Table of Contents
Toggle1. System Overview
The outdoor energy storage container is a highly integrated, modular energy storage solution launched by KITOZER. Built on a standard container frame, it integrates core subsystems including energy storage batteries, BMS, PCS, EMS, temperature control, fire protection and power distribution into one unit. It features plug-and-play deployment, rapid installation, strong environmental adaptability and reliable safety. As a new energy storage carrier, it realizes electric energy storage, scheduling and stable output, applicable to multiple scenarios such as grid peak shaving and frequency regulation, new energy consumption, industrial & commercial peak-valley arbitrage, microgrid power supply and emergency backup power. It supports the realization of the “Dual Carbon” goals and the transformation and upgrading of the energy structure.
KITOZER outdoor energy storage containers strictly comply with domestic and international standards including ISO, IEC and GB. Adopting industrial anti-corrosion, waterproof and dustproof design with IP54/IP55 protection rating, they can operate stably under extreme temperatures ranging from -30℃ to 55℃. Customizable capacity (50kWh – 5MWh) and power (30kW – 2.5MW) are available, balancing standardized mass production and personalized demands. We also provide value-added services including OEM/ODM processing, technical confidentiality and spot direct delivery.
2. System Composition
The KITOZER outdoor energy storage container consists of seven coordinated subsystems: core energy storage unit, energy conversion unit, intelligent management & control unit, temperature control & heat dissipation unit, fire protection & security unit, power distribution auxiliary unit and cabinet structure unit, which jointly ensure safe and efficient system operation.
- Core Energy Storage Unit: Lithium iron phosphate battery modules/clusters (Grade A cells), battery racks and high-voltage combiner boxes, serving as the energy core for electric energy storage and release.
- Energy Conversion Unit: Bidirectional DC/AC power conversion system (PCS), isolation transformers and bypass switches, realizing bidirectional conversion between DC and AC power to match grid and load requirements.
- Intelligent Management & Control Unit: Battery Management System (BMS, including main BCMU and slave BMU), Energy Management System (EMS) and remote monitoring terminals. It monitors battery status in real time, optimizes charge-discharge strategies and enables remote operation & maintenance.
- Temperature Control & Heat Dissipation Unit: Air-cooled air conditioners/liquid cooling units, air ducts/liquid cooling pipelines and temperature sensors. It maintains cabin temperature at 25±2℃ and cell temperature difference ≤2℃ to extend battery service life.
- Fire Protection & Security Unit: HFC-227ea/aerosol fire extinguishing devices, smoke/temperature detectors, combustible gas sensors, emergency lighting and access control monitoring, delivering full-link fire early warning and fire suppression protection.
- Power Distribution Auxiliary Unit: AC/DC distribution cabinets, UPS, earthing systems and lightning protection devices, cable trays. It ensures safe and stable power distribution with overvoltage, overcurrent and short-circuit protection functions.
- Cabinet Structure Unit: Standard 20FT/40FT containers with C4/C5 anti-corrosion coating, sealed doors/windows and lifting structures. It boasts earthquake resistance, wind resistance, rainproof and moisture-proof performance for long-term outdoor deployment.
3. System Classification
3.1 Classification by Capacity & Power
- Small Energy Storage Container (Low Power & Small Capacity): 50kWh – 300kWh, 30kW – 100kW, air-cooled, 20FT cabinet. Applicable to industrial & commercial backup power, small microgrids and charging pile supporting facilities.
- Medium Energy Storage Container (Medium Power & Medium Capacity): 500kWh – 1.5MWh, 125kW – 500kW, air/liquid cooling optional, 20FT/40FT cabinet. Applicable to grid-side frequency regulation, new energy power station supporting and large industrial & commercial peak-valley arbitrage.
- Large Energy Storage Container (High Power & Large Capacity): 2MWh – 5MWh, 630kW – 2.5MW, liquid-cooled, 40FT cabinet. Applicable to utility-scale energy storage power stations, wind-solar-storage integrated projects and main power sources for grid peak shaving.
3.2 Classification by Cooling Method
- Air-cooled Energy Storage Container: Industrial air conditioner + air duct heat dissipation. Simple structure, low cost and easy maintenance, suitable for mild climates (-10℃ ~ 45℃). Mainstream option for small and medium-sized systems.
