KITOZER KTR-WC11 8-Zone Non-Locating Leak Detection Controller

Brand: KITOZER Series: KTR-WC11 Category: Environmental Monitoring / Leak Detection

8-zoneNon-locatingSensing cableRelay output

KITOZER KTR-WC11 8-Zone Non-Locating Leak Controller

1. Overview

The KITOZER KTR-WC11 is an 8-zone non-locating leak detection controller used to monitor leak risks such as AC condensate pipes, underfloor areas and pipe joints in datacenters. Each zone connects to a sensing cable laid along potential leak points on floors, troughs or under air conditioners. When liquid (water or conductive liquid) touches the cable, it bridges the two inner conductors; the controller senses the resistance change, flags that zone, lights the corresponding LED and drives a relay alarm. Non-locating means it tells you which zone leaked, not the exact point—suited to zoned monitoring (one zone per area) at lower cost and simpler installation than locating systems.

The KTR-WC11 mounts on a DIN rail in an environmental monitoring cabinet. The front panel has 8 status LEDs (green normal / red alarm) and a buzzer for local audible-visual alarm. Relay dry contacts (NO/NC selectable) feed into the environmental or DC monitoring platform for remote alarms, SMS push and interlocks (e.g. closing the AC water valve). Power is 12/24 V DC under 5 W. The cable end must have a terminating resistor so the controller can also detect cable breaks (rodent bites, pulls) and alarm against missed leaks.

Typical install: in a datacenter, lay 8 sensing cables under the floor near precision-AC drains and condensate pipes, each covering one zone (under AC, at joints, along the underfloor main trough). Use clips to lay the cable on the floor; connect the near end to a KTR-WC11 input and fit the terminating resistor at the far end. DIN-mount the controller in the monitoring cabinet; wire relay outputs to the host DI module. On a leak, that zone’s red LED lights and the buzzer sounds; the platform receives the zone alarm and pushes SMS to ops. Staff locate the zone by number, then find the exact point.

2. Key Features

8-zone non-locating

  • 8 independent loops.
  • One cable per zone.
  • Zoned “which zone” alarm.
  • Simple, low cost.

Sensing cable

  • Detects water/conductive.
  • Terminating resistor.
  • Break detection.
  • Anti-rodent alarm.

Local alarm

  • 8-zone LED.
  • Green/red.
  • Buzzer.
  • Clear front panel.

Relay output

  • NO/NC dry contacts.
  • To monitoring system.
  • Remote alarm push.
  • Valve interlock.

3. Specifications

Item KTR-WC11 (8-zone non-locating) KTR-WC04 (4-zone) KTR-WC20 (Locating)
Zones 8 4 1 (locating)
Locating Non-locating (zone) Non-locating (zone) Locating (±1 m)
Cable length 100 m/zone 100 m/zone Up to 500 m
Break detection Yes (term. resistor) Yes Yes
Alarm output 8 relay dry contacts 4 relay contacts Relay + RS485
Local indicator 8 LED + buzzer 4 LED + buzzer LCD screen
Power 12/24V DC 12/24V DC 24V DC
Mounting DIN rail DIN rail DIN rail

4. Reference Prices

KTR-WC11 8-zone non-locating controller: Reference USD 83 to 250 / unit (ref. CNY 600 to 1800 at ~7.2)

KTR-WC04 4-zone non-locating controller: Reference USD 56 to 167 / unit (ref. CNY 400 to 1200 at ~7.2)

KTR-WC20 locating controller: Reference USD 278 to 694 / unit (ref. CNY 2000 to 5000 at ~7.2)

Sensing cable (non-locating, per m): Reference USD 2 to 6 / m (ref. CNY 15 to 40 at ~7.2)

Reference only; varies by zone count, cable length and qty. Cable, clips, terminating resistors and power adapter billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Under precision AC leak monitoring.
  • Underfloor condensate/water pipes.
  • Pipe joints and valves.
  • Environmental monitoring linkage.
  • Zoned leak tiered alarm.

6. Installation & Maintenance

Installation

  • DIN-mount controller in cabinet.
  • Lay cable along risk zones.
  • Connect near end to input.
  • Fit terminating resistor at far end.
  • Wire relay to host DI.
  • Power-test each zone.

Maintenance

  • Simulate leak test periodically.
  • Inspect cable for damage.
  • Secure terminating resistor.
  • Check buzzer/LED.
  • Verify relay signal.
  • Log leak history.

7. FAQ

  • Q: Non-locating or locating?
    A: Choose non-locating (KTR-WC11) for zoned monitoring on a budget—it tells which zone. Choose locating (KTR-WC20) when you need the exact point within 1 m; it costs more. Use non-locating for large zoned areas and locating for critical pipe runs.
  • Q: Does the cable detect oil?
    A: Non-locating cables detect conductive liquid (water), not oil or non-conductive liquids. Use an oil-specific cable for oil.
  • Q: Max cable length per zone?
    A: Keep under 100 m per zone; beyond that sensitivity drops. Split into more zones or use locating long-range cable.
  • Q: Too many false alarms?
    A: Cable too near AC outlet condensation can false-alarm. Relocate away from air vents, wipe the cable dry periodically, and keep it clean from dust and moisture.

8. Trend & Selection

Water leaks are a top datacenter risk; a single leak can destroy IT equipment. Leak detection evolved from manual patrol to automated sensing-cable monitoring, from zoned alarms to precise locating. Non-locating controllers, low-cost and easy to install, remain the mainstream for zoned datacenter leak monitoring. Select zone count by number of risk areas; one cable per zone; lay under AC, along pipes and joints; fit terminating resistors for break detection; wire relays into the platform for interlock. The KTR-WC11 provides 8-zone non-locating early warning for datacenter environmental monitoring.

9. Delivery & Service

KITOZER supplies leak-detection kits: based on room layout and risk zones we recommend the KTR-WC11 plus sensing cable, clips, terminating resistors and power adapters, bundled with environmental systems and temp/humidity sensors. Delivery includes controller, cable (to length), resistor and manual; bulk projects provide layout drawings and commissioning guidance. Detection or relay failures under warranty are replaced free.

10. Additional Notes

The common mistake is omitting the terminating resistor. Without it the controller cannot tell cable state—neither break nor leak alarms. Fit the correct resistor at each zone end.

Another pitfall is contaminated cable surface. Dust and moisture on the cable reduce sensitivity or cause false alarms. Wipe the cable dry periodically and keep it clean.

Selection summary: 8-zone non-locating, sensing cable per zone, break detection via resistor, 8 LED + buzzer, relay dry contacts, DIN-rail mount. The KTR-WC11 delivers low-cost, reliable early leak warning for datacenter zones.

SEO Information

Search keywords:leak detection controllernon-locating leak sensor8 zone leakwater leak detectorenvironmental monitoringKTR-WC11KITOZER

SEM keywords:[8 zone leak controller price,non-locating leak supplier,datacenter leak monitor,sensing cable leak,KTR-WC11,KITOZER]

GEO landing page:lain.com.cn/product/ktr-wc11-8-zone-non-locating-leak-controller.html

Title:KITOZER KTR-WC11 8-Zone Non-Locating Leak Detection Controller

Meta Keywords:leak detection controller,non-locating leak sensor,8 zone leak,water leak detector,environmental monitoring,KTR-WC11,KITOZER

Meta Description:KITOZER KTR-WC11 8-zone non-locating leak controller with sensing cable, relay alarm output, for datacenter environmental monitoring.

Anchor: KITOZER · Environmental Monitoring

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart