The KITOZER Novec 1230 fire suppression system is engineered for lithium-ion battery energy storage rooms and containers. It combines early gas and smoke detection with a clean-agent discharge that floods the battery compartment in under 10 seconds, suppressing thermal runaway before it propagates to adjacent racks. Novec 1230 is a colorless, electrically non-conductive fluid that leaves no residue, so it does not damage the battery electronics after discharge and the rack can be inspected and restarted with minimal cleanup.
Table of Contents
ToggleProduct Overview
KITOZER designs the system as a pre-piped skid with one or more Novec 1230 cylinders, a manifold, and a network of stainless steel nozzles routed above each battery rack. The detection loop uses aspirating smoke detectors, H2 and CO gas sensors, and NTC temperature sensors, all wired to a fire panel that can also send alarms to the building or container monitoring system. When two independent detectors confirm a fire, the panel triggers the discharge via a solenoid valve, closes the ventilation dampers, and cuts non-safety power to the room. Manual release buttons are provided at the entrance for crew override.
Technical Specifications
Agent: 3M Novec 1230, clean agent, zero ozone depletion. Design concentration 4.5 percent by volume for lithium-ion Class A and C fires. Discharge time less than 10 seconds. Cylinder pressure 25 bar at 21 degrees Celsius. Cylinder sizes 10, 18, 40, and 120 liter. Detection: aspirating smoke, H2, CO, NTC temperature, two-out-of-two logic. Fire panel: 4 loops, 24V DC, dry contact outputs. Compliance: EN 15004, NFPA 2001, GB 25972. Operating temperature minus 20 to plus 55 degrees Celsius. KITOZER five-year warranty, 15-year cylinder design life.
Application Scenarios
This system is installed inside 20-foot and 40-foot battery containers, in walk-in battery rooms at data centers, and in telecom huts that house lithium backup racks. It is also used in C and I storage cabinets that sit inside customer electrical rooms, where water-based sprinklers would be unacceptable. Integrators choose Novec over water or foam because the agent is safe for electronics and leaves no cleanup, and because it meets the lithium-ion detection requirements of most local fire authorities.
Key Advantages
Clean-agent suppression means the battery rack can often be inspected and returned to service after discharge, instead of being written off by water damage. Multi-sensor detection catches early thermal runaway at the gas stage, long before smoke or flame appears, which is critical for lithium batteries. The pre-piped skid ships fully assembled, so on-site work is limited to anchoring, electrical, and final nozzle aiming. The fire panel integrates with the container EMS, so the plant operator sees the alarm on the same dashboard as the PCS and BMS.
Installation and Maintenance
Mount the cylinders in a dedicated cabinet outside the battery compartment, and route the stainless piping to nozzles above each rack. Verify that the nozzle coverage meets the design concentration calculation provided by KITOZER. Commissioning includes a gas leak test on the piping, a detector walk test, and a discharge simulation. Annual maintenance includes checking cylinder weight and pressure, replacing detectors at the recommended interval, and updating the fire panel firmware. Keep the cylinder room ventilated and above freezing, and post the appropriate Novec safety signs at the entrance.
Price
From $4,800 per skid for a 20-foot container. Contact KITOZER for room-sized systems and local fire authority approvals.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com