- Liquid-cooled Energy Storage Container: Ethylene glycol aqueous solution circulating heat dissipation. High heat dissipation efficiency, cell temperature difference ≤2℃, 30% lower energy consumption compared with air cooling. Suitable for high-temperature, frigid and high-humidity extreme environments, the preferred choice for medium and large systems.
3.3 Classification by Application Scenario
- Grid-side Energy Storage Container: High power and large capacity, supporting frequency regulation, peak shaving and voltage regulation with fast response speed (≤200ms) and high stability.
- User-side Energy Storage Container: Medium-low power and medium capacity, applicable to industrial & commercial peak-valley arbitrage, demand management, backup power and power quality governance.
- New Energy Supporting Energy Storage Container: Matched with photovoltaic/wind power stations to smooth output fluctuations, improve consumption capacity and guarantee grid-connected stability.
- Microgrid Energy Storage Container: Dual grid-connected/off-grid mode, suitable for power-free areas, isolated islands and remote mining areas, supplying power in coordination with photovoltaic, wind power and diesel generators.
- Mobile Energy Storage Container: Equipped with trailer/lifting structures for rapid relocation, applicable to emergency power supply, temporary construction power and event support.
3.4 Classification by Cabinet Specification
- 20FT Standard Energy Storage Container: Dimensions 6058mm×2438mm×2591mm, capacity 50kWh – 1.5MWh, power 30kW – 500kW. Flexible deployment and convenient transportation.
- 40FT Standard Energy Storage Container: Dimensions 12192mm×2438mm×2591mm, capacity 2MWh – 5MWh, power 630kW – 2.5MW. High capacity density for large-scale projects.
4. System Schematic Diagram
The KITOZER outdoor energy storage container system adopts a DC-side centralized convergence and AC-side centralized grid-connected/load-bearing architecture. Core circuit: Battery Cluster → High-voltage Combiner Box → PCS → Isolation Transformer → AC Distribution Cabinet → Grid/Load; Auxiliary circuit: BMS → EMS → Local/Remote Monitoring Terminal, Temperature Control System/Fire Protection System → EMS, realizing full-link control of energy flow, information flow and safety flow.
4.1 Core Working Principle
- Charging Mode: AC power from grid/photovoltaic/wind power is rectified into DC power by PCS, distributed to battery clusters via high-voltage combiner boxes. BMS monitors the whole charging process to ensure cell voltage, temperature and current stay within safe ranges.
- Discharging Mode: DC power released by battery clusters is collected through high-voltage combiner boxes, inverted into AC power by PCS, stabilized by isolation transformers and output to loads/grid via AC distribution cabinets.
- Intelligent Management & Control: BMS collects real-time cell voltage, temperature, SOC and SOH data and uploads to EMS. EMS optimizes charge-discharge power and timing based on grid dispatching instructions, load demand and electricity price strategies, supporting remote monitoring, fault alarms and parameter configuration.
- Safety Protection: Upon faults including overvoltage/undervoltage, overcurrent, short circuit, electric leakage, overtemperature, smoke and combustible gas, BMS/EMS immediately cuts off the circuit and activates fire extinguishing devices to guarantee system safety.
5. Full System Configuration List (KITOZER, Basic / Medium / Premium Three Grades)
5.1 Basic Version (20FT, 50kWh/30kW, Air-cooled)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-51.2V100Ah | Lithium iron phosphate, 51.2V, 100Ah, cycle life ≥5000 times, Grade A cells, operating temperature -20℃~60℃ | 10 | Set | KITOZER | Connected in series to form 512V battery cluster |
| 2 | Battery Rack | KITOZER-BR-20FT-10 Layer | Cold-rolled steel, anti-corrosion coating, load capacity ≥500kg/layer, compatible with 20FT cabinet | 1 | Set | KITOZER | Including insulation accessories and fixing bolts |
