KITOZER Modular Single-Row Cold Aisle Containment System Solution

I. System Introduction

The KITOZER Modular Single-Row Cold Aisle Containment System is a high-efficiency airflow management solution specially designed for small and medium-sized data centers and computer rooms. Adopting a linear single-row cabinet layout, it forms an independent cold air zone through enclosed cold aisle containment. Cooperated with in-row precision air conditioners for proximal cooling, it completely isolates cold and hot airflow, eliminates local hotspots, significantly improves cooling efficiency, and reduces the PUE value to the range of 1.3-1.5. Featuring a modular design concept, the system supports rapid deployment (installation completed within several hours) and flexible expansion, making it ideal for space-limited scenarios with 6-12 cabinets, such as government and enterprise branch computer rooms, primary and secondary school campus computer rooms, hospital outpatient computer rooms, and medium-sized enterprise headquarters IT computer rooms.

Core Working Principle

Cold air is delivered to the enclosed cold aisle via in-row precision air conditioners or raised floors. The cold air enters IT equipment through cabinet mesh doors and absorbs heat, then the heated hot air is exhausted from the rear of cabinets to the open hot aisle, and finally recycled and processed by the air conditioner return air outlet to form a precise airflow circulation. The cold air utilization rate is increased to over 90%.

II. System Composition

System ModuleCore ComponentsFunction Description
Cold Aisle Containment SystemAisle end doors (sliding/ double doors), aisle top plates, sealing rubber strips, partition columnsForm a fully physical enclosed space to prevent cold and hot air mixing, with cold air leakage rate <5%
Cabinet SystemStandard server cabinets, mesh doors, blanking panels, cable organizersProvide installation space for IT equipment, optimize airflow paths and eliminate airflow short circuits
Cooling SystemIn-row precision air conditioners, temperature sensors, airflow distributorsRealize proximal cooling, precisely control cold aisle temperature at 18-22℃ with temperature difference ≤±1℃
Power Supply & Distribution SystemPrecision distribution cabinets, UPS modules, PDU, battery packsProvide stable and reliable power supply, support N+1 redundant configuration to ensure continuous system operation
Monitoring & Management SystemTemperature and humidity sensors, smoke detectors, access control system, intelligent management platformReal-time monitoring of aisle environment, automatic alarm for abnormalities, and support remote monitoring and management
Auxiliary SystemEmergency lighting, fire linkage devices, ventilation systemGuarantee personnel safety, comply with computer room fire protection specifications, and automatically activate ventilation in emergencies
(single row cold aisle) system solution (1)

III. System Classification

1. Classification by Sealing Degree

TypeStructural FeaturesApplicable ScenariosEnergy Efficiency Ratio
Fully Enclosed Single-Row Cold AisleFull sealing with end doors, top plates and side plates for complete cold and hot air isolationHigh-density cabinets (single cabinet power density ≤5kW) with high cooling efficiency requirements★★★★★
Semi-Enclosed Single-Row Cold AisleEnd doors and top plates sealed, side plates openMedium and low-density cabinets, balancing heat dissipation and maintenance convenience★★★★☆
Simplified Enclosed Single-Row Cold AisleOnly end doors sealed, top plates optionalScenarios with limited budget and general cooling efficiency requirements★★★☆☆

2. Classification by Cooling Mode

TypeCooling EquipmentAdvantagesApplicable Environment
Air-Cooled Single-Row Cold AisleAir-cooled in-row air conditionerSimple installation, no water pipe required, suitable for waterless computer roomsOrdinary computer rooms without centralized water cooling system
Water-Cooled Single-Row Cold AisleWater-cooled in-row air conditioner + CDUHigh cooling efficiency, lower PUE (1.2-1.3)High-density computer rooms with centralized water cooling system
Free-Cooling Fluorine Pump TypeFluorine pump in-row air conditionerUtilize natural cold sources, energy saving rate over 30%Cool climate areas with low annual average temperature

3. Classification by Scale

ScaleNumber of CabinetsLoad PowerAisle LengthApplicable Scenarios
Small-Scale Single-Row Cold Aisle3-6 units10-25kW3-6mSmall enterprises, branch computer rooms
Medium-Scale Single-Row Cold Aisle6-12 units25-50kW6-12mMedium-sized enterprises, government departments, hospitals
Large-Scale Single-Row Cold Aisle12-24 units50-100kW12-24mLarge enterprises, data center edge nodes

IV. Standard System Configuration List (Brand: KITOZER)

No.Product NameModelBrandQuantityTechnical Specifications
I. Cold Aisle Containment Components
1Aisle End DoorKT-CD-1200KITOZER2 Sets1200mm width, frameless explosion-proof tempered glass, aluminum alloy frame, sliding design with door lock
2Aisle Top PlateKT-CT-1200KITOZERBy Meter1200mm width, composite metal material, light transmittance 85%, Class A fire rating, load capacity ≥100kg/㎡
3Sealing Rubber StripKT-CS-01KITOZERCustom QuantityHigh temperature resistance (-30℃~80℃), waterproof, anti-aging, excellent sealing performance
4Partition ColumnKT-CP-2000KITOZERCustom Quantity2000mm height, 1.5mm cold-rolled steel plate, electrostatic spraying surface, seamless connection with cabinets
II. Cabinet System
5Standard Server CabinetKT-RACK-600KITOZER6-12 Units2000×600×1100mm, seven-fold profile main frame, 2.0mm SPCC steel plate, mesh door opening rate ≥75%
6Blanking PanelKT-BP-01KITOZERCustom QuantityCabinet-matched, 1.0mm cold-rolled steel plate, for sealing unused U positions
7Cable OrganizerKT-WM-01KITOZER1 Pcs Per Cabinet19-inch standard installation, metal material, supporting horizontal and vertical cable management
III. Cooling System
8In-Row Precision Air ConditionerKT-CA-20KITOZER1-2 Units20kW cooling capacity, frequency conversion control, precise temperature and humidity control, hot-swappable design
9Temperature SensorKT-TS-01KITOZER2-4 PcsMeasuring range: -10℃~50℃, accuracy ±0.5℃, RS485 communication
IV. Power Supply & Distribution System
10Precision Distribution CabinetKT-PD-630KITOZER1 Set630A input, multiple 16A/32A outputs, remote monitoring support, overload and short circuit protection
11UPS ModuleKT-UPS-20KITOZER1+1 Sets20kW power module, modular hot-swappable design, efficiency ≥95%
12PDUKT-PDU-16KITOZER1 Pcs Per Cabinet16A input, 10-channel 10A output, lightning protection and overload protection
13Battery PackKT-BAT-12KITOZERCustom Quantity12V/100Ah maintenance-free lead-acid battery, supporting 1-8 hours long delay configuration
V. Monitoring & Management System
14Intelligent Management PlatformKT-MP-01KITOZER1 SetWeb access supported, real-time monitoring of temperature, humidity, power parameters and alarm information
15Temperature & Humidity SensorKT-TH-01KITOZER2 PcsTemperature: 0-50℃, Humidity: 20%-90%RH, humidity accuracy ±2%RH
16Smoke DetectorKT-SD-01KITOZER1 PcsPhotoelectric type, sensitivity 0.65-1.5dB/m, fire linkage supported
17Access Control SystemKT-AC-01KITOZER1 SetCard + password verification, remote door opening and record query supported
VI. Auxiliary System
18Emergency LightingKT-EL-01KITOZER2 PcsLED light source, auto start after power failure, continuous lighting ≥90 minutes
19Fire Linkage DeviceKT-FA-01KITOZER1 SetLinked with aisle doors, automatically open end doors to release pressure in case of fire
20Ventilation SystemKT-VS-01KITOZER1 SetForced ventilation in emergencies to ensure personnel safety
(single row cold aisle) system solution (2)

V. System Schematic & Airflow Principle

Airflow Flow Chart

In-row Air Conditioner → Enclosed Cold Aisle (Cold Pool) → Cabinet Mesh Door → IT Equipment Heat Absorption → Cabinet Rear Door → Open Hot Aisle → Air Conditioner Return Air Inlet → Cooling & Recirculation

Airflow Operation Description

1. The in-row air conditioner delivers cold air to the enclosed cold aisle to form an independent cold pool with stable cold air concentration.

