ToggleProduct Overview
The KITOZER Modular UPS 200kVA is a high-capacity online system delivering 200kW at power factor 1.0 for large data centers, enterprise IT, and industrial critical loads. Each hot-swappable power module is 25kVA or 25kW, and the frame accepts up to 8 modules for 200kVA capacity with N+X redundancy. The architecture supports parallel frames for even larger systems.
Built for 24/7 mission-critical operation, the KITOZER unit uses transformer-less high-frequency topology with IGBT inverter technology and digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window allows the UPS to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 requirements and avoid utility penalty charges. The unit is CE certified and complies with IEC 62040 safety and EMC standards for global deployment.
Intelligent battery management performs periodic self-tests every 30 days, monitors cell voltage, charge current, and ambient temperature, and compensates charge voltage to maximize battery service life. The front panel color LCD displays real-time input voltage, output voltage, load percentage, battery capacity, temperature, and active alarms, rotating automatically for rack or tower orientation. Optional SNMP and Modbus TCP integration fits DCIM, building management, and NMS platforms for remote alarm email, scheduled shutdown, and historical logging. Three-year standard warranty with optional extended coverage available from KITOZER factory.
Technical Specifications
Frame capacity 200kVA, module rating 25kVA or 25kW PF 1.0. Input 380, 400, or 415V three phase, range 304 to 478VAC. Output 380, 400, or 415V three phase, online efficiency 96.5 percent. Up to 8 modules per frame. Parallel frames supported. Dimensions 1000 by 1200 by 2000 mm, weight 1500 kg frame.
Input power factor greater than 0.99, total harmonic distortion less than 3 percent, online efficiency optimized for low operating cost and reduced cooling load. Output voltage regulation within plus or minus 1 percent ensures clean power for sensitive IT loads and industrial control equipment. Overload rating supports motor inrush currents and transient events. Operating temperature 0 to 40 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Event log stores up to 512 records for troubleshooting and compliance reporting. Color LCD with backlight and intuitive menu navigation for daily operation.
Application Scenarios
Deployments include large data centers, colocation facilities, financial trading floors, hospital central plants, and semiconductor fabs. Parallel frames allow multi-megawatt redundancy.
Additional use cases include government back-office systems, media editing workstations, security operations centers, university computer labs, and small manufacturing work cells. The wide input voltage range allows deployment in regions with unstable grid voltage where line-interactive units would constantly switch to battery. The pure sine-wave output is safe for active PFC power supplies found in modern servers, storage arrays, and high-end network appliances. External battery cabinets are chosen when generator start-up time is long or not available, ensuring orderly shutdown of virtualization clusters and critical workloads.
Key Advantages
Modular pay-as-you-grow scales from 25 to 200kVA per frame. N+X redundancy within and across frames. Hot-swap modules reduce service time to minutes.
Built-in surge and EMI filtering protects connected equipment from lightning transients and conducted noise. Compact design saves valuable rack or floor space in data center and IT room environments. Hot-swappable batteries allow replacement without powering down the load, reducing service time to minutes. The optional SNMP card integrates with existing DCIM and BMS platforms without additional hardware cost. Comprehensive event log and waveform capture simplify troubleshooting for maintenance teams and reduce mean time to repair.
Installation and Maintenance Advice
Install on reinforced concrete floor. Coordinate upstream switchgear with UPS fault rating. For parallel frames, use dedicated paralleling cables and identical firmware.
Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life and optimal UPS performance. Download the KITOZER PowerShut software for graceful shutdown of connected servers during extended outages. Perform a full discharge test every 6 months to verify runtime and battery health. Recharge batteries for 8 hours after installation or replacement. Update firmware via USB in maintenance window and keep the event log exported before upgrades. Keep spare fans and fuses on site for fast replacement. Label bypass positions and emergency stop buttons clearly for maintenance teams.
Price
From $68,000 per frame. Custom configurations and bulk orders are welcome. Contact KITOZER engineering team for detailed quotation, factory lead time, and shipping options worldwide. Power modules, battery cabinet, and parallel options quoted separately.
KITOZER provides comprehensive technical support including pre-sales consultation, system design guidance, factory training, and on-site commissioning assistance. Spare parts inventory is maintained for fast shipment worldwide. Extended warranty plans are available for mission-critical installations. Contact KITOZER engineering team for custom configurations, high-altitude derating, and specific application requirements.