| 3 | High-voltage Combiner Box | KITOZER-HB-500V-10 Strings | DC500V, 10 input channels, 1 output channel, anti-reverse connection, overcurrent protection, insulation monitoring | 1 | Unit | KITOZER | IP54, wall-mounted |
| 4 | Power Conversion System (PCS) | KITOZER-PCS-30kW-500V | Bidirectional DC/AC, 30kW, DC400V~600V, AC380V±10%, THDi<5%, efficiency ≥95% | 1 | Unit | KITOZER | Air-cooled, dual grid-connected/off-grid mode |
| 5 | Isolation Transformer | KITOZER-TR-30kVA-380V | 30kVA, three-phase, 380V/380V, isolation voltage ≥2000V, efficiency ≥98% | 1 | Unit | KITOZER | Dry type, IP20 |
| 6 | Battery Management System (BMS) | KITOZER-BMS-500V | Main + slave control, supports 10 module strings, voltage accuracy ±0.5%, temperature accuracy ±1℃, SOC accuracy ±3%, overvoltage/undervoltage/overcurrent/overtemperature protection | 1 | Set | KITOZER | Including 1×BCMU, 10×BMU |
| 7 | Energy Management System (EMS) | KITOZER-EMS-30kW | Local monitoring + remote operation & maintenance, supports peak-valley arbitrage and backup power mode, Modbus/TCP communication, data storage ≥1 year | 1 | Set | KITOZER | Including touch screen and monitoring software |
| 8 | Air-cooled Air Conditioner | KITOZER-AC-5kW-220V | 5kW cooling capacity, 220V, temperature control range 18℃~30℃, IP54 industrial grade with dehumidification | 2 | Unit | KITOZER | One for use, one for standby |
| 9 | HFC-227ea Fire Extinguishing Device | KITOZER-FM-20L | 20L, automatic activation, fire extinguishing concentration ≤8%, non-toxic and pollution-free, compatible with 20FT cabinet | 1 | Set | KITOZER | Including smoke/temperature detectors and activator |
| 10 | AC/DC Distribution Cabinet | KITOZER-PD-30kW | DC600V, AC380V, input/output loops, air switches, fuses, lightning arresters, earthing terminals | 1 | Unit | KITOZER | IP54, floor-standing |
| 11 | UPS Power Supply | KITOZER-UPS-1kVA | 1kVA online type, backup time ≥30min, ensures uninterrupted power for BMS/EMS | 1 | Unit | KITOZER | DC220V input |
| 12 | Earthing System | KITOZER-GS-20FT | Earthing resistance ≤4Ω, including earthing electrodes, earthing wires and copper bars | 1 | Set | KITOZER | Anti-corrosion design |
| 13 | Standard Container | KITOZER-20FT-S | 6058mm×2438mm×2591mm, carbon steel, C4 anti-corrosion grade, IP54, sealed doors & windows, lifting lugs, lighting and sockets | 1 | Unit | KITOZER | White/grey optional |
5.2 Medium Version (20FT, 250kWh/100kW, Air/Liquid Cooling Optional)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-51.2V200Ah | Lithium iron phosphate, 51.2V, 200Ah, cycle life ≥6000 times, Grade A cells, operating temperature -30℃~60℃ | 25 | Set | KITOZER | Series-connected to form 512V battery clusters, 2 clusters in parallel |
| 2 | Battery Rack | KITOZER-BR-20FT-12 Layer | Cold-rolled steel, anti-corrosion coating, load capacity ≥800kg/layer, compatible with 20FT cabinet | 2 | Set | KITOZER | Including insulation accessories and fixing bolts |
| 3 | High-voltage Combiner Box | KITOZER-HB-1000V-12 Strings | DC1000V, 12 input channels, 2 output channels, anti-reverse connection, overcurrent protection, insulation monitoring and arc detection | 2 | Unit | KITOZER | IP54, wall-mounted |
| 4 | Power Conversion System (PCS) | KITOZER-PCS-100kW-1000V | Bidirectional DC/AC, 100kW, DC600V~1000V, AC380V±10%, THDi<3%, efficiency ≥96.5% | 1 | Unit | KITOZER | Air/liquid cooling optional, dual grid-connected/off-grid mode |
| 5 | Isolation Transformer | KITOZER-TR-100kVA-380V | 100kVA, three-phase, 380V/380V, isolation voltage ≥2500V, efficiency ≥98.5% | 1 | Unit | KITOZER | Dry type, IP20 |
| 6 | Battery Management System (BMS) | KITOZER-BMS-1000V | Main + slave control, supports 24 module strings, voltage accuracy ±0.3%, temperature accuracy ±0.5℃, SOC accuracy ±2%, full protection and communication redundancy | 1 | Set | KITOZER | Including 1×BCMU, 25×BMU |
| 7 | Energy Management System (EMS) | KITOZER-EMS-100kW | Local monitoring + remote operation & maintenance, supports peak-valley arbitrage, frequency regulation and backup power mode, Modbus/TCP/4G communication, data storage ≥2 years and fault alarm | 1 | Set | KITOZER | Including touch screen, monitoring software and remote module |
| 8 | Temperature Control System | KITOZER-AC-12kW-380V (Air-cooled) / KITOZER-LC-12kW-380V (Liquid-cooled) | Air-cooled: 12kW cooling capacity, 380V, temperature range 20℃~28℃, IP54; Liquid-cooled: 12kW cooling capacity, ethylene glycol circulation, temperature range 22℃~26℃, cell temperature difference ≤2℃ | 2 | Unit | KITOZER | One for use, one for standby |
| 9 | Aerosol Fire Extinguishing Device | KITOZER-AE-30L | 30L, automatic activation, fast fire suppression, no residue, eco-friendly and non-toxic for 20FT cabinets | 1 | Set | KITOZER | Including smoke/temperature detectors and combustible gas sensors |
| 10 | AC/DC Distribution Cabinet | KITOZER-PD-100kW | DC1000V, AC380V, input/output loops, air switches, fuses, lightning arresters, earthing terminals and smart meters | 1 | Unit | KITOZER | IP54, floor-standing |
| 11 | UPS Power Supply | KITOZER-UPS-3kVA | 3kVA online type, backup time ≥60min, ensures uninterrupted power for BMS/EMS | 1 | Unit | KITOZER | DC220V input |
| 12 | Earthing & Lightning Protection System | KITOZER-GS-LS-20FT | Earthing resistance ≤2Ω, including earthing electrodes, copper bars and Class I/II lightning arresters | 1 | Set | KITOZER | Anti-corrosion and surge protection design |
| 13 | Standard Container | KITOZER-20FT-M | 6058mm×2438mm×2591mm, carbon steel, C5 anti-corrosion grade, IP55, sealed doors & windows, lifting lugs, LED lighting, waterproof sockets and emergency lights | 1 | Unit | KITOZER | White/grey optional, customized appearance available |
5.3 Premium Version (40FT, 1MWh/500kW, Liquid-cooled)
è¡¨æ ¼
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Energy Storage Battery Module | KITOZER-LFP-51.2V280Ah | Lithium iron phosphate, 51.2V, 280Ah, cycle life ≥7000 times, Grade A cells, operating temperature -30℃~65℃, high energy density | 72 | Set | KITOZER | Series-connected to form 512V battery clusters, 6 clusters in parallel |
| 2 | Battery Rack | KITOZER-BR-40FT-15 Layer | Hot-dip galvanized + anti-corrosion coated cold-rolled steel, load capacity ≥1000kg/layer, compatible with 40FT cabinet | 6 | Set | KITOZER | Including insulation accessories, fixing bolts and seismic supports |
| 3 | High-voltage Combiner Box | KITOZER-HB-1500V-15 Strings | DC1500V, 15 input channels, 6 output channels, anti-reverse connection, overcurrent protection, insulation monitoring, arc detection and fuse protection | 6 | Unit | KITOZER | IP55, wall-mounted with communication function |
| 4 | Power Conversion System (PCS) | KITOZER-PCS-500kW-1500V | Bidirectional DC/AC, 500kW, DC800V~1500V, AC380V±10%, THDi<1.5%, efficiency ≥97.5%, seamless grid/off-grid switching | 2 | Unit | KITOZER | Liquid-cooled, dual parallel redundant design |
| 5 | Isolation Transformer | KITOZER-TR-500kVA-380V | 500kVA, three-phase, 380V/380V, isolation voltage ≥3000V, efficiency ≥99%, low noise | 2 | Unit | KITOZER | Dry type, IP20, dual machine redundancy |
| 6 | Battery Management System (BMS) | KITOZER-BMS-1500V | Main + slave control, supports 90 module strings, voltage accuracy ±0.2%, temperature accuracy ±0.3℃, SOC accuracy ±1%, full protection and dual communication redundancy | 1 | Set | KITOZER | Including 1×BCMU, 72×BMU |
| 7 | Energy Management System (EMS) | KITOZER-EMS-500kW | Local monitoring + remote operation & maintenance, supports peak-valley arbitrage, frequency regulation, peak shaving, backup power and microgrid modes, Modbus/TCP/4G/5G communication, data storage ≥5 years, intelligent scheduling and fault diagnosis | 1 | Set | KITOZER | Including touch screen, monitoring software, remote module and dispatching interface |
| 8 | Liquid Cooling Temperature Control System | KITOZER-LC-30kW-380V | 30kW cooling capacity, ethylene glycol circulation, temperature range 22℃~25℃, cell temperature difference ≤1℃, 35% lower energy consumption than air cooling, IP55 | 4 | Unit | KITOZER | Two for use, two for standby, redundant design |