2. Cold air uniformly enters IT equipment through cabinet mesh doors to take away operating heat.

3. The heated hot air is discharged from the cabinet rear to the open hot aisle area.

4. Hot air rises naturally and is recovered by the air conditioner return air inlet, then cooled and recycled to the cold aisle.

5. A high-efficiency closed-loop airflow circulation is formed without cold and hot air mixing, increasing cooling efficiency by over 30%.

VI. Core Technical Parameters

1. Cold Aisle Containment System Parameters

Parameter ItemTechnical IndexRemark
Aisle WidthStandard 1200mm, customizable 800-1800mmAdapt to 1-2 anti-static floor widths
Aisle Height2000-2400mmAdapt to standard cabinet height
End Door Material≥8mm frameless explosion-proof tempered glass + aluminum alloy frameLight transmittance ≥90%, high impact resistance
Top Plate MaterialComposite metal plate with anti-static coatingClass A fire rating, load capacity ≥100kg/㎡
Sealing PerformanceCold air leakage rate <5%, excellent air tightnessComply with GB 50174 Data Center Design Specification
Fire RatingOverall Class A fire protectionMeet computer room fire protection requirements
Installation MethodModular splicing, no welding requiredFast installation, detachable and expandable

2. Cabinet System Parameters

Parameter ItemTechnical IndexRemark
Size SpecificationStandard 2000×600×1100mm, customizableOptional 800mm width, 950-1200mm depth
MaterialSeven-fold profile main frame, 2.0mm SPCC cold-rolled steel plateHigh structural strength, load capacity ≥1000kg
Mesh DoorOpening rate ≥75%Optimize airflow path and reduce wind resistance
Protection GradeIP20Dustproof, ensure equipment safety
ColorBlack/Grey (customizable)Electrostatic spraying, anti-corrosion and durable
Cabinet CombinationUnlimited cabinet combination supportedModular combination for variable length requirements

3. Cooling System Parameters

Parameter ItemTechnical IndexRemark
In-row Air Conditioner Cooling Capacity10-30kW (standard), N+1 redundancy supportedAdapt to variable load requirements
Temperature Control Accuracy18-22℃ (adjustable), temperature difference ≤±1℃Comply with ANSI/TIA-942 standard
Humidity Control Accuracy45%-60%RH, fluctuation ≤±3%Prevent equipment condensation and ensure stable operation
Air Supply ModeHorizontal air supply, proximal coolingShort cold air delivery distance and high efficiency
Fan TypeEC variable frequency fanEnergy saving ≥30%, low noise ≤60dB
Communication InterfaceRS485, Modbus protocol supportedAccess to intelligent management platform for remote monitoring

4. Monitoring & Management System Parameters

Parameter ItemTechnical IndexRemark
Monitoring ParametersTemperature, humidity, smoke, access status, air conditioner operating parametersFull coverage of key environmental indicators
Temperature Measuring Range & Accuracy-10℃~50℃, accuracy ±0.5℃Real-time monitoring of cold aisle temperature changes
Humidity Measuring Range & Accuracy20%-90%RH, accuracy ±2%RHPrevent equipment failure caused by abnormal humidity
Alarm ModeSound & light alarm, SMS alarm, email alarmMulti-channel reminder for timely abnormality handling
Management PlatformWeb access supported, Chinese & English bilingual interfaceRemote monitoring, historical data query and report generation
Data StorageHistorical data storage ≥1 yearMeet data analysis and audit requirements
(single row cold aisle) system solution (3)

