KITOZER
KITOZER

KITOZER Ordinary Network Cabinet Solution

1. System Introduction

1.1 Product Overview

The KITOZER ordinary network cabinet is a standardized equipment storage and management solution specially designed for modern computer rooms, data centers and network communication environments. Complying with international standards such as EIA-310-D and IEC 60297, it adopts a 19-inch standard rack design to provide a safe and reliable physical operating environment for network devices including routers, switches, firewalls and patch panels. More than a simple “storage container” for equipment, this solution is an integrated management platform integrating physical protection, heat dissipation management, cable sorting and safety monitoring, which can significantly improve the stability, security and operation and maintenance efficiency of network infrastructure.

1.2 Core Values

  • Standardized Deployment: Unified 19-inch installation specifications are compatible with all mainstream network devices, reducing the difficulty of equipment selection and integration.
  • All-round Protection: It provides multiple protections including dust prevention, moisture prevention, electromagnetic interference resistance and anti-theft, extending the service life of equipment.
  • Efficient Heat Dissipation Management: Optimized airflow design ensures equipment operates within the optimal temperature range of 18-27℃ and reduces hardware failure rates.
  • Convenient Operation and Maintenance: Modular design supports rapid installation, expansion and maintenance, improving IT management efficiency.
  • Ordered Cable Management: Professional cable sorting system reduces signal interference, lowers fault troubleshooting difficulty and optimizes network performance.
standard network rack solution (8)

2. System Composition

The KITOZER ordinary network cabinet system adopts a modular design, consisting of the following core components. All modules work collaboratively to form a complete and efficient network equipment operation and maintenance support system.

Module CategoryCore ComponentsFunction Description
Basic Structure ModuleCabinet frame, front & rear doors, top & bottom panels, side panels, mounting columnsProvide basic equipment installation support and physical protection, with a bearing capacity of 800-1200kg to ensure overall structural stability of the cabinet.
Installation & Management ModuleMounting guide rails, fixed shelves, sliding keyboard trays, cable management racks, blanking panelsRealize fixed positioning of equipment, orderly sorting of internal cables and optimized internal airflow distribution to avoid airflow short circuit.
Heat Dissipation & Ventilation ModuleMesh doors (opening rate ≥70%), cooling fans, ventilation holesForm an efficient heat dissipation channel with cold air entering from the front and hot air discharging from the rear to ensure long-term stable operation of network equipment.
Power Distribution Management ModuleRack-mounted PDU (Power Distribution Unit), power sockets, cable troughsProvide safe and stable power distribution, with overload protection and optional remote monitoring functions to guarantee reliable power supply for equipment.
Safety Protection ModuleDoor lock system, grounding device, EMI shielding layerPrevent unauthorized access, eliminate static electricity and electromagnetic interference, and fully protect equipment operation safety.
Mobile Support ModuleCasters, fixed support feet, cabinet combination connectorsSupport flexible movement and precise positioning of the cabinet, and realize multi-cabinet parallel deployment and expansion to improve overall deployment density.
Optional Expansion ModuleIntelligent monitoring unit, temperature & humidity sensor, access control systemRealize real-time monitoring and remote management of the cabinet micro-environment, improving intelligent operation and maintenance level.
standard network rack solution (7)

3. System Classification

3.1 Classification by Installation Method

ClassificationModel ExampleDimension RangeApplication ScenariosFeatures
Floor-standing Network CabinetKT-NW6042600W×800D×2000H (42U)Enterprise computer rooms, data centers, IDC roomsLarge capacity (22-42U), load-bearing 800-1200kg, suitable for large-scale network deployment
Wall-mounted Network CabinetKT-NW6012600W×600D×600H (12U)Weak current rooms, offices, small branch officesSpace-saving, flexible installation, suitable for equipment deployment below 12U
Open RackKT-NW8032800W×1000D×1600H (32U)Test environments, temporary deployment, high-density equipment scenariosNo side panel design, excellent heat dissipation, convenient for equipment maintenance

3.2 Classification by Functional Features

ClassificationCore FeaturesApplication Scenarios
Standard TypeBasic configuration, high cost performance, meeting conventional network deployment needsSmall and medium-sized enterprise network rooms, general network deployment scenarios
Enhanced TypeThickened plates (1.2-1.5mm), high load-bearing (≥1000kg), enhanced heat dissipation performanceCore computer rooms, high-density equipment deployment, long-term continuous operation scenarios
Intelligent TypeIntegrated temperature and humidity monitoring, remote power control, access control managementUnattended computer rooms, distributed deployment environments, scenarios requiring high operation and maintenance efficiency
Silent TypeSpecial sound insulation materials, low-noise fans, optimized noise reduction designComputer rooms near office areas, medical environments and other noise-sensitive scenarios

