1. System Introduction
1.1 Product Overview
The KITOZER ordinary network cabinet is a standardized equipment storage and management solution specially designed for modern computer rooms, data centers and network communication environments. Complying with international standards such as EIA-310-D and IEC 60297, it adopts a 19-inch standard rack design to provide a safe and reliable physical operating environment for network devices including routers, switches, firewalls and patch panels. More than a simple “storage container” for equipment, this solution is an integrated management platform integrating physical protection, heat dissipation management, cable sorting and safety monitoring, which can significantly improve the stability, security and operation and maintenance efficiency of network infrastructure.
1.2 Core Values
- Standardized Deployment: Unified 19-inch installation specifications are compatible with all mainstream network devices, reducing the difficulty of equipment selection and integration.
- All-round Protection: It provides multiple protections including dust prevention, moisture prevention, electromagnetic interference resistance and anti-theft, extending the service life of equipment.
- Efficient Heat Dissipation Management: Optimized airflow design ensures equipment operates within the optimal temperature range of 18-27℃ and reduces hardware failure rates.
- Convenient Operation and Maintenance: Modular design supports rapid installation, expansion and maintenance, improving IT management efficiency.
- Ordered Cable Management: Professional cable sorting system reduces signal interference, lowers fault troubleshooting difficulty and optimizes network performance.

2. System Composition
The KITOZER ordinary network cabinet system adopts a modular design, consisting of the following core components. All modules work collaboratively to form a complete and efficient network equipment operation and maintenance support system.
| Module Category | Core Components | Function Description |
| Basic Structure Module | Cabinet frame, front & rear doors, top & bottom panels, side panels, mounting columns | Provide basic equipment installation support and physical protection, with a bearing capacity of 800-1200kg to ensure overall structural stability of the cabinet. |
| Installation & Management Module | Mounting guide rails, fixed shelves, sliding keyboard trays, cable management racks, blanking panels | Realize fixed positioning of equipment, orderly sorting of internal cables and optimized internal airflow distribution to avoid airflow short circuit. |
| Heat Dissipation & Ventilation Module | Mesh doors (opening rate ≥70%), cooling fans, ventilation holes | Form an efficient heat dissipation channel with cold air entering from the front and hot air discharging from the rear to ensure long-term stable operation of network equipment. |
| Power Distribution Management Module | Rack-mounted PDU (Power Distribution Unit), power sockets, cable troughs | Provide safe and stable power distribution, with overload protection and optional remote monitoring functions to guarantee reliable power supply for equipment. |
| Safety Protection Module | Door lock system, grounding device, EMI shielding layer | Prevent unauthorized access, eliminate static electricity and electromagnetic interference, and fully protect equipment operation safety. |
| Mobile Support Module | Casters, fixed support feet, cabinet combination connectors | Support flexible movement and precise positioning of the cabinet, and realize multi-cabinet parallel deployment and expansion to improve overall deployment density. |
| Optional Expansion Module | Intelligent monitoring unit, temperature & humidity sensor, access control system | Realize real-time monitoring and remote management of the cabinet micro-environment, improving intelligent operation and maintenance level. |

3. System Classification
3.1 Classification by Installation Method
| Classification | Model Example | Dimension Range | Application Scenarios | Features |
| Floor-standing Network Cabinet | KT-NW6042 | 600W×800D×2000H (42U) | Enterprise computer rooms, data centers, IDC rooms | Large capacity (22-42U), load-bearing 800-1200kg, suitable for large-scale network deployment |
| Wall-mounted Network Cabinet | KT-NW6012 | 600W×600D×600H (12U) | Weak current rooms, offices, small branch offices | Space-saving, flexible installation, suitable for equipment deployment below 12U |
| Open Rack | KT-NW8032 | 800W×1000D×1600H (32U) | Test environments, temporary deployment, high-density equipment scenarios | No side panel design, excellent heat dissipation, convenient for equipment maintenance |
3.2 Classification by Functional Features
| Classification | Core Features | Application Scenarios |
| Standard Type | Basic configuration, high cost performance, meeting conventional network deployment needs | Small and medium-sized enterprise network rooms, general network deployment scenarios |
| Enhanced Type | Thickened plates (1.2-1.5mm), high load-bearing (≥1000kg), enhanced heat dissipation performance | Core computer rooms, high-density equipment deployment, long-term continuous operation scenarios |
| Intelligent Type | Integrated temperature and humidity monitoring, remote power control, access control management | Unattended computer rooms, distributed deployment environments, scenarios requiring high operation and maintenance efficiency |
| Silent Type | Special sound insulation materials, low-noise fans, optimized noise reduction design | Computer rooms near office areas, medical environments and other noise-sensitive scenarios |
3.3 Classification by Size Specification
- Width: Two mainstream specifications of 600mm (standard) and 800mm (cable management optimized type)
- Depth: 600mm (adapts to conventional network equipment), 800mm (compatible with servers), 1000mm (high-density deployment)
- Height: 12U (535mm), 22U (1000mm), 32U (1450mm), 42U (2000mm), covering deployment needs of different scales