VII. Application Scope

1. Industry Applications

  • Government Institutions: Regional government cloud computer rooms, sub-district office computer rooms, police station computer rooms
  • Education Industry: Primary and secondary school campus computer rooms, university laboratory computer rooms, vocational college training centers
  • Medical Industry: Hospital outpatient computer rooms, community health service center computer rooms, medical imaging centers
  • Enterprise Users: Medium-sized enterprise headquarters IT computer rooms, branch computer rooms, R&D center test computer rooms
  • Financial Industry: Bank outlet computer rooms, securities business department computer rooms, insurance branch computer rooms
  • Energy Industry: Substation control rooms, new energy enterprise data acquisition computer rooms
  • Internet Industry: Edge computing nodes, small IDC computer rooms, e-commerce enterprise data centers

2. Applicable Scenario Characteristics

  • Number of cabinets: 6-12 units (standard configuration), expandable to 24 units
  • Single cabinet power density: ≤5kW (suitable for ordinary servers and storage devices)
  • Computer room space: Area ≤100㎡, clear height ≥2.8m
  • Deployment cycle: Fast online launch (≤1 week), supporting later capacity expansion
  • Energy efficiency requirement: PUE ≤1.5, compliant with green data center standards
(single row cold aisle) system solution (4)

VIII. Core Product Advantages

1. High Energy Saving & Low PUE

  • Significant PUE reduction: Complete cold and hot air isolation improves cooling efficiency by 30%, reducing PUE to 1.3-1.5 with annual power savings of tens of thousands of yuan
  • Improved cold air utilization: Enclosed design increases cold air utilization rate from traditional 60% to over 90%, reducing cooling equipment configuration demand
  • Intelligent frequency conversion control: EC fans of in-row air conditioners automatically adjust speed according to load to further reduce energy consumption

2. Rapid Deployment & Flexible Expansion

  • Modular design: All components are factory prefabricated, only on-site splicing required, shortening deployment cycle from weeks to hours
  • Plug-and-play: Pre-integrated power supply, cooling and monitoring systems, ready for operation after power-on
  • Seamless expansion: Support on-demand capacity expansion from 3 to 24 cabinets to protect initial investment

3. Precise Temperature Control & High Reliability

  • Zero local hotspots: Enclosed cold aisle + proximal cooling ensures uniform aisle temperature with deviation ≤±1℃, eliminating hotspots (≤24℃)
  • Redundant configuration: Support N+1 cooling and UPS redundancy to ensure continuous system operation with MTBF ≥100,000 hours
  • Intelligent monitoring: Real-time environmental parameter monitoring and automatic abnormality alarm reduce downtime risk by 70% with early fault warning

4. Low Cost & Easy Maintenance

  • Low initial investment: Save over 30% of space and equipment cost compared with double-row cold aisle systems
  • Low operating cost: 30%+ energy saving, 50% reduction in maintenance labor cost, and extended equipment service life
  • Convenient maintenance: Quick-opening aisle end doors, front and rear cabinet maintainability without entering the cold aisle
  • Noise reduction: Enclosed structure effectively reduces equipment operating noise and improves on-site working environment

5. Safety & Compliance

  • Fire safety: All materials adopt Class A fireproof grade, equipped with fire linkage devices, complying with GB 50174-2017 standards
  • Personnel safety: Equipped with emergency lighting and emergency passage design to ensure maintenance personnel safety
  • Environmental compliance: High energy efficiency conforms to national green data center policies and supports enterprise carbon emission reduction goals
(single row cold aisle) system solution (6)

