ToggleKITOZER KTR-ODF48 48-Port Fiber Distribution Frame
Brand: KITOZER Series: KTR-ODF48 Category: Data Center Engineering / Fiber Cabling
48-port ODFRack mountSC/FC/LCSplice trayKTR-ODF48
1. Overview
In room low-voltage systems, fiber is the backbone transmission medium. Between the carrier fiber entrance and the core switch optical ports, a distribution management device is needed to connect outside plant cable to indoor patch cords: that is the ODF (Optical Distribution Frame). Mounted in the network rack, the front holds an adapter panel (patched to switches) and the back holds splice trays (fused to the incoming cable). A 48-port ODF terminates 48 fibers, covering a mid-size room’s fiber needs. The ODF’s job: here fibers are fused, stored, patched and routed; later re-routing is just a patch cord swap, no re-splicing.
KITOZER KTR-ODF48 is a 19-inch rack-mount 48-port fiber distribution frame. KTR-ODF48-SC: SC duplex adapters, terminates 48 fibers (24 SC duplex ports). KTR-ODF48-FC: FC round adapters, 48 FC ports, for legacy telco networks. KTR-ODF48-LC: LC duplex adapters, 48 LC ports (96 fibers), for high-density DC. 1U high, slide-out design for tray access. Built-in 4 splice trays, 12 fibers per tray, 48 total. Independent cable routing with minimum 30 mm bend radius to protect fibers.
Selection: confirm adapter type (SC square / FC round / LC small-square, matching switch optics); confirm fiber count (48-port SC = 48 fibers, 48-port LC = 96 fibers); confirm singlemode/multimode (adapters are universal, cords and pigtails must match); confirm rack height (1U/2U, 48-port fits 1U). Note: fiber bend radius inside the ODF must stay above 30 mm; tighter bends spike loss or break the fiber.
2. Key Features
Build
- 19-inch rack mount, 1U
- Slide-out splice trays
- Cold-rolled steel, powder coat
- 4 trays x 12 fibers each
Adapters
- SC/FC/LC options
- Ceramic ferrule, insertion loss under 0.2 dB
- Dust caps on all ports
- Singlemode/multimode universal
Management
- Dedicated routing, bend radius over 30 mm
- Splice tray with fiber slack storage
- Rear cable manager
- Clear port numbering labels
3. Specifications
| Item | KTR-ODF48-SC | KTR-ODF48-FC | KTR-ODF48-LC |
|---|---|---|---|
| Adapter | SC duplex | FC round | LC duplex |
| Ports | 24 duplex = 48 fibers | 48 ports = 48 fibers | 48 duplex = 96 fibers |
| Height | 1U | 1U | 1U |
| Splice tray | 4×12 fibers | 4×12 fibers | 4×24 fibers |
| Insertion loss | Under 0.2 dB | Under 0.2 dB | Under 0.2 dB |
| Patch cords | SC-SC/SC-LC | FC-FC/FC-SC | LC-LC/LC-SC |
| Typical use | General rooms | Telco rooms | High-density DC |
4. Reference Prices
KTR-ODF48-SC 48-port SC ODF: Reference USD 25 to 45 / unit (ref. CNY 180 to 320 at ~7.2)
KTR-ODF48-FC 48-port FC ODF: Reference USD 28 to 50 / unit (ref. CNY 200 to 360 at ~7.2)
KTR-ODF48-LC 48-port LC ODF: Reference USD 36 to 63 / unit (ref. CNY 260 to 450 at ~7.2)
Splice tray (12 fibers/layer): Reference USD 2 to 4 / pc (ref. CNY 15 to 30 at ~7.2)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Carrier fiber entrance termination and patching.
- Core switch fiber patch management.
- Data center backbone fiber distribution.
- Enterprise room low-voltage room fiber aggregation.
- FTTX hub fiber allocation.
6. Deployment & Implementation
Rack Mount
- Install in network rack at 1U position
- Fix with M6 rack screws
- Leave 2U gap from patch panel for cable routing
- Ensure slide-out clearance
Splicing
- Pull out ODF, open splice tray
- Enter cable through rear gland
- Strip coating, cleave flat
- Fuse and protect with heat-shrink sleeve
Labeling
- Number every port
- Record cable fiber and purpose
- Label both ends of patch cords
- Maintain a fiber distribution ledger
7. FAQ
- Q: ODF vs fiber terminal box?
