Table of Contents
Toggle1. System Overview
The KITOZER noise reduction equipment system focuses on source noise control and transmission suppression for industrial noise. It integrates three core products: noise isolation rooms, machine room noise barriers and industrial noise enclosures. Combining acoustic simulation, composite material and intelligent control technologies, it delivers a full-scenario noise reduction solution covering sound source enclosure, transmission path blocking and space sound insulation.
Designed under an integrated concept of sound insulation + sound absorption + damping + sealing + heat dissipation, the system delivers stable noise reduction of 20–40dB(A) for various noise sources (air compressors, fans, generators, stamping equipment, etc.) and environments (indoor/outdoor, high-temperature/humid, high-dust). It helps enterprises comply with the GBZ 1-2010 Industrial Enterprise Noise Hygiene Standard and pass environmental acceptance inspections, while improving working conditions, protecting employees’ hearing and boosting production efficiency.

KITOZER Integrated Noise Reduction Unit
2. System Composition
The system consists of three modules: core noise reduction units, auxiliary functional units and intelligent control units, which work together to achieve efficient noise reduction and safe equipment operation.
Core Noise Reduction Units
- Noise Isolation Rooms: Fixed, modular and mobile enclosures, equipped with sound-insulated walls, sealed doors, soundproof windows and silenced ventilation systems.
- Machine Room Noise Barriers: Vertical, folded and curved steel structures, composed of sound insulation panels, sound absorption layers, shock-absorbing bases and fixed brackets.
- Industrial Noise Enclosures: Fully enclosed, semi-enclosed and detachable housings, featuring outer sound insulation plates, middle damping layers, inner sound-absorbing materials, access doors and observation windows.
Auxiliary Functional Units
- Ventilation & Heat Dissipation Module: Impedance composite silencers, forced ventilation fans and temperature-controlled heat dissipation channels, resolving the conflict between equipment heat dissipation and noise reduction.
- Sealing & Vibration Isolation Module: High-temperature resistant sealing strips, rubber shock absorbers and damped spring bases to block structural sound transmission and resonance vibration.
- Lighting & Observation Module: Explosion-proof LED lights, double-layer tempered glass soundproof windows and emergency lighting to ensure internal visibility and operational safety.

Front Elevation Drawing of Noise Reduction Equipment
Intelligent Control Unit
- Environmental Monitoring Terminal: Noise, temperature/humidity and vibration sensors to collect real-time operational data.
- Intelligent Control Cabinet: PLC control, touch screen and remote communication modules to realize automatic linkage control of ventilation, lighting and heat dissipation.
- Alarm System: Acoustic & visual alarms for over-temperature, excessive noise and equipment faults, supporting local and remote early warning to guarantee equipment safety.
3. System Classification
3.1 Classification by Product Type
Noise Isolation Rooms
- Fixed Noise Isolation Room: For long-term fixed high-noise equipment (foundry workshops, metal processing production lines). Sound insulation ≥35dB(A), service life over 10 years.
- Modular Noise Isolation Room: Assembled with light steel keels and standardized plates, suitable for equipment requiring regular maintenance (transformers, boilers). Sound insulation 30–35dB(A), quick disassembly and reuse.
- Mobile Noise Isolation Room: Lightweight design with casters for temporary noise reduction (construction site crushers, test stations). Sound insulation 25–30dB(A), flexible mobility.
Machine Room Noise Barriers
- Vertical Noise Barrier: Simple structure with low cost, applicable to machine rooms with basic noise reduction demands.
- Folded Noise Barrier: Folded structure extends sound wave transmission paths, boosting noise reduction effect by 5–8dB(A), ideal for high-noise machine rooms.
- Curved Noise Barrier: Curved top design for sound reflection and aesthetic appearance, for machine room peripherals with landscape requirements.

Workshop Production of Sound Insulation Panels
Industrial Noise Enclosures
- Fully Enclosed Noise Enclosure: Fully sealed around noise sources with only silenced ventilation outlets, noise reduction 25–40dB(A). For high-noise equipment such as air compressors and generators.
- Semi-Enclosed Noise Enclosure: Covers key noise radiation areas for easy operation and inspection, noise reduction 15–25dB(A). For motors, pumps and other equipment requiring frequent patrols.
- Detachable Noise Enclosure: Modular bolted connection for fast disassembly, suitable for equipment with regular major maintenance or temporary noise reduction. Noise reduction 20–30dB(A).
3.2 Classification by Noise Reduction Grade
- Basic Grade (Low Configuration): Noise reduction 20–25dB(A). For low-noise equipment (small fans, water pumps), meeting basic environmental protection standards.
- Standard Grade (Medium Configuration): Noise reduction 25–35dB(A). For medium-noise equipment (air compressors, punching machines), complying with industrial workshop noise standards.
- High-Efficiency Grade (High Configuration): Noise reduction 35–40dB(A). For high-noise equipment (generators, crushers, high-pressure exhaust outlets), satisfying strict environmental requirements and precision testing environments.
4. System Schematic Principles

On-site Assembly of Modular Noise Isolation Room
- Noise Isolation Room Principle: Noise source → sound-insulated wall (outer steel plate + middle damping layer + inner sound-absorbing cotton) → sealed door/window → silenced ventilation system → external environment. Shock-absorbing bases suppress structural sound transmission, and temperature control systems link ventilation and heat dissipation.
- Machine Room Noise Barrier Principle: Noise from machine room equipment propagates through air → sound insulation panel (metal plate + damping layer) → sound absorption layer (centrifugal glass wool) → sound attenuation. Bottom shock absorbers block vibration transmission, while curved/folded tops reflect residual sound waves.