IX. Bid Winning Core Parameters

1. Core Technical Requirements

  • The system shall adopt single-row linear cabinet layout and fully enclosed cold aisle design with cold air leakage rate <5%, complying with GB 50174 Data Center Design Specification
  • Standard cold aisle width is 1200mm, customizable 800-1800mm, adapting to 1-2 anti-static floor widths
  • Cabinets shall adopt seven-fold profile main frame and 2.0mm SPCC cold-rolled steel plate, with mesh door opening rate ≥75% and load capacity ≥1000kg
  • The cooling system adopts in-row precision air conditioners for proximal cooling, with temperature control range 18-22℃ (temperature difference ≤±1℃) and humidity control range 45%-60%RH
  • System PUE ≤1.5, cold air utilization rate ≥90%, energy saving efficiency ≥30% compared with traditional computer rooms
  • The monitoring system shall support real-time monitoring of temperature, humidity, smoke, access and air conditioner parameters, with multi-channel alarm functions (sound & light, SMS, email)

2. Key Component Technical Standards

Component NameBid Winning RequirementsTesting Standard
Cold Aisle End Door≥8mm frameless explosion-proof tempered glass, aluminum alloy frame, light transmittance ≥90%GB 15763.2-2005
Cold Aisle Top PlateComposite metal plate, Class A fire rating, load capacity ≥100kg/㎡GB 8624-2012
Server Cabinet2000×600×1100mm, 2.0mm SPCC cold-rolled steel plate, IP20 protection gradeGB 2887-2011
In-Row Air ConditionerCooling capacity ≥20kW, EC variable frequency fan, noise ≤60dB, Modbus protocol supportedGB/T 19413-2010
UPS ModulePower ≥20kW, modular hot-swappable design, efficiency ≥95%GB/T 14715-2017
Monitoring PlatformWeb access supported, historical data storage ≥1 year, Chinese & English bilingual interfaceGB/T 2887-2011

3. Construction & Acceptance Standards

  • Adopt modular splicing installation without welding, installation cycle ≤3 days for 12-cabinet configuration
  • Complete air tightness test after cold aisle sealing, cold air leakage rate <5% to meet design requirements
  • Conduct temperature field test after stable system operation, no local hotspots (≤24℃) and temperature difference ≤±1℃ in the cold aisle
  • Provide complete test reports including PUE value, cold air utilization rate and temperature uniformity during acceptance
  • Provide ≥3-year warranty, 7×24-hour technical support, fault response time ≤4 hours, problem solving time ≤24 hours

X. Customized Solution Packages

1. Standard 6-Cabinet Solution

Applicable Scenarios: Small enterprise computer rooms, branch computer rooms, campus computer rooms

Core Configuration:

  • Cold aisle containment system: 6m length, 1200mm width, including 2 sets of end doors, 6 top plates, 5 partition columns
  • Cabinet system: 6 sets of standard server cabinets (2000×600×1100mm), equipped with blanking panels and cable organizers
  • Cooling system: 1 set of 20kW in-row precision air conditioner, 2 temperature sensors
  • Power supply & distribution system: 1 precision distribution cabinet, 1+1 sets of 20kW UPS modules, 6 PDUs, 1 battery pack set
  • Monitoring system: 1 set of intelligent management platform, 2 temperature & humidity sensors, 1 smoke detector, 1 access control system
  • Auxiliary system: 2 emergency lights, 1 fire linkage device, 1 ventilation system set

Features: Rapid deployment (≤1 day), PUE ≤1.5, suitable for load ≤25kW scenarios

2. Extended 12-Cabinet Solution

Applicable Scenarios: Medium-sized enterprise computer rooms, government department computer rooms, hospital computer rooms

Core Configuration:

  • Cold aisle containment system: 12m length, 1200mm width, including 2 sets of end doors, 12 top plates, 11 partition columns
  • Cabinet system: 12 sets of standard server cabinets, equipped with blanking panels and cable organizers
  • Cooling system: 2 sets of 20kW in-row precision air conditioners (N+1 redundancy), 4 temperature sensors
  • Power supply & distribution system: 1 precision distribution cabinet, 2+1 sets of 20kW UPS modules, 12 PDUs, 2 battery pack sets
  • Monitoring system: 1 set of intelligent management platform, 4 temperature & humidity sensors, 2 smoke detectors, 1 access control system
  • Auxiliary system: 4 emergency lights, 1 fire linkage device, 1 ventilation system set

