Table of Contents
ToggleProduct Overview
The KITOZER Novec 1230 clean agent fire suppression system uses fluorinated ketone liquid that discharges as a rapidly vaporizing gas to protect high-value enclosed spaces without harming people, equipment, or the environment. Novec 1230, also known as FK-5-1-12 or perfluorohexanone, has an atmospheric lifetime of less than five days, zero ozone depletion potential, and a global warming potential of roughly one, making it the most climate-friendly halocarbon clean agent in production today. The agent is stored as a liquid in pressurized cylinders, discharges within 10 seconds, and suppresses flame by absorbing heat and interrupting the chemical chain reaction. KITOZER offers the Novec 1230 system as both cabinet units for small rooms and as pipe network systems for larger volumes. It is particularly popular in data centers, control rooms, and telecom hubs where owners want modern environmental credentials alongside proven extinguishing performance.
Technical Specifications
KITOZER Novec 1230 cylinders are available in 40 L, 70 L, 100 L, and 120 L nominal volumes, charged to 2.5 MPa with nitrogen superpressurization at 20 degrees Celsius. Typical design concentration is 4.5 percent by volume for Class A surfaces and 5.5 to 6 percent for Class B liquid fires, well below the no-observed-adverse-effect level of 10 percent, which gives personnel a comfortable safety margin. Discharge time is less than 10 seconds for cabinet units and less than 20 seconds for piped systems. The cylinder valve is brass with nickel plating, fitted with a solenoid actuator, manual pull, pressure gauge, and burst disc. Piping uses schedule 40 black steel with grooved or threaded joints rated for 4.5 MPa, and nozzles are stainless steel with anti-corrosion coating. Operating temperature range is 0 to 50 degrees Celsius, and the system is certified to ISO 14520, EN 15004, and NFPA 2001 standards.
Applications
KITOZER Novec 1230 is deployed in enterprise data centers, co-location halls, server closets, telephone exchanges, banking server rooms, medical imaging suites, power control rooms, offshore electrical enclosures, and museum electronics galleries. It is also chosen for heritage buildings where owner groups require a clean agent that meets current green-building targets, and for industrial process areas where small amounts of residue would disrupt precision manufacturing. Because the agent is electrically non-conductive and leaves no oily film, it is safe for racks of servers, uninterruptible power supply cabinets, switchboards, and industrial control panels.
Advantages and Features
The KITOZER Novec 1230 system delivers four practical benefits. First, the ultra-short atmospheric lifetime satisfies the most demanding corporate sustainability policies and avoids future regulatory phase-out risk. Second, because the agent is stored as a liquid, cylinder weight is lower than equivalent inert gas systems, reducing structural load on upper floors. Third, the low design concentration means less agent mass per cubic meter, lowering long-term refill cost. Fourth, the agent is optically clear, has no irritating odor, and does not displace oxygen, so the 30-second evacuation delay is comfortable for occupants. KITOZER also offers integrated detectors, control panels, and remote status monitoring as a single package, simplifying procurement and ensuring all components are factory matched.
Installation and Maintenance Recommendations
Position cylinders in a dedicated release room with vibration isolation, adequate ventilation, and a temperature held between 15 and 30 degrees Celsius to slow agent degradation. Support pipe runs on rigid hangers and pressure-test the network to 1.5 times working pressure before introducing cylinders. During installation, keep nozzle outlets at least 200 mm below the ceiling and at least 1 meter from air-conditioning supply diffusers to avoid dilution. Commissioning requires a verified room integrity test showing that leakage area is within the design envelope, otherwise concentration will not hold for the required 10-minute hold time. Service the system by inspecting gauges monthly, weighing cylinders annually, and replacing the agent every 15 years or after discharge. KITOZER recommends keeping a spare charged cylinder on site to minimize downtime after activation. Price starts from $3,480 per 70 L cabinet unit.
Ordering and Factory Support
When specifying a KITOZER Novec 1230 system, supply the protected volume, the fuel classification, and the required hold time, typically 10 minutes. KITOZER will confirm the design concentration, calculate the agent mass, and select cylinder sizes from the standard range. The factory ships pre-charged cylinders with certified weight tags, complete manifolds for multi-cylinder arrays, and a commissioning test report. Because Novec 1230 is a licensed agent, KITOZER supplies refills through certified distributors and provides traceability documentation for each batch. On-site support includes a pressure-decay test, coordination of a room integrity door fan test, and operator training for the facility maintenance team. KITOZER also offers a remote monitoring add-on that transmits gauge pressure, loop status, and discharge events to a cloud dashboard, allowing facility managers to track system health across multiple sites from a single browser.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com