- Industrial Noise Enclosure Principle: Equipment noise → enclosure (outer plate + damping + inner sound-absorbing material) → sealing structure → silencer → external environment. Access doors and observation windows facilitate operation; forced ventilation systems cool equipment; shock-absorbing bases cut vibration noise.
5. Full System Configuration Lists (Low / Medium / High Configuration)
5.1 Basic Grade List (20–25dB(A) Noise Reduction)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Basic Fixed Noise Isolation Room | KITOZER-GYF-1001 | Custom size (≤10㎡); 50mm wall (1.5mm galvanized steel + 25mm centrifugal glass wool); sound insulation 20–25dB(A); single sealed door (900×2100mm); single-layer tempered glass window (600×800mm); natural ventilation + simple silencer | 1 | Set | KITOZER | Indoor low-noise workshop, basic noise reduction |
| 2 | Basic Vertical Machine Room Noise Barrier | KITOZER-PZ-L1001 | Height 2m, custom width; 1.2mm galvanized steel panel; 20mm rock wool sound absorption layer; 10mm rubber shock pad; sound insulation 20–25dB(A) | 1 | Set | KITOZER | Machine room zoning, block noise transmission |
| 3 | Basic Semi-Enclosed Industrial Noise Enclosure | KITOZER-ZB-B1001 | Custom size for small equipment; 1.5mm galvanized steel + 20mm sound-absorbing cotton; sound insulation 20–25dB(A); 1 access door, 1 observation window; natural ventilation | 1 | Set | KITOZER | Small fans, water pumps and other low-noise equipment |
| 4 | Simple Ventilation Silencer | KITOZER-XS-J1001 | 300×300mm; 10dB(A) noise reduction; galvanized steel + sound-absorbing cotton | As required | Pcs | KITOZER | Matched with ventilation outlets of isolation rooms/enclosures |
| 5 | Rubber Shock Pad | KITOZER-JD-X1001 | 10mm thickness; load ≤500kg/㎡; damping coefficient 0.3 | As required | Pcs | KITOZER | Under equipment to reduce structural sound transmission |
5.2 Standard Grade List (25–35dB(A) Noise Reduction)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Standard Modular Noise Isolation Room | KITOZER-GYM-2001 | Custom size (10–50㎡); 80mm wall (2mm galvanized steel + damping coating + 40mm high-density centrifugal glass wool); sound insulation 25–35dB(A); double sealed soundproof door (1200×2100mm); double-layer hollow tempered glass window (800×1000mm); forced fan + impedance composite silencer; explosion-proof LED lighting; damped spring base | 1 | Set | KITOZER | Industrial workshops, machine rooms with standard noise reduction demands |
| 2 | Standard Folded Machine Room Noise Barrier | KITOZER-PZ-Z2001 | Height 2.5m, custom width; 2mm galvanized steel + damping layer; 30mm high-density centrifugal glass wool; damped spring shock absorber; sound insulation 25–30dB(A); fold angle 120° | 1 | Set | KITOZER | High-noise machine rooms for enhanced noise reduction |
| 3 | Standard Fully Enclosed Industrial Noise Enclosure | KITOZER-ZB-Q2001 | Custom size for medium equipment; 2mm galvanized steel + damping coating + 30mm gradient-density sound-absorbing cotton; sound insulation 25–35dB(A); 2 access doors, 2 observation windows; forced fan + labyrinth silencer; simple temperature control switch; rubber shock absorbers | 1 | Set | KITOZER | Air compressors, punching machines, generators and other medium high-noise equipment |
| 4 | Impedance Composite Silencer | KITOZER-XS-K2001 | 500×500mm; 20dB(A) noise reduction; galvanized steel + micro-perforated plate + sound-absorbing cotton | As required | Pcs | KITOZER | Matched with forced ventilation systems to cut air flow noise |
| 5 | Damped Spring Shock Absorber | KITOZER-JD-T2001 | Load 500–2000kg; natural frequency ≤5Hz; damping ratio 0.25 | As required | Pcs | KITOZER | Under equipment/isolation rooms to suppress low-frequency vibration |
| 6 | Double-Layer Hollow Tempered Soundproof Window | KITOZER-C-G2001 | 800×1000mm; 5+5mm hollow glass; sound insulation 25dB(A); aluminum alloy sealed frame | As required | Pcs | KITOZER | For observation on isolation rooms/enclosures, balancing sound insulation and visibility |
5.3 High-Efficiency Grade List (35–40dB(A) Noise Reduction)
è¡¨æ ¼
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-Efficiency Fixed Noise Isolation Room | KITOZER-GYG-3001 | Custom size (≥50㎡); 120mm wall (3mm galvanized steel + double damping coating + 60mm ultra-high-density centrifugal glass wool + perforated plate); sound insulation 35–40dB(A); airtight double-seal soundproof door (1500×2100mm); triple-layer tempered glass window (1000×1200mm); intelligent temperature-controlled fan + composite silencer (30dB(A) reduction); explosion-proof LED + emergency lighting; adjustable damped spring base; PLC intelligent control cabinet + remote monitoring; Class A fireproof material; mildew & corrosion resistant | 1 | Set | KITOZER | Precision testing labs, high-noise workshops, key environmental protection zones |
| 2 | High-Efficiency Curved Machine Room Noise Barrier | KITOZER-PZ-H3001 | Height 3m, custom width; 3mm galvanized steel + double damping layer; 50mm ultra-high-density centrifugal glass wool + resonance sound absorption structure; adjustable damped spring shock absorber; sound insulation 30–35dB(A); curve radius 1.5m; outdoor fluorocarbon anti-corrosion coating | 1 | Set | KITOZER | Large machine rooms, factory boundaries with high noise reduction & landscape requirements |
