The KITOZER 10kVA online double-conversion UPS with three-phase input and single-phase output is a workhorse for small and medium server rooms, banking branches, government service halls, and industrial control rooms where a three-phase commercial feed is available but the critical load is single-phase. The topology fully isolates the load from mains disturbances: a diode-rectifier plus PFC stage converts utility AC to DC, the inverter regenerates a clean 230V sine wave, and the battery bus bridges any gap between the two. With zero transfer time and low output voltage distortion, this UPS protects servers, storage, and network gear from even the most severe grid events. The 6-inch color touchscreen presents a single-pane view of input, output, battery, and load, and event logs with timestamps support post-incident analysis for compliance reviews.
Technical Specifications
Rated 10kVA / 9kW, power factor 0.9. Input three-phase 380 or 400VAC, range 304 to 478VAC, power factor 0.99. Output single-phase 220 or 230VAC, regulation +/-1 percent, THDi less than 2 percent for linear loads and less than 4 percent for nonlinear loads. Efficiency 95 percent. Internal VRLA batteries provide 10 minutes at full load; external battery cabinets extend runtime to one or more hours. 6-inch color touchscreen shows input, output, battery, and load data in real time. Parallel capability up to 4 units for N plus 1 redundancy or capacity expansion. Communication includes RS485, Modbus, USB, and optional SNMP or dry-contact card. Dimensions 600 x 800 x 1400 millimeters, weight 220 kilograms. CE and IEC 62040 certified. Overload 110 percent for 10 minutes, 125 percent for 1 minute. Audible alarm 55 dB at 1 meter. Operating temperature 0 to 40 degrees Celsius.
Application Scenarios
Common installations include 20 to 40 rack server rooms at corporate branch offices, retail chain data closets, medical imaging and laboratory equipment, broadcast transmission stations, and industrial SCADA control rooms. The three-phase input balances load across the building distribution while the single-phase output matches standard server PDU and rack power requirements, eliminating the need for an isolation or balancing transformer. It is also used in bank branch safe rooms, government agency service counters, university departmental server closets, and small data colocation cages. The unit is especially popular in regions where three-phase power is delivered to commercial tenants but the IT load is naturally single-phase.
Advantages and Features
The wide three-phase input window tolerates voltage dips down to 304VAC without switching to battery, conserving battery energy for true outages. Input power factor 0.99 minimizes upstream current and reduces transformer and generator oversizing. Output isolation transformer option ensures zero neutral-to-ground voltage and blocks common-mode noise for ultra-sensitive medical and audio loads. Reduced footprint compared to traditional 10kVA industrial units saves valuable server-room floor space. The color touchscreen supports multi-language menus and event logging with timestamp for compliance audits. A built-in maintenance bypass allows the entire UPS to be isolated for service while the load remains on utility power, and parallel capability lets operators add a second unit later for N plus 1 redundancy without replacing the first.
Installation and Maintenance Recommendations
Mount the UPS on a level floor capable of supporting at least 300 kilograms including external battery cabinet. Provide dedicated upstream breakers rated at 32 to 40A three-phase input and 50A single-phase output. Keep ambient temperature at 20 to 25 degrees Celsius and humidity below 80 percent non-condensing. Route battery cables away from signal cables to minimize noise interference. Conduct quarterly inspection of cooling fans, capacitor bulge, and terminal torque. Replace batteries every 4 to 5 years and keep spare fuse boards on site. Use KITOZER-trained service engineers for first-year commissioning to validate protection settings and load distribution. Keep at least 1 meter clearance in front and 0.8 meter at the rear for service access. Record the first full-load battery discharge test in the maintenance log and repeat it annually. Verify the generator can handle the 10kVA non-linear load with at least 15kVA of rated generator capacity.
Delivery and Warranty
The unit ships with a 7-inch touchscreen keypad, power cables, documentation CD, and mounting brackets. Standard lead time is 5 to 7 working days, and container shipments to overseas destinations take 25 to 35 days by sea. KITOZER provides a 3-year warranty on the UPS electronics and a 2-year warranty on batteries, with optional extended coverage up to 5 years. Factory engineers are available for remote commissioning guidance, and on-site commissioning can be arranged on request for larger deployments. Spare parts such as fan modules, control boards, and contactors are held in regional warehouses to support fast replacement.
Compatibility
The UPS works seamlessly with most server, storage, and network equipment from major vendors, and the monitoring software supports Windows, Linux, and macOS shutdown agents. The wide-input PFC stage is compatible with most standby and prime-power diesel generators rated at 15kVA or above. Optional SNMP card integrates with popular DCIM platforms, and the dry-contact card connects to building management systems for alarm monitoring. English technical documentation and datasheets are available for download on request.
Price
From $3,850/pc. Contact +86 13922289957 for external battery cabinet runtime packages and on-site commissioning options.