3.3 Classification by Size Specification

  • Width: Two mainstream specifications of 600mm (standard) and 800mm (cable management optimized type)
  • Depth: 600mm (adapts to conventional network equipment), 800mm (compatible with servers), 1000mm (high-density deployment)
  • Height: 12U (535mm), 22U (1000mm), 32U (1450mm), 42U (2000mm), covering deployment needs of different scales
standard network rack solution (6)

4. System Configuration List (Brand: KITOZER)

4.1 Standard Configuration List (Floor-standing 42U Network Cabinet)

No.Product NameModelSpecification ParametersQuantityRemarks
1Network Cabinet Main BodyKT-NW6042600W×800D×2000H (42U), SPCC cold-rolled steel plate, 1.2-1.5mm thickness1 SetStatic load ≥1000kg
2Tempered Glass Front DoorKT-DOOR-GLASSMesh + tempered glass combination, opening rate ≥70%, with door lock1 PcBalance of safety protection and visualization
3Mesh Rear DoorKT-DOOR-MESHFull steel mesh, opening rate ≥75%, double-door design1 PairOptimize heat dissipation and facilitate maintenance
4Mounting ColumnsKT-RAIL-1919-inch standard, square hole strip design, adjustable spacing4 PcsCompatible with all standard rack-mounted equipment
5Fixed ShelvesKT-SHELF-12001.2mm cold-rolled steel plate, load capacity ≥50kg2 PcsPlace non-rack-mounted equipment
6Cable Management RackKT-CM-1U1U height, metal material, ring cable management ring4 PcsHorizontal cable management to reduce signal interference
7Blanking PanelsKT-BLANK-1U1U height, metal material10 PcsOptimize airflow and improve heat dissipation efficiency
8Rack-mounted PDUKT-PDU-16A16A input, 10-bit 10A output, with overload protection1 PcSafe power distribution
9Casters & Support FeetKT-CASTER-4Single load ≥300kg, with brake function4 SetsDual functions of movement and fixing
10Cabinet Combination ConnectorsKT-JOINT-SETSpecial connecting kit for multi-cabinet deployment2 SetsImprove deployment density
11Grounding Copper BarKT-GROUND-BAR50×5mm copper bar, with grounding terminals1 SetEliminate static interference to ensure equipment safety

4.2 Optional Accessories List

No.Product NameModelFunction Description
1Intelligent Monitoring UnitKT-MONITOR-100Integrated temperature and humidity monitoring, smoke detection and access control management functions
2Cooling Fan KitKT-FAN-44×60W fans, supporting automatic temperature control to enhance heat dissipation
3Sliding Keyboard TrayKT-KB-TABLERetractable design, supporting 17-inch keyboard and mouse placement
4Guide Rail KitKT-RACK-RAILSpecial server guide rails, supporting pull-out installation and maintenance
5Vertical Cable ManagerKT-CM-VERTICALVertical cable trough with capacity for more than 200 network cables, optimizing internal cable layout
standard network rack solution (5)

5. System Schematic Diagram

5.1 Cabinet Physical Structure Schematic

Plain Text
┌─────────────────────────────────────────┐
│              Top Panel (with vents)             │
│  ┌─────────────┐  ┌─────────────┐      │
│  │ Cooling Fan │  │ Cooling Fan │      │
│  └─────────────┘  └─────────────┘      │
├─────────────────────────────────────────┤
│  ┌─────────────────────────────────┐   │
│  │ Tempered Glass Front Door       │   │
│  │ (Opening Rate≥70%, Locked, Visible) │
│  └─────────────────────────────────┘   │
│  ┌─────────────────────────────────┐   │
│  │                                 │   │
│  │  ┌─────────┐  ┌─────────┐      │   │
│  │  │ Switch  │  │ Router  │      │   │
│  │  └─────────┘  └─────────┘      │   │
│  │  ┌─────────┐  ┌─────────┐      │   │
│  │  │ Patch   │  │ Firewall│      │   │
│  │  └─────────┘  └─────────┘      │   │
│  │                                 │   │
│  │  ┌─────────────────────────┐    │   │
│  │  │                         │    │   │
│  │  │   Cable Management System      │    │   │
│  │  │ (Horizontal + Vertical) │    │   │
│  │  │                         │    │   │
│  │  └─────────────────────────┘    │   │
│  └─────────────────────────────────┘   │
│  ┌─────────────────────────────────┐   │
│  │ Double Mesh Rear Door           │   │
│  │ (Opening Rate≥75%, Double Door) │   │
│  └─────────────────────────────────┘   │
├─────────────────────────────────────────┤
│          Bottom Panel (with cable inlet)        │
│  ┌─────────────┐  ┌─────────────┐      │
│  │ Braked Caster │  │ Fixed Support Foot │      │
│  └─────────────┘  └─────────────┘      │
└─────────────────────────────────────────┘