| 3 | High-Efficiency Detachable Industrial Noise Enclosure | KITOZER-ZB-G3001 | Custom size for large equipment; 3mm galvanized steel + double damping coating + 50mm gradient-density sound-absorbing cotton + micro-perforated resonance plate; sound insulation 35–40dB(A); 3 airtight sealed access doors; 3 triple-glass observation windows; intelligent linked ventilation + labyrinth silencer (25dB(A) reduction); high-precision temperature/humidity sensor + auto temperature control; combined damping shock system; local touch control + remote communication; fully detachable modular design; salt spray test ≥500h anti-corrosion | 1 | Set | KITOZER | Large generators, crushers, high-voltage equipment, precision instruments |
| 4 | Intelligent Temperature-Controlled Ventilation System | KITOZER-TF-Z3001 | Custom air volume 1000–5000m³/h; temperature control range 25–40℃; PLC auto linkage + manual switch; low-noise explosion-proof fan; matched high-efficiency silencer | As required | Set | KITOZER | Dedicated for high-efficiency isolation rooms/enclosures, balance heat dissipation and noise reduction |
| 5 | PLC Intelligent Control Cabinet | KITOZER-KZ-P3001 | ≥8 control loops; 7-inch touch screen; RS485 + Ethernet communication; noise/temperature/humidity/vibration monitoring; acoustic & visual alarm + remote push notification; AC220V/380V power supply | 1 | Set | KITOZER | System intelligent control, remote monitoring & fault early warning |
| 6 | Adjustable Damped Spring Shock Absorber | KITOZER-JD-K3001 | Load 2000–5000kg; natural frequency ≤3Hz; damping ratio 0.3; ±50mm height adjustment; stainless steel + anti-corrosion coating | As required | Pcs | KITOZER | For heavy equipment/isolation rooms, suppress low-frequency vibration |
6. Full Product Technical Parameters
6.1 Noise Isolation Room Technical Parameters

Section Drawing of Noise Isolation Room
Basic Fixed Noise Isolation Room
- Custom size (≤10㎡)
- Wall structure: 50mm thickness (1.5mm galvanized steel + 25mm centrifugal glass wool)
- Sound insulation: 20–25dB(A)
- Door: Single sealed door (900×2100mm)
- Window: Single-layer tempered glass window (600×800mm)
- Ventilation: Natural ventilation + simple silencer
- Fire rating: Class B
- Operating temperature: -10℃ ~ 50℃
Standard Modular Noise Isolation Room

Modular Noise Isolation Room On-site
- Custom size (10–50㎡)
- Wall structure: 80mm thickness (2mm galvanized steel + damping coating + 40mm high-density centrifugal glass wool)
- Sound insulation: 25–35dB(A)
- Door: Double sealed soundproof door (1200×2100mm)
- Window: Double-layer hollow tempered glass window (800×1000mm)
- Ventilation: Forced fan + impedance composite silencer
- Lighting: Explosion-proof LED (illuminance ≥200lx)
- Shock absorption: Damped spring base (load 500–2000kg)
- Fire rating: Class A
- Operating temperature: -20℃ ~ 60℃
High-Efficiency Fixed Noise Isolation Room
- Custom size (≥50㎡)
- Wall structure: 120mm thickness (3mm galvanized steel + double damping coating + 60mm ultra-high-density centrifugal glass wool + perforated plate)
- Sound insulation: 35–40dB(A)
- Door: Airtight double-seal soundproof door (1500×2100mm)
- Window: Triple-layer hollow tempered glass window (1000×1200mm)
- Ventilation: Intelligent temperature-controlled fan + composite silencer (30dB(A) reduction)
- Lighting: Explosion-proof LED + emergency light (illuminance ≥300lx)
- Shock absorption: Adjustable damped spring base (load 2000–5000kg)
- Control: PLC intelligent cabinet + remote monitoring
- Fire rating: Class A
- Mildew & corrosion resistance: Salt spray test ≥500h
- Operating temperature: -30℃ ~ 70℃
6.2 Machine Room Noise Barrier Technical Parameters

Intelligent Control Platform for Noise Reduction Equipment
Basic Vertical Noise Barrier
- Height: 2m, custom width
- Panel: 1.2mm galvanized steel
- Sound absorption layer: 20mm rock wool (density 48kg/m³)
- Shock absorption: 10mm rubber shock pad
- Sound insulation: 20–25dB(A)
- Anti-corrosion: Ordinary anti-rust paint
- Operating temperature: -10℃ ~ 50℃
Standard Folded Noise Barrier
- Height: 2.5m, custom width
- Panel: 2mm galvanized steel + 2mm damping layer
- Sound absorption layer: 30mm high-density centrifugal glass wool (80kg/m³)
- Shock absorption: Damped spring shock absorber (load 500–2000kg)
- Sound insulation: 25–30dB(A)
- Fold angle: 120°
- Anti-corrosion: Outdoor anti-rust paint
- Operating temperature: -20℃ ~ 60℃
High-Efficiency Curved Noise Barrier
- Height: 3m, custom width
- Panel: 3mm galvanized steel + total 4mm double damping layer
- Sound absorption layer: 50mm ultra-high-density centrifugal glass wool (120kg/m³) + resonance sound absorption structure
- Shock absorption: Adjustable damped spring shock absorber (load 2000–5000kg)
- Sound insulation: 30–35dB(A)
- Curve radius: 1.5m
- Anti-corrosion: Outdoor fluorocarbon coating (salt spray test ≥500h)
- Operating temperature: -30℃ ~ 70℃
6.3 Industrial Noise Enclosure Technical Parameters
Basic Semi-Enclosed Noise Enclosure
- Custom size for small equipment