A: An ODF is rack-mounted with a front adapter panel (patch cords plug in) and rear splice trays — organized, high capacity (24/48/96 fibers). A terminal box is a small wall/desktop box (8/12/24 fibers) that only splices and protects, with pigtails out directly to equipment, no adapter panel. Use ODF for backbone, terminal boxes for horizontal runs. - Q: How to choose SC/FC/LC?
A: Match your switch optics. Mainstream switches use LC small-square ports (high density) -> LC adapters. Legacy and telco use FC round (screw-lock, won’t loosen) -> FC. SC square is in between (push-pull, low cost). Rule: adapter type must match switch optics, otherwise you need hybrid cords. - Q: How to troubleshoot a broken fiber in the ODF?
A: Use a power meter or visual fault locator (VFL). Shine red laser from one end, check for light at the other. If a port is dark, trace the path — adapter connectors, splice points, tight bends. Most common break points: over-tight bend in splice tray, cracked ceramic ferrule, or cord pinched by the rack door. - Q: How many fibers does a 48-port ODF terminate?
A: Depends on adapter. SC duplex: one port = 2 fibers (TX/RX), 24 ports = 48 fibers. FC: one port = 1 fiber, 48 ports = 48 fibers. LC duplex: one port = 2 fibers, 48 ports = 96 fibers. So a “48-port” LC unit terminates 96 fibers, double the SC version. Check whether it is 48 or 96 fibers.
8. Trend & Selection
DC fiber distribution is moving toward high-density and pre-terminated: MPO/MTP pre-terminated cables end 12 or 24 fibers at once, and high-density ODFs fit 144 or 288 fibers in 1U, reducing field splicing in favor of factory pre-termination. But 48-port ODFs remain the workhorse in small-to-mid rooms — low cost, flexible, field-spliceable. Smart direction: intelligent ODFs with electronic labels that auto-detect which cord is patched to which port. Select by matching adapter to switch optics, slide-out trays, adequate bend radius, and complete labeling.
9. Delivery & Service
KITOZER supplies KTR-ODF48 by adapter type (SC/FC/LC). Each ships with ODF chassis, splice trays, adapters and mounting screws. 1-year warranty; batch projects can bundle pigtails, patch cords and fusion splicing service.
10. Additional Notes
Top mistake: too-tight fiber bends. A sharp corner inside the ODF spikes loss from 0.2 dB to several dB or breaks the fiber. Coil fibers in arcs with bend radius over 30 mm (about a ping-pong ball diameter).
Second pitfall: no labels. With 48 cords patched, nobody remembers which port goes to which switch after six months. Label both ends of every port and cord, e.g. “ODF-01-03 -> Core Switch 1 port 5”. Keep an electronic ledger.
Third blunder: skipping OTDR testing after splicing. A splicer showing under 0.02 dB does not guarantee the whole link. Run an OTDR end to end to check every splice and connector; re-splice any bad point.
Selection summary: adapter matches switch optics, 1U slide-out, bend radius over 30 mm, full labels and ledger, OTDR test after splicing. The ODF is the room’s fiber hub — a neat termination saves years of maintenance.
SEO Information
Search keywords:KTR-ODF48KITOZER
SEM keywords:fiber rack,ODF fiber distribution,48 port ODF,fiber patch panel,rack mount ODF,KTR-ODF48,KITOZER
GEO landing page:lain.com.cn/product/fiber_rack_odf48.html
Title:KITOZER KTR-ODF48 48-Port Fiber Distribution Frame
Meta Keywords:fiber rack,ODF fiber distribution,48 port ODF,fiber patch panel,rack mount ODF,KTR-ODF48,KITOZER
Meta Description:KITOZER KTR-ODF48 48-port rack-mount fiber distribution frame: 19-inch 1U, SC/FC/LC adapters, slide-out splice trays, room cabling management.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com