Features: High reliability, PUE ≤1.4, suitable for load ≤50kW scenarios, support later expansion to 24 cabinets

3. Customized Special Solutions

  • High-Density Configuration: Support single cabinet power density 5-8kW, equipped with high-efficiency in-row air conditioners and reinforced cold aisle sealing
  • Waterless Computer Room Configuration: Adopt air-cooled in-row air conditioners without water pipes, suitable for anhydrous environments
  • Low-Noise Configuration: Adopt low-noise in-row air conditioners (≤55dB), suitable for computer rooms near office areas
  • Long-Delay Power Supply Configuration: UPS battery pack supports 4-8 hours power delay to ensure continuous operation of key businesses
(single row cold aisle) system solution (8)

XI. Typical Application Cases

Case 1: Campus Computer Room Renovation Project of Municipal Education Bureau

Project Background: The original open-layout computer room suffered from severe local hotspots (32℃) and high energy consumption with PUE up to 2.1.

Solution: Adopt KITOZER 6-cabinet standard single-row cold aisle system, equipped with 20kW in-row air conditioner and 1+1 UPS redundancy configuration.

Implementation Effect:

  • Cold aisle temperature stabilized at 20±1℃ with zero local hotspots
  • PUE reduced to 1.4, annual power saving of about 30,000 CNY
  • Completed deployment within 1 day without affecting teaching operations
  • Intelligent remote monitoring reduces maintenance manpower by 50%

Case 2: New Outpatient Computer Room Project of Grade A Hospital

Project Background: The new outpatient building required a IT computer room with rapid deployment, high reliability and low energy consumption.

Solution: Adopt KITOZER 12-cabinet extended single-row cold aisle system with 2 sets of 20kW N+1 redundant in-row air conditioners.

Implementation Effect:

  • Zero system failure record after 1-year stable operation, ensuring continuous operation of medical systems
  • PUE reaches 1.35, meeting green hospital construction standards
  • Enclosed cold aisle reduces computer room noise and improves working environment
  • Support later expansion to 24 cabinets to meet growing business demands

Case 3: Enterprise Branch Standardized Computer Room Project

Project Background: The enterprise needed to build standardized computer rooms for multiple national branches with rapid delivery and low cost.

Solution: Adopt KITOZER 6-cabinet standard modular single-row cold aisle system with factory prefabricated components.

Implementation Effect:

  • Unified national standard, single-site deployment cycle ≤3 days, construction cost reduced by 30%
  • Centralized remote management reduces on-site IT maintenance staffing
  • All site PUE ≤1.5, achieving group energy saving and emission reduction goals
  • Rapidly respond to business expansion and support on-demand capacity expansion
(single row cold aisle) system solution (9)

XII. SEO Keywords & Tags

Core Search Keywords

Modular cold and hot aisle, single-row cold aisle, data center cold aisle, computer room cold and hot aisle, KITOZER cold aisle, small and medium-sized data center solution, cold aisle containment system, in-row air conditioner cooling, low PUE computer room solution, rapid deployment computer room system

SEO Optimization Description

1. Core keyword density: The core keyword “modular single-row cold aisle containment system” appears more than 10 times throughout the text, and related keywords such as “cold aisle containment system” and “in-row air conditioner” appear more than 5 times.

2. Title optimization: The main title contains core keywords, and subtitles clarify product features and advantages.

3. Content structure: Adopt clear H1-H3 title hierarchy, with tables and lists to enhance readability.

4. Technical parameters: Detailed technical indicators improve professionalism and search relevance.

5. Application cases: Real scenario cases enhance user trust and content credibility.