- Enclosure structure: 1.5mm galvanized steel + 20mm sound-absorbing cotton (48kg/m³)
- Sound insulation: 20–25dB(A)
- Access door: 1 piece (800×1800mm)
- Observation window: 1 piece (500×600mm, single glass)
- Ventilation: Natural ventilation
- Shock absorption: Rubber shock pad
- Operating temperature: -10℃ ~ 50℃
Standard Fully Enclosed Noise Enclosure

Noise Enclosure Applied to Stamping Machine
- Custom size for medium equipment
- Enclosure structure: 2mm galvanized steel + 2mm damping coating + 30mm gradient-density sound-absorbing cotton (80kg/m³)
- Sound insulation: 25–35dB(A)
- Access door: 2 pieces (1000×2000mm)
- Observation window: 2 pieces (600×800mm, double glass)
- Ventilation: Forced fan + labyrinth silencer (20dB(A) reduction)
- Temperature control: Simple switch (25–40℃)
- Shock absorption: Rubber shock absorber (load 500–2000kg)
- Operating temperature: -20℃ ~ 60℃
High-Efficiency Detachable Noise Enclosure
- Custom size for large equipment
- Enclosure structure: 3mm galvanized steel + total 4mm double damping coating + 50mm gradient-density sound-absorbing cotton (120kg/m³) + micro-perforated resonance plate
- Sound insulation: 35–40dB(A)
- Access door: 3 airtight sealed pieces (1200×2000mm)
- Observation window: 3 pieces (800×1000mm, triple glass)
- Ventilation: Intelligent linked ventilation + labyrinth silencer (25dB(A) reduction)
- Temperature control: High-precision sensor (±0.5℃) + auto regulation
- Shock absorption: Combined damping shock system (load 2000–5000kg)
- Control: Local touch screen + remote communication (RS485/Ethernet)
- Customization: Fully detachable modular design, reusable over 5 disassembly cycles
- Anti-corrosion: Salt spray test ≥500h
- Operating temperature: -30℃ ~ 70℃
7. Full Product Application Scope

Finished Indoor Noise Isolation Room
7.1 Noise Isolation Room Application Scope
- Industrial Production: Metal processing workshops, foundries, stamping workshops, textile plants, high-noise equipment rooms (air compressor rooms, generator rooms)
- Precision Testing: Electronic component silent testing, motor noise testing, instrument calibration rooms, acoustic labs, semi-anechoic chambers
- Commercial & Office: Office building equipment rooms, data centers, live streaming studios, recording rooms, soundproof meeting rooms, hospital hearing test rooms
- Environmental & Public: Factory boundary noise reduction, sewage treatment machine rooms, pump stations, transformer substations, airport equipment rooms, rail transit equipment cabins
7.2 Machine Room Noise Barrier Application Scope
- Industrial Machine Rooms: Factory workshop equipment rooms, air compressor rooms, generator rooms, fan/pump/crusher rooms
- Data Centers: Server rooms, UPS rooms, air conditioning rooms, cabinet partition noise control
- Factory & Industrial Parks: Workshop equipment zones, factory boundary separation, noise barriers between production and rest areas
- Public Facilities: Transformer substations, heat exchange stations, water supply & drainage pump stations, gas pressure regulating stations, service station machine rooms along highways
7.3 Industrial Noise Enclosure Application Scope
- General Machinery: Air compressors, fans, water pumps, motors, reducers, stamping/milling/lapping/crushing/ball mill machines
- Power Equipment: Diesel/gasoline generators, gas turbines, steam turbines, boilers, transformers, high-voltage switch cabinets
- HVAC & Refrigeration: Cooling towers, water chillers, outdoor air conditioning units, heat pumps, ventilation exhaust fans
- Special Equipment: Auto parts test benches, engine test stands, precision instruments, food processing, packaging & printing machinery
8. Full Product Advantages
8.1 Core Functional Features
- High-Efficiency Noise Reduction: Composite structure of sound insulation + absorption + damping + sealing. Basic grade 20–25dB(A), standard grade 25–35dB(A), high-efficiency grade 35–40dB(A), meeting diverse environmental and production standards.
- Customized Design: Fully non-standard customization. One-on-one solution design based on equipment size, noise characteristics, site conditions (indoor/outdoor, temperature/humidity/dust) and noise reduction targets, adapting to complex scenarios.
- Modular Structure: Standard & high-efficiency grades adopt bolted modular assembly without welding, cutting construction period by 50%. Detachable and reusable for low long-term maintenance costs.
- Balanced Heat Dissipation & Noise Reduction: Integrated intelligent ventilation system matched with impedance composite/labyrinth silencers to cool equipment without sacrificing noise reduction performance, avoiding over-temperature shutdowns.
- Vibration Suppression: Specialized shock absorption systems (rubber pads / damped springs / combined dampers) block vibration transmission and low-frequency resonance, cutting structural sound transmission and improving overall noise reduction.
- Safe & Durable: Main body made of galvanized/stainless steel for rust & corrosion resistance; Class A fireproof, high temperature, moisture and mildew resistant. All key joints sealed to withstand harsh industrial environments with service life over 10 years.
- Intelligent Control: High-efficiency grade equipped with PLC intelligent system to monitor noise, temperature, humidity and vibration in real time, auto-link ventilation, lighting and heat dissipation, supporting remote monitoring and fault alarms to lower operation costs.
8.2 Customization & Service Advantages
- One-Stop Customization: Full-process service including on-site acoustic survey, noise testing, solution design, manufacturing, installation, commissioning and after-sales maintenance to precisely match customer demands.
- OEM/ODM Support: Accept OEM & ODM processing, custom brand logos, specifications and packaging to protect client brand rights.
- Strict Confidentiality: Sign non-disclosure agreements to protect client technical parameters, design drawings and project data with dedicated document management to prevent information leakage.
- Spot Inventory: Core components of basic & standard grades stocked for fast delivery, shortening lead time for urgent projects.
- Full Series Coverage: Complete product line of isolation rooms, barriers and enclosures across low/medium/high configurations, covering all noise levels and equipment sizes.
- Customizable Technical Parameters: Tailor performance for special requirements (noise reduction above 40dB(A), 80℃ high temperature, 95% RH high humidity, narrow space limits) to break standard performance boundaries.
9. Bid Evaluation Technical Parameters (* marks core bid-winning indicators)
9.1 Noise Isolation Room Bid Parameters
- *Sound Insulation: Basic ≥20dB(A), Standard ≥25dB(A), High-Efficiency ≥35dB(A)
- *Wall Thickness: Basic ≥50mm, Standard ≥80mm, High-Efficiency ≥120mm
- *Main Material: Galvanized steel (Basic ≥1.5mm, Standard ≥2mm, High-Efficiency ≥3mm) + high-density centrifugal glass wool (Basic ≥48kg/m³, Standard ≥80kg/m³, High-Efficiency ≥120kg/m³)
- *Door Structure: Standard double sealed door, High-Efficiency airtight double-seal door, sound insulation ≥25dB(A) (Standard) / ≥35dB(A) (High-Efficiency)
- *Window Glass: Standard double-layer hollow tempered glass (5+5mm), High-Efficiency triple-layer glass, sound insulation ≥25dB(A) (Standard) / ≥30dB(A) (High-Efficiency)
- *Ventilation Silencing Capacity: Standard ≥20dB(A), High-Efficiency ≥30dB(A)
- *Shock Absorber Type: Standard damped spring shock absorber, High-Efficiency adjustable damped spring shock absorber, natural frequency ≤5Hz (Standard) / ≤3Hz (High-Efficiency)
- *Fire Rating: ≥Class A
- *Anti-Corrosion Grade: High-Efficiency grade salt spray test ≥500h
- *Intelligent Control: High-Efficiency grade equipped with PLC cabinet supporting remote monitoring & fault alarms
9.2 Machine Room Noise Barrier Bid Parameters
- *Sound Insulation: Basic ≥20dB(A), Standard ≥25dB(A), High-Efficiency ≥30dB(A)
- *Height: Basic ≥2m, Standard ≥2.5m, High-Efficiency ≥3m
- *Panel Material: Galvanized steel (Basic ≥1.2mm, Standard ≥2mm, High-Efficiency ≥3mm) + damping layer (Standard ≥2mm, High-Efficiency ≥4mm)
- *Sound Absorption Layer Density: Basic ≥48kg/m³, Standard ≥80kg/m³, High-Efficiency ≥120kg/m³
- *Shock Absorber Type: Standard damped spring shock absorber, High-Efficiency adjustable damped spring shock absorber
- *Structure Form: High-Efficiency curved design, Standard fold angle ≥120°
- *Anti-Corrosion Grade: High-Efficiency outdoor fluorocarbon coating, salt spray test ≥500h
9.3 Industrial Noise Enclosure Bid Parameters
- *Sound Insulation: Basic ≥20dB(A), Standard ≥25dB(A), High-Efficiency ≥35dB(A)
- *Enclosure Thickness: Basic ≥50mm, Standard ≥80mm, High-Efficiency ≥120mm
- *Main Material: Galvanized steel (Basic ≥1.5mm, Standard ≥2mm, High-Efficiency ≥3mm) + gradient-density sound-absorbing cotton (Basic ≥48kg/m³, Standard ≥80kg/m³, High-Efficiency ≥120kg/m³)
- *Access Door Sound Insulation: Standard ≥25dB(A), High-Efficiency ≥35dB(A)
- *Ventilation Silencing Capacity: Standard ≥20dB(A), High-Efficiency ≥25dB(A)
- *Shock Absorption System: Standard rubber shock absorber, High-Efficiency combined damping system with load ≥2000kg
- *Detachability: High-Efficiency fully modular design, reusable over 5 disassembly cycles
- *Temperature Control Precision: High-Efficiency ±0.5℃
10. Full Product Targeted Solutions
10.1 High-Noise Industrial Workshop Noise Control Solution
- Pain Points: Workshop equipment (air compressors, punching machines, generators) generate 90–110dB(A) noise, failing environmental acceptance and harming employee hearing; poor equipment heat dissipation and severe vibration.
- Solution Combination: High-efficiency fully enclosed industrial noise enclosures + high-efficiency curved machine room noise barriers + intelligent ventilation & heat dissipation system + combined damping shock absorption system
- Implementation Effect: Equipment noise reduced below 70dB(A), 35–40dB(A) noise reduction; vibration suppression rate ≥90%; equipment temperature stabilized at 25–40℃ without overheat shutdowns; workshop meets environmental standards and passes inspection.
- Advantages: Dual noise control via source enclosure + transmission path blocking; intelligent temperature control balances heat dissipation and noise reduction; modular installation without production interruption; long service life suitable for harsh workshop environments.
10.2 Silent Environment Solution for Precision Testing Labs
- Pain Points: Electronic/motor testing requires background noise ≤30dB(A); external noise interference, unstable temperature/humidity affecting testing accuracy, demand for airtight sound insulation and precise environmental control.
- Solution Combination: High-efficiency fixed noise isolation rooms + triple-layer soundproof windows + airtight soundproof doors + PLC intelligent temperature & humidity control system + high-efficiency silenced ventilation system
- Implementation Effect: Indoor background noise ≤25dB(A), 35–40dB(A) sound insulation; temperature & humidity precision ±0.5℃, ±5% RH; ventilation volume meets testing equipment demands without noise interference for stable, accurate test data.
- Advantages: Ultra-high sound insulation to meet precision testing standards; intelligent environmental control ensures test accuracy; fire & moisture resistant for lab use; modular design for expandable space.
10.3 Data Center & Machine Room Noise Control Solution
- Pain Points: Servers, UPS and air conditioning equipment generate 85–95dB(A) noise disturbing adjacent offices; dense equipment creates high heat dissipation pressure with limited space.
- Solution Combination: Standard folded machine room noise barriers + standard semi-enclosed industrial noise enclosures + forced ventilation silencers + damped spring shock absorbers
- Implementation Effect: Machine room noise reduced below 75dB(A), 25–30dB(A) noise reduction; normal equipment air intake & exhaust without overheat alarms; reduced vibration cuts server hardware loss; office area noise ≤60dB(A) to improve staff comfort and operation efficiency.
- Advantages: Space separation + partial equipment noise reduction suited for dense machine rooms; balanced noise reduction and heat dissipation for stable equipment operation; modular installation with short construction cycle and moderate cost; easy maintenance for 7×24h continuous operation.
10.4 Outdoor Equipment (Cooling Tower / Outdoor AC Unit) Noise Reduction Solution
- Pain Points: Outdoor equipment generates 80–90dB(A) noise disturbing surrounding residents; exposure to wind, sun and rain leads to corrosion, requiring weather resistance and high noise reduction.
- Solution Combination: High-efficiency detachable industrial noise enclosures + high-efficiency curved outdoor noise barriers + waterproof & dustproof sealing system + fluorocarbon anti-corrosion coating
- Implementation Effect: Equipment noise reduced below 65dB(A), 30–35dB(A) noise reduction; anti-corrosion weather resistance with salt spray test ≥500h adapting to harsh outdoor conditions; detachable design for easy equipment maintenance; aesthetic appearance matching surrounding landscapes.
- Advantages: Outdoor dedicated anti-corrosion design with long service life; noise reduction meets residential environmental standards; detachable reuse lowers maintenance costs; stable structure with wind & rain resistance.
11. Full Product Application Cases
11.1 Noise Reduction Project for an Auto Parts Manufacturing Workshop
- Project Background: 10 stamping machines and 5 air compressors producing 95–105dB(A) noise, causing employee hearing damage and failed environmental acceptance; severe equipment vibration and poor heat dissipation.
- Product Configuration: 15 sets of KITOZER high-efficiency fully enclosed noise enclosures, 200㎡ high-efficiency curved machine room noise barriers, 15 sets of intelligent ventilation & heat dissipation systems, 15 sets of combined damping shock absorption systems.
- Implementation Effect: Equipment noise dropped to 68–72dB(A), 30–37dB(A) reduction; vibration suppression rate 92%; equipment temperature stabilized at 32–38℃ without shutdowns; one-time environmental acceptance approval, improved working conditions and 15% higher production efficiency.
- Customer Feedback: “KITOZER delivers highly customized solutions with noise reduction far exceeding expectations. The intelligent ventilation solves heat dissipation issues, installation is fast without production downtime, and after-sales support responds promptly – a reliable long-term partner.”
11.2 Precision Motor Testing Lab Project for an Electronics Technology Company
- Project Background: 3 silent testing rooms required with background noise ≤28dB(A); external ambient noise 75–85dB(A); temperature & humidity precision ±1℃, ±10% RH for motor noise & performance testing.
- Product Configuration: 3 sets of 20㎡ KITOZER high-efficiency fixed noise isolation rooms, 12 triple-layer soundproof windows, 6 airtight soundproof doors, 3 sets of PLC intelligent temperature & humidity control systems, 3 sets of high-efficiency silenced ventilation systems.
- Implementation Effect: Stable test room background noise 22–25dB(A), 38–42dB(A) sound insulation; temperature & humidity precision ±0.4℃, ±3% RH; ventilation volume 150m³/h without noise interference for precise test data; one-time project acceptance supporting mass testing demands.
- Customer Feedback: “The isolation room delivers outstanding acoustic performance with background noise lower than expected. The intelligent control system operates reliably, installation cycles are short and workmanship is professional, providing critical support for our R&D testing.”
11.3 Noise Renovation Project for a Large Data Center
- Project Background: 3-floor machine room with dense servers, UPS and air conditioning equipment generating 88–93dB(A) noise disturbing offices and monitoring rooms; high heat dissipation pressure and limited space.
- Product Configuration: 500㎡ KITOZER standard folded machine room noise barriers, 30 sets of standard semi-enclosed industrial noise enclosures, 60 forced ventilation silencers, 120 damped spring shock absorbers.
- Implementation Effect: Machine room noise reduced to 72–76dB(A), 26–31dB(A) noise reduction; normal equipment air temperature without overheat alarms; reduced vibration cuts server hard drive loss; office area noise ≤60dB(A) improving staff comfort and operation efficiency.
- Customer Feedback: “The solution balances noise reduction, heat dissipation and space utilization. Modular installation runs without interrupting machine room operation, noise reduction results are obvious, and regular after-sales inspections guarantee long-term stable operation with high cost performance.”
11.4 Cooling Tower Noise Reduction Project for a Commercial Complex
- Project Background: 8 rooftop cooling towers generating 82–88dB(A) noise triggering residential complaints; high heat dissipation demand in summer with severe outdoor corrosion risks.
- Product Configuration: 8 sets of KITOZER high-efficiency detachable industrial noise enclosures, 150㎡ high-efficiency curved outdoor noise barriers, 8 sets of waterproof & dustproof sealing systems, full fluorocarbon anti-corrosion coating treatment.
- Implementation Effect: Cooling tower noise reduced to 63–67dB(A), 20–25dB(A) noise reduction; unchanged heat dissipation efficiency without summer shutdowns; anti-corrosion performance with no rust after 2 years of operation; zero residential complaints, passed environmental re-inspection with aesthetic appearance matching commercial surroundings.
- Customer Feedback: “The outdoor noise enclosures are reliably manufactured with compliant noise reduction performance. Detachable design simplifies maintenance and superior anti-corrosion treatment prevents deformation under wind and sun. The noise nuisance issue with residents is fully resolved, and we are highly satisfied.”
12. Product Common Faults & Maintenance Specifications
12.1 Common Faults, Troubleshooting & Resolution
- Declined Noise Reduction Effect
- Causes: Aged/damaged sealing strips, loose sound insulation panels, damp & caked sound-absorbing materials, blocked silencers
- Resolution: Replace damaged sealing strips; fasten loose panel bolts; replace damp sound-absorbing cotton; clear debris inside silencers for unobstructed ventilation
- Over-Temperature Equipment Alarm
- Causes: Failed ventilation fan, blocked silencer, air leakage in ventilation ducts, faulty temperature sensor
- Resolution: Inspect fan power & motor, replace defective fans; clear silencer blockages; patch air leakage on ducts; calibrate or replace temperature sensors
- Increased Vibration Noise
- Causes: Aged & failed shock absorbers, loose fixing bolts, uneven equipment base, detached damping layers
- Resolution: Replace aged shock absorbers; tighten all fixing bolts; level equipment base; reattach or repair detached damping layers
- Malfunctioning Intelligent Control System
- Causes: Power failure, abnormal PLC program, damaged sensors, faulty communication wiring
- Resolution: Inspect power supply and wiring; restart PLC or reload programs; replace damaged sensors; inspect communication lines to fix open/short circuits
- Rust & Water Leakage on Outdoor Products
- Causes: Damaged anti-corrosion coating, aged sealing parts, rain backflow, blocked drainage holes
- Resolution: Repair damaged anti-corrosion coating; replace aged sealing components; adjust drainage slope and clear drainage holes; reinforce waterproof sealing to prevent rain backflow
12.2 Daily Maintenance Standards
Daily Inspection
- Check isolation rooms/enclosures/barriers for damage, deformation and rust; inspect sealing strips for integrity and detachment; examine observation window glass for breakage and tight sealing.
- Check ventilation fan operation for abnormal noise & vibration; verify temperature control readings stay within set ranges.
- Inspect indicator lights and touch screen of intelligent control cabinets for active fault alarms.
Weekly Maintenance
- Clean internal & external surfaces of isolation rooms/enclosures to remove dust and oil to avoid corrosion; clear inlet & outlet silencer debris to prevent blockages.
- Tighten all connecting bolts (panels, doors, brackets, shock absorbers); inspect shock absorbers for aging/deformation and replace if necessary.
- Calibrate temperature/humidity/noise sensors for accurate readings; test linkage functions of ventilation, lighting and alarm systems.
Monthly Maintenance
- Inspect sound-absorbing cotton (centrifugal glass wool) for dampness, caking and detachment; replace damp materials and reattach loose filling.
- Lubricate door hinges, locks and slide rails for smooth operation; adjust sealing strip tightness to restore airtight performance if needed.
- For outdoor products: Inspect anti-corrosion coating and repair minor damage; clear drainage holes & troughs to prevent rainwater pooling and rust.
Annual Overhaul
- Fully disassemble and inspect structural components of isolation rooms/enclosures/barriers; replace severely aged, damaged or rusted panels, frames and sealing parts.
- Replace all sound-absorbing materials to restore sound absorption performance; fully inspect shock absorption systems, replace failed shock absorbers and re-level equipment bases.
- Complete overhaul of intelligent control systems, upgrade programs, replace aging electronic components and test remote communication & alarm functions.
- Reapply fluorocarbon anti-corrosion coating to outdoor products for enhanced weather resistance; inspect base fixings and reinforce loose brackets & foundations.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
- Production Base: 20,000㎡ modern standardized steel workshop located in an industrial park with convenient transportation and logistics; constant-temperature production workshop for precision material processing.
- Production Equipment: Over 50 sets of advanced automated machinery including laser cutters, CNC bending machines, precision punching presses, coating production lines, sound-absorbing material filling equipment and modular assembly lines. Full-process automated production from raw material processing to finished assembly boosts efficiency by 60% with machining precision controlled within ±1mm.
- R&D Team: Core R&D team of over 20 senior engineers specializing in acoustic engineering, mechanical design and intelligent control with average industry experience over 10 years. Industry-university research cooperation with renowned university acoustic labs for continuous technical innovation, holding 35 national patents (8 invention patents, 27 utility model patents). Certified by ISO9001 quality system, EU CE and RoHS standards.
- Raw Material Control: All raw materials (galvanized steel, stainless steel, centrifugal glass wool, sealing strips, shock absorbers, electronic components) sourced from top domestic or premium imported brands with strict incoming inspection and batch quality test reports to eliminate unqualified materials.
- Production Capacity & Delivery: Annual output of 1,000 noise isolation rooms, 2,000 noise enclosures and 5,000㎡ noise barriers. Standard orders delivered within 7–15 days, rush orders within 5 days. 5 national warehousing hubs (Guangzhou, Shanghai, Beijing, Chengdu, Wuhan) stock basic & standard products for local fast delivery and shorter lead times.
13.2 After-Sales Service
- One-Stop Service Flow: Full-process service covering on-site survey → solution design → manufacturing → installation commissioning → training handover → after-sales maintenance. Professional engineers respond within 24 hours and arrive on-site within 48 hours nationwide, providing free acoustic survey, noise testing and customized solution design.
- Warranty Commitment: All KITOZER products enjoy 5 years free warranty from acceptance date. Free spare parts replacement and repair for non-artificial damage during warranty period. Core components (intelligent control system, shock absorbers, fans) extended to 8-year warranty. Lifetime technical support and maintenance service with only spare part cost charged post-warranty.
- Installation & Commissioning Service: 10 professional construction teams with over 3 years of noise reduction equipment installation experience execute construction strictly per drawings to guarantee firm assembly, tight sealing and qualified performance. Post-installation free commissioning tests noise reduction, heat dissipation and intelligent control functions until meeting customer standards, with formal acceptance reports provided.
- Operation Training Service: Free 1–2 day on-site training for client operation & maintenance staff upon handover, covering product structure, working principles, daily operation, parameter setting, fault troubleshooting and maintenance standards. Hardcopy operation & maintenance manuals plus electronic documentation provided for independent operation.
- Scheduled Inspection Service: 2 free annual on-site inspections during warranty period for full equipment check, cleaning, fastening and debugging to eliminate hidden faults and extend service life. Exclusive client equipment files record operation status, maintenance history and faults with personalized maintenance recommendations.
- Fast Response Mechanism: National unified after-sales hotline with 24-hour dedicated staff for consultation, repair and complaint handling. Two-tier response system (regional after-sales + headquarters technical support): general faults resolved within 24 hours, major faults with engineers on-site within 48 hours. Remote video/phone guidance for simple fault elimination to reduce production downtime.
14. Conclusion
The KITOZER noise reduction equipment system has long specialized in industrial noise control. With five core strengths – efficient noise reduction, customized design, modular structure, intelligent control and durable quality – we deliver a full product line of noise isolation rooms, machine room noise barriers and industrial noise enclosures for all noise reduction scenarios including industrial workshops, precision testing labs, data centers and outdoor equipment.
Backed by robust R&D strength, advanced production equipment, strict quality control and comprehensive after-sales service, we provide global clients with one-stop noise control solutions to resolve noise pollution challenges, improve working environments, protect employee health and achieve environmental compliance & sustainable development.
Moving forward, KITOZER will continue to innovate acoustic technology, optimize product performance and design, expand application scenarios and upgrade service quality, striving to become the world’s leading industrial noise control equipment supplier and contribute to green industrial development.
15. Search Keywords, SEO & Tags
15.1 Search Keywords
Core Keywords
Noise reduction equipment, industrial noise isolation room, machine room noise barrier, industrial noise enclosure, noise control equipment, industrial noise reduction solution
Long-Tail Keywords
- Noise isolation room: Precision testing noise isolation room, industrial workshop noise isolation room, modular noise isolation room, fixed noise isolation room, mobile noise isolation room, silent test chamber, anechoic chamber
- Machine room noise barrier: Machine room noise reduction barrier, industrial machine room soundproof wall, folded noise barrier, curved noise barrier, outdoor noise barrier
- Industrial noise enclosure: Air compressor noise enclosure, generator noise enclosure, fan noise enclosure, detachable noise enclosure, fully enclosed noise enclosure, semi-enclosed noise enclosure
Scenario Keywords
Workshop noise control, data center noise reduction, precision testing silent environment, outdoor equipment noise reduction, environmental noise renovation, industrial equipment vibration & noise reduction
Technical Keywords
Composite sound insulation structure, damping vibration isolation technology, intelligent silenced ventilation, modular noise reduction equipment, non-standard customized sound insulation equipment
15.2 SEO Optimization Guidelines
Page titles integrate core keywords + brand + application scenarios, e.g. KITOZER Industrial Noise Isolation Room | Precision Testing Silent Chamber | High-Noise Workshop Noise Control Solution
15.3 Tags
Product Tags
#NoiseReductionEquipment #IndustrialNoiseIsolationRoom #MachineRoomNoiseBarrier #IndustrialNoiseEnclosure #NoiseControl #IndustrialNoiseReduction #SilentEquipment #Silencer
Technical Tags
#CompositeSoundInsulation #DampingVibrationIsolation #IntelligentVentilation #ModularDesign #CustomNonStandard #HighEfficiencyNoiseReduction
Application Tags
#WorkshopNoiseReduction #PrecisionTesting #DataCenter #OutdoorNoiseReduction #EnvironmentalRenovation #IndustrialEquipmentProtection
Brand Tags
#KITOZER #IndustrialAcoustics #NoiseControlExpert #SourceNoiseTreatment