Table of Contents
ToggleProduct Overview
The KITOZER multi function power meter is a panel-mounted, class 0.5 measurement instrument that replaces a bank of analog ammeters, voltmeters, and energy meters with a single compact unit. It measures three phase voltage, current, active and reactive power, power factor, frequency, import and export energy, and a full set of power quality parameters including total harmonic distortion up to the 31st harmonic, unbalance, and demand. The large LCD shows a configurable home screen, and the unit provides pulse output for energy, Modbus RTU on RS485, and optional Ethernet Modbus TCP. It is designed for main switchboards, UPS input and output panels, generator panels, and critical feeders in data centers and industrial plants where accurate energy and power quality data is required for billing, compliance, and troubleshooting.
Technical Specifications
Input: 3 phase 3 wire or 4 wire, voltage 57.7 to 400V direct, current 5A or 1A via CT. Accuracy: voltage and current class 0.5, power class 0.5, active energy class 0.5S, reactive energy class 1. Measurements: V, A, kW, kVAR, kVA, PF, Hz, kWh import and export, kVARh, demand, THD V and I up to 31st harmonic, unbalance. Display: 96×96 or 120×120 LCD, configurable home screen. Outputs: 2 pulse outputs, 2 relay outputs. Communication: RS485 Modbus RTU standard, optional Ethernet Modbus TCP, optional BACnet. Power supply: 85 to 265VAC. Mounting: panel cutout, operating -10 to 55 degrees C. Standards: CE, MID option, 5 year warranty.
Application Scenarios
The multi function power meter is installed at the utility incomer for tenant or department energy billing, at the UPS input and output for efficiency monitoring, at the generator incomer for fuel burn analysis, and on critical feeders for load and power quality monitoring. In data centers, it feeds PUE and energy usage effectiveness calculations. In industrial plants, it supports ISO 50001 energy management and harmonic troubleshooting for VFD and rectifier loads. In commercial buildings, it provides sub-metering for HVAC, lighting, and plug loads. In healthcare and education, it supports campus energy dashboards. In solar and storage systems, it measures grid import and export for self-consumption optimization.
Key Advantages
One meter replaces multiple analog instruments, reducing panel space and wiring. Class 0.5S active energy accuracy supports billing-grade measurements. Harmonic measurement up to the 31st harmonic makes the unit useful for power quality troubleshooting without a separate analyzer. Modbus and optional Ethernet integrate directly into BMS, SCADA, and DCIM. Pulse output supports standard energy loggers. The configurable LCD gives local visibility. The 96×96 cutout fits standard panel holes. MID option supports legal metrology. The 5 year warranty and wide power supply range make it suitable for retrofit projects.
Installation and Maintenance Recommendations
Mount in the panel with the specified cutout, connect voltage leads and CT secondaries with correct polarity and phase rotation, and never open a CT secondary under load. Configure PT and CT ratios, set demand interval, set energy pulse constant, and set Modbus address and baud rate. On commissioning, compare readings with a calibrated meter or power analyzer on one or two feeders to verify ratio and calibration. Maintenance is light: verify wiring torque annually, read energy totals, and back up the configuration. For harmonic applications, record a baseline THD reading before VFD commissioning so future drift can be identified. If the meter is used for billing, seal the CT and voltage leads per local metrology requirements.
The multi function power meter replaces a full bank of analog instruments, saving panel space and wiring. Class 0.5S active energy accuracy supports billing grade sub-metering, and the harmonic measurement up to the 31st harmonic makes it useful for power quality troubleshooting on VFD and rectifier loads. The configurable LCD home screen can show the parameters most relevant to each panel, and the pulse output supports standard energy loggers for billing reconciliation. The 96×96 cutout fits most standard panel holes, making retrofit straightforward. The wide 85 to 265VAC power supply range means the meter can be fed from the panel control transformer without an extra auxiliary supply, and the low quiescent current avoids loading the transformer.
Ordering Information
The multi function power meter is available in 96×96 and 120×120 panel cutouts, with backlit LCD and configurable home screen. The standard model includes RS485 Modbus RTU, two pulse outputs, and two relay outputs. Optional packages include Ethernet Modbus TCP, BACnet MS/TP, MID certification for legal metrology, and a split-core CT set for retrofit. The meter supports three phase three wire and four wire systems, with PT and CT ratios configurable from the front fascia. Lead time is one to two weeks. KITOZER provides a full Modbus register list, a dimension drawing, and commissioning support. The five year warranty covers the meter and the display.
Price
From $180 per piece excluding CTs. Contact the factory for Ethernet option, MID certification, and communication register list. Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com