ToggleKITOZER KTR-ODFU ODF Unit Box / Fiber Distribution Unit
Brand: KITOZER Series: KTR-ODFU Category: Low-Voltage System 2 / ODF Unit
ODF unit boxfiber distributionrack mount ODFsplice trayLC adapter
1. Overview
KITOZER KTR-ODFU is an ODF (Optical Distribution Frame) unit — a rack-mounted fiber management unit installed inside a server rack. When fiber cables enter a rack, they can’t plug directly into servers. They must first be terminated in the ODF unit: cable anchoring → fiber splicing → pigtail storage → adapter mating → patch cord to server. The ODF unit is the rack’s fiber “cross-connect box,” organizing the junction between incoming cable and outgoing patch cords.
Unlike an outdoor fiber cross-connect cabinet (large, floor-standing), the ODF unit is a small rack-mount device: 1U or 2U height, standard 19-inch width, installed directly in the server rack. Capacity ranges 12~48 cores (single/multi-mode), with SC/FC/LC adapters. Three-layer internal structure: front panel adapters (patch cords exit here), middle splice tray (fiber-to-pigtail splicing), rear cable entry (cable anchoring, grounding, bend-radius protection). Pull-out drawer design: slide out for splicing, push back for a neat patch panel.
KTR-ODFU uses cold-rolled steel with black powder coating, matching rack color. Adapter types: SC (square, most common), FC (round, legacy), LC (small square, high density). Splice trays handle 12 cores each, stacked in layers. Every core has a numbered label matching the patch schedule — clear for maintenance.
2. Key Features
Rack-mount design
- 1U/2U standard 19-inch; installs directly in rack.
- Pull-out drawer for convenient splicing access.
- Same height/width as patch panels and cable managers.
Splice + distribution integrated
- Front panel adapters for patch cord mating.
- Middle splice tray: fiber-to-pigtail fusion splice.
- Rear entry: cable anchoring + grounding + bend-radius protection.
High density
- 1U up to 48-core LC duplex (96 fiber strands).
- Modular adapters: SC/FC/LC selectable and swappable.
- Removable splice trays for cleaning and replacement.
Labeling & identification
- Every core numbered, matching patch schedule.
- Adapter color coding (single-mode yellow / multi-mode aqua).
- Label card slots for printed inserts.
3. Specifications
| Item | KTR-ODFU-12 | KTR-ODFU-24 | KTR-ODFU-48 |
|---|---|---|---|
| U Height | 1U | 1U | 2U |
| Capacity | 12 cores | 24 cores | 48 cores |
| Adapter type | SC/FC | SC/FC/LC | LC duplex |
| Splice tray | 1 layer (12c) | 2 layers (24c) | 4 layers (48c) |
| Cable entry | Rear/top | Rear/top | Rear/top+side |
| Material | CR steel 1.0mm | CR steel 1.2mm | CR steel 1.2mm |
| Finish | Powder coat black | Powder coat black | Powder coat black |
| Fiber type | OS2/OM3 | OS2/OM3/OM4 | OS2/OM4 |
4. Reference Prices
KTR-ODFU-12/24 standard ODF unit (12~24 core, 1U, SC adapter, no pigtails): Reference USD 21~56 / unit (ref. CNY 150~400 at ~7.2)
KTR-ODFU-48 high-density ODF unit (48 core, 2U, LC duplex, multi-layer splice): Reference USD 69~167 / unit (ref. CNY 500~1,200 at ~7.2)
Reference only; final quote depends on core count, adapter type (SC/FC/LC), and material thickness. Pigtails, splicing and patch cords billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter rack fiber distribution management.
- Enterprise server room fiber access.
- Building weak-current room fiber-to-desk.
- Telecom equipment room ODF expansion units.
- Surveillance camera fiber access points.
6. Installation & Maintenance
Installation
- Plan ODF position in rack: above/below patch panel, next to cable manager.
- Secure to rack square-hole rails with M6 cage nuts.
- Enter cable from rear; anchor in entry zone; ground shield.
- Strip cable; thread fibers into splice tray; fusion-splice to pigtails.
- Insert pigtail connectors into front panel adapters.