5.2 Heat Dissipation Airflow Schematic

The KITOZER network cabinet adopts the classic “front air intake and rear air exhaust” heat dissipation mode to ensure efficient internal air circulation:

  1. Cold Air Intake: Cold air enters the cabinet through the front door mesh (opening rate ≥70%).
  2. Equipment Heat Absorption: Cold air flows through operating equipment and absorbs heat to increase temperature.
  3. Hot Air Exhaust: Heated hot air is discharged out of the cabinet through the rear door mesh (opening rate ≥75%).
  4. Auxiliary Heat Dissipation: Optional top fan kit enhances hot air exhaust efficiency and forms an auxiliary “bottom-in top-out” airflow.
  5. Airflow Optimization: Blanking panels fill empty U positions to prevent airflow short circuit and ensure cold air flows through all heat-generating equipment.

5.3 Power Distribution System Schematic

Plain Text
Mains Input → Main Circuit Breaker → Rack-mounted PDU → Power Socket → Network Equipment
     ↓          ↓          ↓
  Lightning Protection  Overload Protection  Optional Remote Monitoring
     ↓
  Grounding System (Eliminate Static Interference)
standard network rack solution (4)

6. Product Technical Parameters

6.1 Basic Structural Parameters

Parameter ItemTechnical SpecificationRemarks
MaterialHigh-quality SPCC cold-rolled steel plate, 1.5mm thick columns, 1.2mm thick other panelsComply with GB/T 708-2019 standard
Surface TreatmentDegreasing, pickling, phosphating, electrostatic powder spraying (black/gray)Corrosion resistant, RoHS environmental compliant
Installation Standard19-inch standard rack, compliant with EIA-310-D, IEC 60297Compatible with all mainstream network equipment
Load-bearing CapacityStatic load ≥1000kg, dynamic load ≥600kgEnsure safe equipment installation
Protection LevelBasic IP20, optional IP30 enhanced protectionDust-proof, prevent finger contact with live parts
ColorBlack (RAL9005), Gray (RAL7035), customizableAdapt to computer room environmental aesthetics

6.2 Dimensional Specification Parameters

ModelWidth (W)Depth (D)Height (H)Capacity (U)Application Scenarios
KT-NW6012600mm600mm600mm12UWall-mounted, small-scale network deployment
KT-NW6022600mm800mm1000mm22UFloor-standing, small and medium enterprise network
KT-NW6032600mm800mm1450mm32UFloor-standing, medium-sized network computer room
KT-NW6042600mm800mm2000mm42UFloor-standing, large data center
KT-NW8042800mm1000mm2000mm42UFloor-standing, high-density network deployment

6.3 Heat Dissipation and Ventilation Parameters

Parameter ItemTechnical SpecificationPerformance Index
Front Door Opening RateMesh + tempered glass combination design≥70%, ensuring sufficient cold air intake
Rear Door Opening RateFull steel mesh double-door design≥75%, accelerating hot air discharge
Optional Fan Parameters4×60W axial fans, 2800rpm rotating speedAir volume ≥120CFM per fan, noise ≤45dB
Operating TemperatureIndoor adaptive temperature range-10℃~+40℃
Relative HumidityNon-condensing environment requirement10%~85%RH

6.4 Power Distribution System Parameters

Parameter ItemTechnical SpecificationSafety Standard
PDU Input16A/32A, 220V/380VCompliant with GB 1002-2008
Output Socket10/16-bit, 10A/16A, compatible with IEC C13/C19National standard socket specification
Protection FunctionsOverload, short circuit and optional lightning protectionCompliant with GB 16895.21-2011
Monitoring FunctionOptional remote monitoring of current and voltageReal-time power consumption monitoring
standard network rack solution (3)

7. Application Scope

7.1 Enterprise-level Applications

  • Small and Medium-sized Enterprise Computer Rooms: Provide network support for office networks, financial systems, OA systems and other core business systems.
  • Large Enterprise Branches: Realize standardized deployment, reduce IT management complexity and improve network stability.
  • R&D and Test Environments: Open or semi-open cabinets facilitate equipment commissioning, testing and daily maintenance.

7.2 Data Center and IDC Applications

  • Edge Data Centers: Support modular deployment and adapt to distributed IT architecture requirements.
  • Hosting Computer Rooms: Standardized cabinet design meets the coexistence needs of multi-tenant equipment.
  • Cloud Computing Data Centers: High-density network cabinets support large-scale deployment of servers and network equipment.

Shopping Cart