KITOZER
KITOZER

KITOZER Novec 1230 Clean Agent: 60L Cylinder For High Value Assets

KITOZER Novec 1230 clean agent gas suppression system model NV-60 uses fluorinated ketone FK-5-1-12, a next-generation clean extinguishant that combines the rapid fire-fighting performance of HFC-227ea with the environmental profile of inert gas. Novec 1230 has zero ozone depletion potential, a 5-day atmospheric lifetime, and a global warming potential of 1, satisfying the strictest environmental regulations coming into force worldwide. Each 60 liter cylinder stores 72 liters of liquid agent at 2.5 megapascal superpressurized with nitrogen, achieving design concentration of 4.2 to 5.9 percent in 10 seconds. The system is ideal for high-value asset protection where environmental compliance and equipment safety are both mandatory.

Product Overview

The KITOZER NV-60 package includes a 60 liter cylinder, pilot-operated valve with solenoid actuator, flexible high-pressure hose, check valve, discharge piping, calibrated nozzles, detection line, and a gas suppression control panel. The panel provides cross-zone smoke and heat detection, 30-second pre-discharge delay, audible and visual alarms, abort switch, and interfaces with HVAC shutdown and door holders. Because Novec 1230 is stored as a liquid with nitrogen superpressure, the cylinder footprint is roughly half that of an equivalent IG541 system, making it attractive for retrofit projects where space is limited.

Technical Specifications

Agent Novec 1230, FK-5-1-12, C6F12O. Cylinder volume 60 liters. Storage pressure 2.5 megapascal at 20 degrees Celsius, superpressurized with nitrogen. Agent charge per cylinder 72 liters equal to 87 kilograms. Design concentration 4.2 to 5.9 percent by volume. Discharge time 10 seconds. Cylinder material manganese steel. Valve pilot operated, solenoid 24 volt DC. Piping high-pressure steel. Nozzle pressure range 0.6 to 1.6 megapascal. Control panel two detection circuits, cross-zone, 30 second delay, abort, RS485. ODP zero. GWP 1. Atmospheric lifetime 5 days. Certifications CCCF, ISO 9001, NFPA 2001, GB 25972. Cylinder hydro test 10 years. Warranty 24 months from commissioning.

Application Scenarios

Novec 1230 is specified for data center server rooms, electrical switchrooms, UPS and battery rooms, control rooms, museum and gallery protection, library archives, telecommunications equipment rooms, industrial process cabinets, and any high-value enclosure where environmental regulations exclude HFCs. The 60 liter cylinder covers 50 to 70 cubic meters at 5.0 percent concentration. Multiple manifolded cylinders cover larger spaces. Engineers select Novec 1230 when the protected room has limited floor space, when future regulatory risk on HFCs is a concern, and when a 10-second discharge is required.

Advantages and Features

Novec 1230 has zero ozone depletion and near-zero global warming potential, avoiding future regulatory phase-out risk. The 10-second discharge prevents fire spread in energized electrical cabinets. The liquid agent vaporizes completely, leaving no residue on servers or artwork. The agent is safe for use in occupied spaces during the 30-second delay, with a no-observed-effect concentration well above design concentration. The 60 liter cylinder footprint fits tight mechanical rooms. KITOZER provides full hydraulic calculation and concentration verification per NFPA 2001.

Installation and Maintenance Recommendations

Install cylinders upright in a ventilated enclosure between 0 and 50 degrees Celsius. Verify room leakage rate. Install pressure vent relief panels. Inspect cylinder pressure monthly; 10 percent drop requires recharge. Test detection semi-annually. Hydro test cylinders every 10 years. Keep spare solenoid coils and seals. Train staff on abort procedure. Log all inspections.

System Integration

The NV-60 panel integrates with the building fire alarm through supervised circuits, shutting down HVAC, closing fire dampers, releasing door holders, and activating alarms inside and outside the protected space. The 30-second pre-discharge delay is sufficient because Novec 1230 is safe for occupied spaces at design concentration. A manual release box and abort switch are installed outside the door, and the panel sends dry contacts to the BMS for pre-discharge, discharge, and fault conditions. Because the agent is stored as a liquid with nitrogen superpressure, the piping network is sized for 2.5 megapassa class fittings, and KITOZER provides a full hydraulic calculation per NFPA 2001. The detector zoning diagram, release matrix, and enclosure integrity report are delivered as a package, so the MEP consultant can hand the system to the fire authority without supplementary engineering. Post-discharge, the room is aired with fresh air and the cylinders are recharged; servers and artwork can be restarted immediately because the agent leaves no residue and does not conduct electricity. The 60 liter cylinder footprint is roughly half that of an equivalent IG541 system, which is why KITOZER recommends Novec 1230 for retrofit projects where mechanical room floor space is constrained. The agent is accepted by major insurance loss-prevention agencies and is listed for use in normally occupied spaces at the 4.2 to 5.9 percent design concentration. KITOZER also provides the regulatory documentation package needed for green building certification.

Price

From 5,400 US dollars per 60 liter charged cylinder including valve, solenoid, and mounting. Complete system quoted per room calculation. Contact KITOZER for sizing and regulatory documentation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top