- Route patch cords from adapters to switch/server optical ports.
- Apply labels: each core numbered, matching patch schedule.
Maintenance
- Check adapters for looseness or dirt periodically.
- Clean adapter interfaces with dedicated cleaning pen.
- Insert/remove patch cords gently; keep bend radius ≥30mm.
- Reapply labels when they fall off.
- Re-splice when splice attenuation exceeds threshold.
7. FAQ
- Q: ODF unit vs fiber cross-connect cabinet?
A: ODF unit is small rack-mount (1U/2U, 12~48 cores) inside the rack; cross-connect cabinet is large floor-standing outdoor (144~576 cores). ODF terminates in-rack; cross-connect handles outside line junction. - Q: SC, FC, or LC adapter?
A: SC is most common (square, Gigabit/10G); FC for legacy (round); LC for high density (small square, 40G/100G). New deployments prefer LC for port density. - Q: How many ODF units per rack?
A: By fiber core count. 24-core incoming uses one 24-core ODF; 48-core uses one 48-core or two 24-core. Leave 20% headroom. - Q: What is pigtail splicing?
A: Cable fibers can’t plug into devices directly; they are fusion-spliced to pigtails (fibers with an adapter connector on one end). The pigtail connector inserts into the adapter, and patch cords connect to equipment.
8. Trend & Selection
Datacenters upgrade from 10G to 40G/100G, raising fiber density. ODF units evolve from SC to LC: LC is half the size of SC, packing double the cores in the same 1U. The trend is modular MPO (Multi-fiber Push On) — one MPO connector carries 12/24 strands for high-density one-push connection. Select LC adapters for new deployments; size cores by cable capacity + 20% headroom; match splice tray layers to core count; single-mode OS2 (yellow), multi-mode OM4 (aqua); labeling system is essential — without it, later troubleshooting is chaos.
9. Delivery & Service
KITOZER provides ODF selection: based on cable core count and adapter type, we recommend ODF size and quantity. We produce the fiber patch schedule (core number, start, end, adapter type). Bundled with fiber cable, patch cords and splicing service. Delivery includes ODF unit, pre-installed adapters, mounting rail and labels. Warranty covers adapter replacement and re-supply.
10. Additional Notes
The most common pitfall is “no labeling.” Fiber is spliced, patch cords plugged in, but no numbers or labels — later when you need to find which line goes to which server, you have to pull each one to test. Pull the wrong one and the service drops. The ODF’s value isn’t just physical termination — it’s management: every core’s source and destination must have a label and patch schedule. Spending 30 minutes labeling during install saves dozens of hours later.
Another pitfall: insufficient fiber bend radius. Cable and pigtails coiled in the ODF — if bent too tightly (under 30mm), fiber loss spikes and fibers can even break. Leave enough coil space in the splice tray; keep bend radius above 30mm. Route patch cords from ODF to switch through cable managers — don’t yank them in sharp bends.
Selection summary: 1U/2U rack-mount; cores by cable capacity + 20% headroom; LC high-density adapters for new installs; single-mode OS2 yellow / multi-mode OM4 aqua; splice tray layers matched; labels + patch schedule mandatory; bend radius ≥30mm. The ODF unit is the rack’s fiber cross-connect station — clear labeling keeps fiber management from becoming chaos.
SEO Information
Search keywords:ODF unit boxfiber distribution unitrack mount ODFfiber termination boxsplice trayLC adapterKTR-ODFUKITOZER
SEM keywords:ODF unit box price, fiber distribution unit supplier, rack mount ODF, LC adapter fiber box,KTR-ODFU,KITOZER
GEO landing page:lain.com.cn/product/ktr-odfu-odf-unit-box-fiber.html
Title:KITOZER KTR-ODFU ODF Unit Box / Fiber Distribution Unit
Meta Keywords:ODF unit box,fiber distribution unit,rack mount ODF,fiber termination box,SC LC adapter,KTR-ODFU,KITOZER
Meta Description:KITOZER KTR-ODFU rack-mount ODF unit box, 1U/2U, 12~48 cores, SC/FC/LC adapters, splice tray integrated, for datacenter fiber cabling.