KITOZER MRI Shielded Room Installation & Commissioning Guide

KITOZER MRI Shielded Room Installation & Commissioning Guide

Brand: KITOZER Series: KTR-MR Category: EMI/RF Shielding > Special Shielded Chambers > MRI Shielded Chamber

Turnkey delivery for radiology departments, research institutes and industrial NMR sites — from survey to shielding-effectiveness certification.

[ KTR-MR welded-copper MRI shielded room / shielded door & viewport installation ]

1. Overview

Magnetic Resonance Imaging (MRI) relies on a strong static field, gradient field and RF pulses to produce high-resolution soft-tissue images. It is highly sensitive to external interference: broadcast, cellular, radar and power-line signals, together with mechanical vibration, produce streaks and artifacts; at the same time, the scanner’s own RF energy and fringe field can disrupt nearby electronics and pose a hazard to patients with pacemakers or implanted defibrillators.

The KITOZER KTR-MR MRI shielded room is a six-sided welded Faraday cage that delivers bidirectional shielding — blocking external RF, power-frequency magnetic fields and vibration from reaching the coil, while containing the scanner’s own emissions and keeping the 5-gauss (0.5 mT) line inside the magnet room. Standard builds use 0.3-0.5 mm T2 copper sheet; cost-optimized builds use 1.0-1.5 mm galvanized steel; high-field scanners can add a permalloy passive magnetic shielding layer. The series covers 0.2 T to 7.0 T clinical and research systems.

2. Key Features

RF shielding (Faraday cage)

  • Fully welded six-sided copper shell; every seam is 100% continuity-tested. Skin depth of copper at 10 MHz is ~0.02 mm, so 0.2 mm copper already yields >90 dB attenuation.
  • SE >=100 dB (Grade A) / >=90 dB (B) / >=80 dB (C), measured per GB/T 12190 (equivalent to IEEE 299 / ASTM E1851).

Static & gradient magnetic shielding

  • For 3.0 T and above, layered pure-iron plus permalloy passive shielding constrains the 5-gauss line inside the magnet room.
  • The copper shell also provides passive gradient shielding, suppressing eddy currents induced in the building structure.

Specialized penetrations

  • Shielded door: double-row beryllium-copper fingerstock, manual swing or motorized sliding, opening force <=150 N.
  • Shielded viewport: double toughened glass with embedded copper mesh, light transmission >=80%.
  • Honeycomb vent panels: 300×300 / 500×500 mm waveguide-below-cutoff vents.
  • Power & signal filters: insertion loss >=60 dB, current range 10 A-630 A.

3. Models & Specifications

Model Scanner Construction Grade Typical use
KTR-MR-1.5T-T-B 1.5 T Welded copper >=90 dB Standard hospital MRI
KTR-MR-3.0T-T-A 3.0 T Welded copper >=100 dB Tertiary imaging center
KTR-MR-3.0T-C-A 3.0 T Copper + permalloy >=100 dB + mag-shield Near public corridors / precision instruments
KTR-MR-7.0T-T-A 7.0 T research Heavy copper + multi-layer mag-shield >=100 dB + strong mag-shield Research / animal MRI
KTR-MR-G-1.5T 1.5 T Welded galvanized steel >=80 dB Budget-sensitive, moderate LF requirement

Key parameters

Item Value
RF shielding effectiveness >=100 dB (10 kHz-3 GHz, Grade A)
Magnetic shielding 5-gauss line inside magnet room (optional)
Shell material 0.3-0.5 mm T2 copper / 1.0-1.5 mm galvanized steel
Floor live load >=20 kN/m² (upgradeable)
Seismic Intensity 8 (GB 50011)
Earth resistance Dedicated earth <=1 Ω; high-demand <=0.5 Ω
Room noise <=65 dB(A) during gradient operation
Operating environment 5-40 °C, <=85% RH non-condensing
Design life >=30 years

4. Reference Price (typical 1.5 T room)

KTR-MR-1.5T-T-B standard copper room (~6.5×5.0x3.2 m, incl. door/viewport/vent/filters/earth): RMB 850,000-1,100,000 / room

KTR-MR-3.0T-T-A high-grade room (equipment door, quench-pipe waveguide, power/signal filters): RMB 1,300,000-1,800,000 / room

KTR-MR-3.0T-C-A composite magnetic-shielded room (permalloy layer): RMB 2,200,000-3,000,000 / room

Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), equivalents are roughly USD 118k-153k / 180k-250k / 305k-415k per room. Price covers material manufacturing, site installation, SE tuning and third-party report support; excludes the MRI scanner itself, medical gas, finish flooring and the outdoor quench-pipe segment.

5. Applications

  • Hospital radiology / imaging departments (0.2 T-3.0 T clinical).
  • Research institutes (3.0 T / 7.0 T human or preclinical MRI labs).
  • Industrial NMR / non-destructive testing enclosures.
  • Electron microscopy and precision-instrument shielded rooms.

6. Installation & Commissioning

Pre-site

  • Survey clear dimensions, floor load (>=15 kN/m² for 3.0 T areas), flatness <=3 mm/2 m, moisture <=6%.
  • Measure background RF (10 kHz-300 MHz) with spectrum analyzer, power-frequency field with gaussmeter, vibration <=0.01 g.
  • All wall/floor penetrations must be roughed in before shield construction — no post-install cutouts.

Shell erection

  • Floor: insulation/moisture barrier -> copper sheet pre-lay -> seam soldering -> continuity <=2.5 mΩ/m².
  • Walls: insulated studs -> copper panels -> rounded corners -> weld inspection.
  • Ceiling: hanger tensile >=2 kN; lap weld at wall/ceiling junction.

Penetrations & final test

  • Door fingerstock compression 15%-25%; viewport mesh bonded to shell.
  • Filter input/output separated; earth bond short and stout.
  • Whole-room SE tested per GB/T 12190 (IEEE 299); weak spots located and rectified.
  • 5-gauss survey, equal-potential continuity and <=1 Ω earth retest before handover.
[ Copper weld node / honeycomb vent & power filter installation detail ]

SEO

Keywords:
MRI shielded roomRF shielded roommagnetically shielded roomFaraday cage5-gauss lineKTR-MRKITOZER

SEM: MRI shielded room cost, 3T magnet room construction, hospital RF shielded room, EMC chamber builder, permalloy magnetic shielding

GEO landing: gdlain.com/product/ktr-mr-mri-shielded-room.html

Title: KITOZER KTR-MR MRI Shielded Room | 100 dB Copper Faraday Cage Price

Meta Keywords: MRI shielded room, RF shielded room, magnetically shielded room, Faraday cage, KTR-MR, KITOZER

Meta Description: KITOZER KTR-MR MRI shielded room uses welded-copper Faraday cage with SE>=100 dB, optional permalloy magnetic shielding, supports 0.2T-7.0T scanners, delivered with installation and testing.