4. System Configuration List (Brand: KITOZER)
4.1 Standard Configuration List (Floor-standing 42U Network Cabinet)
| No. | Product Name | Model | Specification Parameters | Quantity | Remarks |
| 1 | Network Cabinet Main Body | KT-NW6042 | 600W×800D×2000H (42U), SPCC cold-rolled steel plate, 1.2-1.5mm thickness | 1 Set | Static load ≥1000kg |
| 2 | Tempered Glass Front Door | KT-DOOR-GLASS | Mesh + tempered glass combination, opening rate ≥70%, with door lock | 1 Pc | Balance of safety protection and visualization |
| 3 | Mesh Rear Door | KT-DOOR-MESH | Full steel mesh, opening rate ≥75%, double-door design | 1 Pair | Optimize heat dissipation and facilitate maintenance |
| 4 | Mounting Columns | KT-RAIL-19 | 19-inch standard, square hole strip design, adjustable spacing | 4 Pcs | Compatible with all standard rack-mounted equipment |
| 5 | Fixed Shelves | KT-SHELF-1200 | 1.2mm cold-rolled steel plate, load capacity ≥50kg | 2 Pcs | Place non-rack-mounted equipment |
| 6 | Cable Management Rack | KT-CM-1U | 1U height, metal material, ring cable management ring | 4 Pcs | Horizontal cable management to reduce signal interference |
| 7 | Blanking Panels | KT-BLANK-1U | 1U height, metal material | 10 Pcs | Optimize airflow and improve heat dissipation efficiency |
| 8 | Rack-mounted PDU | KT-PDU-16A | 16A input, 10-bit 10A output, with overload protection | 1 Pc | Safe power distribution |
| 9 | Casters & Support Feet | KT-CASTER-4 | Single load ≥300kg, with brake function | 4 Sets | Dual functions of movement and fixing |
| 10 | Cabinet Combination Connectors | KT-JOINT-SET | Special connecting kit for multi-cabinet deployment | 2 Sets | Improve deployment density |
| 11 | Grounding Copper Bar | KT-GROUND-BAR | 50×5mm copper bar, with grounding terminals | 1 Set | Eliminate static interference to ensure equipment safety |
4.2 Optional Accessories List
| No. | Product Name | Model | Function Description |
| 1 | Intelligent Monitoring Unit | KT-MONITOR-100 | Integrated temperature and humidity monitoring, smoke detection and access control management functions |
| 2 | Cooling Fan Kit | KT-FAN-4 | 4×60W fans, supporting automatic temperature control to enhance heat dissipation |
| 3 | Sliding Keyboard Tray | KT-KB-TABLE | Retractable design, supporting 17-inch keyboard and mouse placement |
| 4 | Guide Rail Kit | KT-RACK-RAIL | Special server guide rails, supporting pull-out installation and maintenance |
| 5 | Vertical Cable Manager | KT-CM-VERTICAL | Vertical cable trough with capacity for more than 200 network cables, optimizing internal cable layout |

5. System Schematic Diagram
5.1 Cabinet Physical Structure Schematic
| Plain Text ┌─────────────────────────────────────────┐ │ Top Panel (with vents) │ │ ┌─────────────┐ ┌─────────────┐ │ │ │ Cooling Fan │ │ Cooling Fan │ │ │ └─────────────┘ └─────────────┘ │ ├─────────────────────────────────────────┤ │ ┌─────────────────────────────────┐ │ │ │ Tempered Glass Front Door │ │ │ │ (Opening Rate≥70%, Locked, Visible) │ │ └─────────────────────────────────┘ │ │ ┌─────────────────────────────────┐ │ │ │ │ │ │ │ ┌─────────┐ ┌─────────┐ │ │ │ │ │ Switch │ │ Router │ │ │ │ │ └─────────┘ └─────────┘ │ │ │ │ ┌─────────┐ ┌─────────┐ │ │ │ │ │ Patch │ │ Firewall│ │ │ │ │ └─────────┘ └─────────┘ │ │ │ │ │ │ │ │ ┌─────────────────────────┐ │ │ │ │ │ │ │ │ │ │ │ Cable Management System │ │ │ │ │ │ (Horizontal + Vertical) │ │ │ │ │ │ │ │ │ │ │ └─────────────────────────┘ │ │ │ └─────────────────────────────────┘ │ │ ┌─────────────────────────────────┐ │ │ │ Double Mesh Rear Door │ │ │ │ (Opening Rate≥75%, Double Door) │ │ │ └─────────────────────────────────┘ │ ├─────────────────────────────────────────┤ │ Bottom Panel (with cable inlet) │ │ ┌─────────────┐ ┌─────────────┐ │ │ │ Braked Caster │ │ Fixed Support Foot │ │ │ └─────────────┘ └─────────────┘ │ └─────────────────────────────────────────┘ |
5.2 Heat Dissipation Airflow Schematic
The KITOZER network cabinet adopts the classic “front air intake and rear air exhaust” heat dissipation mode to ensure efficient internal air circulation:
- Cold Air Intake: Cold air enters the cabinet through the front door mesh (opening rate ≥70%).
- Equipment Heat Absorption: Cold air flows through operating equipment and absorbs heat to increase temperature.
- Hot Air Exhaust: Heated hot air is discharged out of the cabinet through the rear door mesh (opening rate ≥75%).
- Auxiliary Heat Dissipation: Optional top fan kit enhances hot air exhaust efficiency and forms an auxiliary “bottom-in top-out” airflow.
- Airflow Optimization: Blanking panels fill empty U positions to prevent airflow short circuit and ensure cold air flows through all heat-generating equipment.
5.3 Power Distribution System Schematic
| Plain Text Mains Input → Main Circuit Breaker → Rack-mounted PDU → Power Socket → Network Equipment ↓ ↓ ↓ Lightning Protection Overload Protection Optional Remote Monitoring ↓ Grounding System (Eliminate Static Interference) |