| 9 | HFC-227ea + Aerosol Composite Fire Extinguishing Device | KITOZER-FM-AE-50L | 50L composite fire suppression, automatic/manual activation, high fire extinguishing efficiency, no residue, eco-friendly for 40FT cabinets | 2 | Set | KITOZER | Including smoke/temperature detectors, combustible gas sensors and sound-light alarms |
| 10 | AC/DC Distribution Cabinet | KITOZER-PD-500kW | DC1500V, AC380V, input/output loops, air switches, fuses, lightning arresters, earthing terminals, smart meters and harmonic governance | 2 | Unit | KITOZER | IP55, floor-standing, dual machine redundancy |
| 11 | UPS Power Supply | KITOZER-UPS-10kVA | 10kVA online type, backup time ≥120min, ensures uninterrupted power for BMS/EMS, dual machine redundancy | 2 | Unit | KITOZER | DC220V input |
| 12 | Earthing & Lightning Protection System | KITOZER-GS-LS-40FT | Earthing resistance ≤1Ω, including earthing electrodes, copper bars and Class I/II/III lightning arresters and surge protectors | 1 | Set | KITOZER | Anti-corrosion full-link surge protection design |
| 13 | Standard Container | KITOZER-40FT-L | 12192mm×2438mm×2591mm, carbon steel, C5+ anti-corrosion grade, IP55, sealed doors & windows, lifting lugs, LED lighting, waterproof sockets, emergency lights, access control and video surveillance | 1 | Unit | KITOZER | White/grey optional, customized appearance and LOGO available |
6. Full Product Technical Parameters
6.1 Energy Storage Battery Module (KITOZER-LFP Series)
- Cell Type: Lithium Iron Phosphate (LiFePO4), Grade A, cobalt-free, high safety
- Rated Voltage: 51.2V (16 cells in series, 3.2V per cell)
- Rated Capacity: 100Ah/200Ah/280Ah optional
- Energy Density: ≥140Wh/kg (100Ah), ≥150Wh/kg (200Ah), ≥160Wh/kg (280Ah)
- Cycle Life: ≥5000 cycles (Basic), ≥6000 cycles (Medium), ≥7000 cycles (Premium), @80% DOD, 25℃
- Operating Temperature: -20℃~60℃ (Basic), -30℃~60℃ (Medium), -30℃~65℃ (Premium)
- Protection Rating: IP67 for modules, dustproof and waterproof
- Recommended SOC Range: 10%~90%, supports 0%~100%
- SOH Range: 0%~100%, accuracy ±2%
6.2 Power Conversion System (PCS, KITOZER-PCS Series)
- Topology: Bidirectional DC/AC, two-level / three-level optional
- Rated Power: 30kW/100kW/500kW optional
- DC Voltage Range: 400V~600V (Basic), 600V~1000V (Medium), 800V~1500V (Premium)
- AC Voltage: 380V±10%, three-phase five-wire, 50Hz±0.5Hz
- Conversion Efficiency: ≥95% (Basic), ≥96.5% (Medium), ≥97.5% (Premium)
- THDi: <5% (Basic), <3% (Medium), <1.5% (Premium)
- Power Factor: 0.99 (adjustable leading/lagging)
- Response Time: ≤500ms (Basic), ≤300ms (Medium), ≤200ms (Premium)
- Operating Modes: Grid-connected charge/discharge, off-grid independent power supply, seamless grid/off-grid switching
- Protection Rating: IP54 (Basic/Medium), IP55 (Premium)
6.3 Battery Management System (BMS, KITOZER-BMS Series)
- Architecture: Master (BCMU) + Slave (BMU) distributed collection
- Collection Accuracy: Voltage ±0.5% (Basic)/±0.2% (Premium), Temperature ±1℃ (Basic)/±0.3℃ (Premium), Current ±1%
- SOC Accuracy: ±3% (Basic), ±2% (Medium), ±1% (Premium)
- SOH Accuracy: ±5% (Basic), ±3% (Medium), ±2% (Premium)
- Protection Functions: Overvoltage, undervoltage, overcurrent, short circuit, overtemperature, low temperature, electric leakage, insulation fault and communication fault protection
- Communication Interfaces: Modbus-RTU (Basic), Modbus-TCP/4G (Medium), Modbus-TCP/5G dual redundancy (Premium)
- Operating Temperature: -20℃~60℃, Protection Rating IP54
6.4 Energy Management System (EMS, KITOZER-EMS Series)
- Monitoring Functions: Full-link data collection and monitoring of batteries, PCS, temperature control, fire protection and power distribution
- Control Strategies: Peak-valley arbitrage, frequency regulation, peak shaving, backup power and microgrid coordinated intelligent charge-discharge optimization
- Data Storage: ≥1 year (Basic), ≥2 years (Medium), ≥5 years (Premium), data export supported
- Communication Interfaces: Modbus-TCP, 4G/5G, Ethernet, remote monitoring & operation & maintenance supported
