KITOZER
KITOZER

KITOZER Open Frame Diesel Generator 100kW For Factory Backup

Product Overview

The KITOZER 100kW open frame diesel generator is a mid-range standby and prime power unit built for small factories, construction sites, and commercial buildings that need around 100kW of three-phase power during grid interruptions. It pairs a six-cylinder turbocharged diesel engine with a Stamford-class brushless alternator, delivering 100kW prime and 110kW standby output. The open skid format keeps upfront investment lower than enclosed canopy units and allows direct access to the cooling system, fuel circuit, electrical cubicle, and exhaust manifold during preventive maintenance. KITOZER standardizes a deep-sea DSE controller, base tank, coolant heater, battery charger, and anti-vibration mounts, so the package arrives ready for cabling into the customer switchboard.

Technical Specifications

Continuous rating is 100kW at 0.8 power factor, standby rating 110kW. The engine is a six-cylinder in-line, water-cooled, turbocharged direct-injection diesel displacing around 6.5 liters, governed at 1500rpm for 50Hz or 1800rpm for 60Hz. Alternator is a brushless self-excited machine with AVR, class H insulation, IP23, and transient voltage recovery within 1.5 seconds for a 100 percent load step. Fuel consumption at 75 percent load is about 22 liters per hour; base tank provides around 6 hours of running. The control panel offers 3-phase voltage and current, frequency, kW, kVA, kWh, oil pressure, coolant temperature, fuel level, and run hours, plus engine protection shutdowns and Modbus RS485. Noise at 7 meters open frame is 98 to 105 dBA. Skid weight is roughly 2600kg and dimensions are 2800 by 1100 by 1500 millimeters.

Applications

This 100kW unit is sized for small manufacturing plants running production lines, compressed air stations, refrigeration racks, and office loads during utility outages. Construction contractors use it as the main power source for site offices, tower cranes, concrete batch plants, and temporary lighting. Shopping centers and mid-rise office buildings install it as a standby genset feeding the fire pump, elevators, emergency lighting, and critical HVAC. Because the open frame allows easy access, it is also favored by rental fleets that need fast turnaround between jobs and quick diagnosis of faults on site.

Advantages and Features

KITOZER engineers the 100kW open frame package for long service intervals and easy parts replacement. The engine features a replaceable wet cylinder liner, spin-on full-flow oil filter, dual fuel filters with water separator, and an air cleaner with safety element. The alternator uses a brushless design so scheduled service avoids commutator and brush inspection. Standard protections include overspeed shutdown, low oil pressure, high coolant temperature, overcurrent, short circuit, and emergency stop. A 24V electric starter, float battery charger, and engine coolant jacket heater are included. The controller accepts remote start contacts and optional Ethernet or GSM monitoring modules. Customers can choose tropical radiator, heavy-duty air cleaner, Arctic package with block heater and battery warmer, or dual frequency winding for export flexibility.

Installation and Maintenance Recommendations

Place the genset on a reinforced concrete foundation at least 200 millimeters thick, anchor the skid through the anti-vibration mounts, and keep clearance of 1 meter on both sides and 1.5 meters above for exhaust and radiator service. Exhaust piping must use flexible bellows to isolate engine movement, and the final silencer should be sized for backpressure below 6.7kPa. Install a separate fuel day tank if running beyond the base tank capacity, and route return fuel through a leak detection tray. Size the upstream ATS to 200A three phase and set the transfer delay to allow the generator to stabilize before closing the load contactor. Maintenance intervals: engine oil and filter every 250 hours, fuel filter every 500 hours, air filter service indicator checked weekly, coolant test every 6 months, valve lash every 2000 hours, and battery load test every 6 months. Exercise the set under 50 percent load monthly and verify protection trip functions quarterly.

Typical Customer Configuration

A typical KITOZER package for the 100kW unit includes a 200A floor-standing ATS, a 1000L day tank, an industrial exhaust silencer, and a GSM remote monitoring module. The ATS handles automatic transfer between utility and generator, the day tank supports overnight running, and the monitoring module provides real-time data and SMS alarms. This configuration is commonly specified by light factories, construction contractors, and rental fleet operators who need reliable unattended standby power with remote visibility.

Quality Assurance and Delivery

Every 100kW open frame generator undergoes a full load-bank test at KITOZER factory, covering no-load, 50 percent, 75 percent, and 100 percent load steps. Engineers record voltage, frequency, oil pressure, coolant temperature, exhaust temperature, and fuel consumption, and confirm all protection shutdowns trigger correctly. The unit is then painted, wrapped in anti-rust film, and loaded into a waxed steel export frame. Delivery scope includes the generator set, 24V battery, control manual, electrical schematic, spare oil and fuel filter kit, and 12 months of warranty. KITOZER can bundle wall or floor ATS, external day tank, industrial silencer, and GSM remote monitoring as a single package. CE documentation, packing list, and export carton labeling are provided for international customers.

Price

From $14,900 per set ex works Guangzhou. Contact KITOZER for ATS, sound canopy, and remote monitoring options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top