KITOZER
KITOZER

KITOZER Modular UPS 60kVA N+X Redundancy Data Center

Product Overview

The KITOZER Modular UPS 60kVA is a high-density online system delivering 60kW at power factor 1.0 for mid-size data centers and critical IT rooms. Each hot-swappable power module is 15kVA or 15kW, and the frame accepts up to 4 modules for 60kVA capacity with N+1 or N+X redundancy. The architecture allows operators to start with 30kVA and scale to 60kVA as load grows.

Built for 24/7 mission-critical operation, the KITOZER unit uses transformer-less high-frequency topology with IGBT inverter technology and digital signal processor control for precise output voltage and frequency regulation. The wide input voltage window allows the UPS to ride through deep sags and swells without switching to battery, extending battery life and reducing cycling. Input power factor correction greater than 0.99 and total harmonic distortion less than 3 percent help the site comply with IEEE 519 requirements and avoid utility penalty charges. The unit is CE certified and complies with IEC 62040 safety and EMC standards for global deployment.

Intelligent battery management performs periodic self-tests every 30 days, monitors cell voltage, charge current, and ambient temperature, and compensates charge voltage to maximize battery service life. The front panel color LCD displays real-time input voltage, output voltage, load percentage, battery capacity, temperature, and active alarms, rotating automatically for rack or tower orientation. Optional SNMP and Modbus TCP integration fits DCIM, building management, and NMS platforms for remote alarm email, scheduled shutdown, and historical logging. Three-year standard warranty with optional extended coverage available from KITOZER factory.

Technical Specifications

Frame capacity 60kVA, module rating 15kVA or 15kW PF 1.0. Input 380, 400, or 415V three phase, range 304 to 478VAC. Output 380, 400, or 415V three phase, online efficiency 96.5 percent. Up to 4 modules per frame. Dimensions 600 by 1000 by 1600 mm, weight 450 kg frame.

Input power factor greater than 0.99, total harmonic distortion less than 3 percent, online efficiency optimized for low operating cost and reduced cooling load. Output voltage regulation within plus or minus 1 percent ensures clean power for sensitive IT loads and industrial control equipment. Overload rating supports motor inrush currents and transient events. Operating temperature 0 to 40 degrees Celsius, relative humidity 5 to 95 percent non-condensing. Event log stores up to 512 records for troubleshooting and compliance reporting. Color LCD with backlight and intuitive menu navigation for daily operation.

Application Scenarios

Common deployments include enterprise data centers, cloud edge nodes, hospital IT, manufacturing execution systems, and large corporate offices. The modular design is chosen when load growth is expected but upfront capital must be minimized.

Additional use cases include government back-office systems, media editing workstations, security operations centers, university computer labs, and small manufacturing work cells. The wide input voltage range allows deployment in regions with unstable grid voltage where line-interactive units would constantly switch to battery. The pure sine-wave output is safe for active PFC power supplies found in modern servers, storage arrays, and high-end network appliances. External battery cabinets are chosen when generator start-up time is long or not available, ensuring orderly shutdown of virtualization clusters and critical workloads.

Key Advantages

Pay-as-you-grow scales from 30 to 60kVA. N+X redundancy within frame. Hot-swap power modules reduce service time. 96.5 percent efficiency lowers energy cost.

Built-in surge and EMI filtering protects connected equipment from lightning transients and conducted noise. Compact design saves valuable rack or floor space in data center and IT room environments. Hot-swappable batteries allow replacement without powering down the load, reducing service time to minutes. The optional SNMP card integrates with existing DCIM and BMS platforms without additional hardware cost. Comprehensive event log and waveform capture simplify troubleshooting for maintenance teams and reduce mean time to repair.

Installation and Maintenance Advice

Install on reinforced concrete floor. Slide modules into slots until latched. Use external battery cabinet with fused cables. Keep firmware identical across modules.

Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life and optimal UPS performance. Download the KITOZER PowerShut software for graceful shutdown of connected servers during extended outages. Perform a full discharge test every 6 months to verify runtime and battery health. Recharge batteries for 8 hours after installation or replacement. Update firmware via USB in maintenance window and keep the event log exported before upgrades. Keep spare fans and fuses on site for fast replacement. Label bypass positions and emergency stop buttons clearly for maintenance teams.

Price

From $18,500 per frame. Power modules and battery cabinet quoted separately.

KITOZER provides comprehensive technical support including pre-sales consultation, system design guidance, factory training, and on-site commissioning assistance. Spare parts inventory is maintained for fast shipment worldwide. Extended warranty plans are available for mission-critical installations. Contact KITOZER engineering team for custom configurations, high-altitude derating, and specific application requirements.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart