to ensure medical data security.
- Remote monitoring lowers O&M cost.
12. Keywords, SEO & Tags
12.1 Core Search Keywords
Modular hot and cold aisle, KITOZER hot and cold aisle, cold aisle containment system, hot aisle containment system, data center airflow management, computer room hot & cold aisle solution, modular computer room, data center PUE optimization, local hotspot solution for computer room, bid parameters for modular hot & cold aisle
12.2 SEO Keywords
Introduction to modular hot & cold aisle system, composition of modular hot & cold aisle system, classification of modular hot & cold aisle system, schematic diagram of modular hot & cold aisle system, technical parameters of modular hot & cold aisle products, application scope of modular hot & cold aisle products, advantages of modular hot & cold aisle products, bid parameters of modular hot & cold aisle products, solutions of modular hot & cold aisle products, application cases of modular hot & cold aisle products
12.3 Tags
#ModularHotColdAisle #KITOZER #ColdAisleContainment #HotAisleContainment #DataCenter #ComputerRoom #AirflowManagement #PUEOptimization #EnergySaving #IntelligentControl #GreenDataCenter #ComputerRoomRenovation #HighDensityDeployment #EdgeComputing #FinancialDataCenter #MedicalDataCenter