- Display Interface: 7-inch touch screen (Basic), 10-inch touch screen (Medium), 15-inch touch screen (Premium), Chinese & English bilingual
- Fault Alarm: Sound-light alarm, SMS/APP push (Medium & Premium), fault log recording
6.5 Temperature Control System (Air-cooled / Liquid-cooled, KITOZER Series)
6.5.1 Air-cooled Air Conditioner
- Cooling Capacity: 5kW (Basic), 12kW (Medium)
- Power Supply: 220V (Basic), 380V (Medium), 50Hz
- Temperature Control Range: 18℃~30℃ (Basic), 20℃~28℃ (Medium)
- Protection Rating: IP54 industrial grade with dehumidification, dustproof and anti-corrosion functions
6.5.2 Liquid Cooling Unit
- Cooling Capacity: 12kW (Medium), 30kW (Premium)
- Cooling Medium: 40% concentration ethylene glycol aqueous solution, anti-freezing and anti-corrosion
- Temperature Control Range: 22℃~26℃ (Medium), 22℃~25℃ (Premium)
- Cell Temperature Difference: ≤2℃ (Medium), ≤1℃ (Premium)
- Energy Consumption: 30%~35% lower than air cooling, Protection Rating IP55
6.6 Fire Protection System (KITOZER Series)
6.6.1 HFC-227ea Fire Extinguishing Device
- Fire Extinguishing Agent: HFC-227ea, clean, eco-friendly and non-toxic
- Fire Extinguishing Concentration: ≤8%, fire suppression time ≤10s
- Activation Modes: Automatic (smoke + temperature linkage), manual, emergency startup
- Protection Scope: Full cabin protection for 20FT/40FT containers
6.6.2 Aerosol Fire Extinguishing Device
- Fire Extinguishing Agent: Hot aerosol, solid storage, high safety
- Fire Extinguishing Efficiency: Fast suppression, no residue, no equipment pollution
- Activation Modes: Automatic & manual, suitable for narrow space protection
6.7 Cabinet Structure (KITOZER Series)
- Material: Q235 carbon steel, hot-dip galvanized + anti-corrosion coating
- Anti-corrosion Grade: C4 (Basic), C5 (Medium), C5+ (Premium), suitable for coastal, high-humidity and high salt-fog environments
- Protection Rating: IP54 (Basic), IP55 (Medium & Premium), dustproof, waterproof and moisture-proof
- Dimensions: 20FT (6058mm×2438mm×2591mm), 40FT (12192mm×2438mm×2591mm)
- Earthquake Resistance Grade: Grade 8; Wind Resistance Grade: Grade 12
7. Full Product Application Scope
7.1 Grid-side Applications
- Grid Peak Shaving: Charge during off-peak hours at night and discharge during daytime peak hours to balance grid load and ease power supply pressure
- Grid Frequency Regulation: Rapidly respond to grid frequency fluctuations to provide primary & secondary frequency regulation services and guarantee grid stability
- Voltage Regulation: Dynamic reactive power compensation to stabilize grid voltage and improve power quality
- Backup Power: Fast switching upon grid faults to guarantee power supply for critical loads and enhance grid reliability
7.2 User-side Applications
- Industrial & Commercial Peak-Valley Arbitrage: Utilize peak-valley electricity price difference to charge at off-peak and discharge at peak to cut power costs
- Demand Management: Reduce peak power demand to lower basic electricity expenses
- Backup Power: For factories, hospitals, data centers and office buildings to maintain continuous power supply during power outages
- Power Quality Governance: Suppress harmonics, balance three-phase loads and compensate reactive power to ensure stable equipment operation
7.3 New Energy Supporting Applications
- PV Power Station Matching: Smooth PV output fluctuations, boost PV consumption capacity and guarantee grid-connected stability
- Wind Farm Matching: Restrain randomness and volatility of wind power, improve wind power grid-connected quality and reduce wind & solar curtailment
- Wind-Solar-Storage Integration: Coordinated operation of PV, wind power and energy storage to form a stable power supply system and lift new energy utilization rate
7.4 Microgrid & Off-grid Applications
- Power Supply for Remote Areas: Power-free villages, isolated islands, pastoral areas and mining areas, forming microgrids with PV/wind power/diesel generators for independent power supply