6. Product Technical Parameters
6.1 Basic Structural Parameters
| Parameter Item | Technical Specification | Remarks |
| Material | High-quality SPCC cold-rolled steel plate, 1.5mm thick columns, 1.2mm thick other panels | Comply with GB/T 708-2019 standard |
| Surface Treatment | Degreasing, pickling, phosphating, electrostatic powder spraying (black/gray) | Corrosion resistant, RoHS environmental compliant |
| Installation Standard | 19-inch standard rack, compliant with EIA-310-D, IEC 60297 | Compatible with all mainstream network equipment |
| Load-bearing Capacity | Static load ≥1000kg, dynamic load ≥600kg | Ensure safe equipment installation |
| Protection Level | Basic IP20, optional IP30 enhanced protection | Dust-proof, prevent finger contact with live parts |
| Color | Black (RAL9005), Gray (RAL7035), customizable | Adapt to computer room environmental aesthetics |
6.2 Dimensional Specification Parameters
| Model | Width (W) | Depth (D) | Height (H) | Capacity (U) | Application Scenarios |
| KT-NW6012 | 600mm | 600mm | 600mm | 12U | Wall-mounted, small-scale network deployment |
| KT-NW6022 | 600mm | 800mm | 1000mm | 22U | Floor-standing, small and medium enterprise network |
| KT-NW6032 | 600mm | 800mm | 1450mm | 32U | Floor-standing, medium-sized network computer room |
| KT-NW6042 | 600mm | 800mm | 2000mm | 42U | Floor-standing, large data center |
| KT-NW8042 | 800mm | 1000mm | 2000mm | 42U | Floor-standing, high-density network deployment |
6.3 Heat Dissipation and Ventilation Parameters
| Parameter Item | Technical Specification | Performance Index |
| Front Door Opening Rate | Mesh + tempered glass combination design | ≥70%, ensuring sufficient cold air intake |
| Rear Door Opening Rate | Full steel mesh double-door design | ≥75%, accelerating hot air discharge |
| Optional Fan Parameters | 4×60W axial fans, 2800rpm rotating speed | Air volume ≥120CFM per fan, noise ≤45dB |
| Operating Temperature | Indoor adaptive temperature range | -10℃~+40℃ |
| Relative Humidity | Non-condensing environment requirement | 10%~85%RH |
6.4 Power Distribution System Parameters
| Parameter Item | Technical Specification | Safety Standard |
| PDU Input | 16A/32A, 220V/380V | Compliant with GB 1002-2008 |
| Output Socket | 10/16-bit, 10A/16A, compatible with IEC C13/C19 | National standard socket specification |
| Protection Functions | Overload, short circuit and optional lightning protection | Compliant with GB 16895.21-2011 |
| Monitoring Function | Optional remote monitoring of current and voltage | Real-time power consumption monitoring |

7. Application Scope
7.1 Enterprise-level Applications
- Small and Medium-sized Enterprise Computer Rooms: Provide network support for office networks, financial systems, OA systems and other core business systems.
- Large Enterprise Branches: Realize standardized deployment, reduce IT management complexity and improve network stability.
- R&D and Test Environments: Open or semi-open cabinets facilitate equipment commissioning, testing and daily maintenance.
7.2 Data Center and IDC Applications
- Edge Data Centers: Support modular deployment and adapt to distributed IT architecture requirements.
- Hosting Computer Rooms: Standardized cabinet design meets the coexistence needs of multi-tenant equipment.
- Cloud Computing Data Centers: High-density network cabinets support large-scale deployment of servers and network equipment.