KITOZER
KITOZER

KITOZER MRI Shielded Room: 100dB Faraday Cage For 3T Scanner Suite

Product Overview

KITOZER MRI shielded room is a purpose-built Faraday cage protecting 1.5 T and 3 T magnetic resonance imaging suites from external RF interference and, equally important, containing the scanner RF energy inside the room. MRI scanners transmit powerful RF pulses at the Larmor frequency, and even microvolt-level leakage can corrupt image SNR or disrupt nearby electronics. KITOZER delivers the shield as modular welded or bolted copper and steel panel systems, engineered to meet FDA and IEC requirements for RF enclosure attenuation. The package includes a shielded waveguide door, filtered penetrations, a shielded observation window, and a built-in Faraday cage for patient monitoring and anesthesia equipment. The result is a compliant, low-maintenance MRI suite that protects image quality and satisfies scanner manufacturer site acceptance criteria.

Technical Specifications

The standard 3 T room measures 6.0 m by 7.0 m by 3.0 m internally and uses a 0.2 mm continuous copper-foil bonded to 2 mm galvanized steel backing panels. Shielding effectiveness exceeds 100 dB from 10 MHz to 1 GHz and 90 dB from 1 to 400 MHz, measured per IEEE 299. The shielded door is 1.5 m by 2.2 m, pneumatically sealed, with copper finger strips on all four sides and a safety interlock that cuts RF amplifier power when opened. A 1.2 m wide copper-clad observation window with leaded glass for radiation shielding integrates into the wall. Mains power enters through a 100 A three-phase MRI-grade filter with 120 dB attenuation; patient monitoring, Ethernet, and fiber feeds pass through qualified bulkheads. All plumbing, HVAC ducts, and light fixtures enter through below-cutoff waveguide.

Application Scenarios

These rooms are installed in hospital radiology departments, diagnostic imaging centers, university research hospitals, and veterinary MRI clinics. They are sized around the specific scanner model, with dedicated equipment rooms, control rooms, and patient changing areas. The shield protects the scanner from ambient RF noise such as pagers, two-way radios, nearby cell towers, and building switching power supplies, while preventing the scanner RF from leaking out and disrupting pacemakers, implanted devices, and sensitive hospital electronics. KITOZER also supplies retrofit shielding upgrades for existing imaging suites, where the copper foil is bonded into walls and ceilings without full demolition.

Advantages and Features

The copper-foil bonded construction provides superior long-term corrosion resistance compared with welded steel-only shields, critical in the humid, chemically cleaned hospital environment. The modular panel system shortens on-site installation to under three weeks, minimizing imaging department disruption. Pneumatic door sealing guarantees consistent finger-strip compression, which is essential because door seams are the most common failure point in MRI cages. KITOZER coordinates directly with scanner manufacturers to validate site acceptance test (SAT) data, removing integration risk for the hospital. All penetrations are pre-tested and labeled, so biomedical engineering staff can trace every service entry.

Installation and Maintenance Recommendations

Prepare a rigid, isolated foundation and prevent any rebar from bridging the shield to the building structure. Bond the copper foil continuously at every panel joint with approved tinned-copper braid, and ground the room to the hospital earthing system at a single point. During installation, keep the copper foil covered to prevent oxidation from handling. After installation, perform a full IEEE 299 attenuation sweep in the presence of the scanner manufacturer. Monthly, inspect door finger strips for compression and clean contact surfaces with approved contact cleaner. Annually, re-test shielding effectiveness at door seams, filter entries, and waveguide ports. Keep the room humidity below 60 percent and avoid hanging anything magnetic or conductive on the shield walls.

Configuration and Options

The KITOZER MRI shield package is engineered around the specific scanner model. The standard 3 T room includes the copper-foil shell, pneumatic shielded door, observation window, 100 A three-phase filter, patient monitoring bulkheads, and a SAT-ready attenuation dossier. Optional upgrades cover 7 T high-field rooms with additional magnetic shielding, RF door with intercom and camera, shielded patient handwashing stations, in-wall equipment racks, and a separate shielded equipment room for the RF amplifier and gradient cabinets. KITOZER also supplies retrofit kits for existing suites, where copper foil is bonded into walls and ceilings without full demolition. Provide scanner manufacturer and model, room dimensions, and the equipment-room layout at inquiry time, and the company will issue a coordinated drawing that satisfies the scanner site-planning manual. Spare finger strips, filter cartridges, and door seals are held in regional stock.

Warranty and Support

KITOZER warrants the MRI shield for five years on copper foil and panels, and two years on door, filters, and window. Factory SAT documentation ships with each suite, and the company coordinates with scanner manufacturers during site acceptance. Spare finger strips, door seals, and filters are held in regional stock.

Price

From $78,000 per MRI suite. Contact +86 13922289957 for scanner-specific layout and SAT package.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart