ToggleProduct Overview
The KITOZER 60kVA modular UPS is a fully redundant, hot-swappable power platform built for growing data centers and mission-critical IT loads. The 60kVA frame accepts up to four 15kVA power modules, plus a bypass and control module, and supports N plus X redundancy where X can be set to one or two spare modules for fault tolerance. Because every power module is hot-swappable, maintenance technicians can remove and replace a faulty module in under five minutes while the load stays online, dramatically reducing mean time to repair. The modular architecture also lets operators start at 30kVA capacity and scale to 60kVA without replacing the frame, preserving capital investment and matching power spend to actual IT growth. A common DC bus shares battery energy across all modules, and the parallel control logic synchronizes inverter outputs so the system behaves as a single coherent UPS.
Technical Specifications
Frame rated 60kVA, each power module 15kVA / 13.5kW, power factor 0.9. Input three-phase 380 to 415VAC, range 323 to 477VAC, PFC 0.99, THDi less than 3 percent. Output three-phase 380 to 415VAC, regulation +/-1 percent, THDv less than 2 percent linear, less than 4 percent nonlinear. Efficiency 96.5 percent online, 99 percent ECO. Battery cabinet supports up to 40 blocks of 12V 100Ah VRLA, giving 20 minutes at full load. 10-inch touchscreen, RS485 Modbus, SNMP, Web HMI, dry-contact relay. Frame dimensions 600 x 1100 x 2000 millimeters, weight 450 kilograms without batteries. CE, IEC 62040 certified. Hot-swap modules, front service access. Overload 110 percent for 60 minutes, 125 percent for 10 minutes. Audible alarm 60 dB at 1 meter. Operating temperature 0 to 40 degrees Celsius. Up to four modules fit the standard frame, and a separate battery cabinet connects via front terminals.
Application Scenarios
Typical deployments include medium data centers with 30 to 60 racks, hospital critical IT and imaging systems, university data rooms, financial transaction processing, and media production render farms. The on-demand scalability is especially valuable for facilities with phased build-out plans, where initial IT load is unknown or expected to grow over 3 to 5 years. It is also chosen by colocation providers who need to add capacity per tenant without taking the hall offline, by pharmaceutical manufacturing IT rooms running batch-control systems, and by broadcasting master control facilities that cannot tolerate even brief interruptions. The N plus X configuration means a single module failure never drops the load, which is essential for 24/7 operations.
Advantages and Features
Hot-swappable power modules eliminate planned downtime for module replacement. N plus X redundancy ensures that even two simultaneous module failures do not drop the load. The common battery bus shares energy across all modules, improving battery utilization. A built-in maintenance bypass allows the entire UPS frame to be isolated for service while the load runs on utility. Digital control architecture supports remote firmware updates and predictive diagnostics that flag capacitors and fans approaching end of life. High efficiency at partial load keeps operating costs low during early low-load years. The Web HMI offers role-based access control and email alerts, and the SNMP integration feeds power data into the existing DCIM platform. Spare-parts inventory is simplified because one 15kVA module covers every KITOZER modular frame from 30kVA to 120kVA.
Installation and Maintenance Recommendations
Position the frame on a level concrete floor rated above 800 kilograms per square meter. Leave 1 meter front clearance for module insertion and 0.8 meter rear for cable bending radius. Use correctly sized input and output breakers with proper short-circuit coordination. Commission the system with KITOZER engineers to verify module synchronization, redundancy logic, and battery charging profile. Perform quarterly visual checks of module status LEDs and fan airflow. Annual preventive maintenance includes capacitor ripple test, fan replacement schedule review, and battery impedance scan. Keep one spare power module on site for critical installations to guarantee four-hour response capability. Keep the battery room at 20 to 25 degrees Celsius and ensure ventilation follows VRLA battery code requirements. Document module serial numbers and firmware versions in the site register, and label each module slot for quick field identification.
Delivery and Warranty
The modular frame ships on a wooden crate with power modules, bypass module, and control module packed separately to protect sensitive electronics. Standard lead time is 4 to 6 weeks, and sea freight to major ports takes 25 to 35 days. KITOZER provides a 3-year warranty on the frame and power modules and a 2-year warranty on batteries, with optional extended coverage up to 5 years. Factory engineers support commissioning, parallel configuration, and acceptance testing. A recommended spares package includes one power module, one control board, and one fan tray, ensuring a four-hour restoration target for critical sites. Full English documentation, CE certificates, and factory test reports accompany every shipment.
Price
From $16,800/pc frame. Additional 15kVA power modules from $3,950/pc. Contact +86 13922289957 for modular configuration and pricing.