- Island & Border Defense Power Supply: Stable green power for islands and border posts to cut diesel consumption
- Mobile Microgrid: Rapidly deployable mobile energy storage containers for construction sites, events and emergency rescue temporary power supply
7.5 Other Applications
- Charging Pile Supporting: Alleviate peak power pressure of charging piles, improve charging pile utilization and reduce grid expansion costs
- Data Center Energy Storage: Backup power + peak-valley arbitrage to guarantee safe power supply for data centers and cut operating costs
- Emergency Energy Storage: Provide emergency power supply during natural disasters and grid faults to secure livelihood and rescue equipment operation
8. Full Product Advantages
8.1 Core Functional Features
- High Integration & Rapid Deployment: Integrated prefabricated design in factory, only hoisting and wiring required on-site for commissioning, cutting deployment cycle by 80%, no civil construction needed for various outdoor sites
- High Safety & Reliability: Grade A cobalt-free lithium iron phosphate cells with high safety; full-link BMS protection against overvoltage, undervoltage, overcurrent, short circuit and overtemperature; HFC-227ea/aerosol composite fire suppression with full-link fire early warning; IP54/IP55 protection and C4/C5+ anti-corrosion grade for stable operation under -30℃~55℃ extreme environments
- High Efficiency & Long Service Life: Premium liquid cooling design with cell temperature difference ≤1℃ and cycle life ≥7000 times; PCS conversion efficiency ≥97.5% and THDi<1.5% for low energy consumption; EMS intelligent charge-discharge optimization to boost system efficiency and battery lifespan
- Intelligent Operation & Maintenance with Remote Control: Dual BMS+EMS intelligent monitoring for full-link real-time data collection; support 4G/5G remote monitoring, fault alarm, parameter configuration and remote upgrade; data storage up to 5 years with traceable fault logs to cut operation & maintenance costs
- Flexible Capacity Expansion for Multiple Scenarios: Modular design supporting parallel expansion of multiple containers with flexible capacity expansion from 50kWh to 5MWh; compatible with grid-side, user-side, new energy supporting and microgrid scenarios with customizable capacity and power
8.2 Customization & OEM/ODM Advantages
- Full-process Customization Service: Customizable cabinet size, capacity, power, color, LOGO, interface type and communication protocol to match different project requirements
- OEM/ODM Processing: One-stop service including brand OEM, scheme design, technical support and manufacturing, confidential production to protect customer intellectual property
- Technical Confidentiality Agreement: Sign confidentiality contracts to strictly protect core customer data including schemes, parameters and drawings from information leakage
- Fast Custom Delivery: Standardized modular production with 15~30 days delivery for regular customization, priority scheduling for urgent orders
8.3 Spot & Supply Chain Advantages
- Mass Spot Inventory: Regular Basic & Medium models in stock, 50kWh~300kWh air-cooled containers available for direct spot delivery within 7 days for urgent projects
- Stable Supply Chain: Long-term strategic cooperation with first-tier brands for core cells, PCS and BMS, guaranteed raw material quality and stable supply without stockout risks
- Large-scale Production: Modern production workshop with automated production lines, annual output over 1,000 energy storage containers, controllable costs and high cost performance
8.4 Technical Parameter Advantages (Core Tender-winning Indicators)
- Cell Cycle Life: ≥5000 (Basic), ≥6000 (Medium), ≥7000 (Premium), industry-leading
- PCS Conversion Efficiency: ≥95% (Basic), ≥97.5% (Premium), high energy efficiency
- Cell Temperature Difference: ≤2℃ (Medium liquid-cooled), ≤1℃ (Premium liquid-cooled), guaranteeing battery consistency and extending service life
- BMS SOC Accuracy: ±3% (Basic), ±1% (Premium), precise battery status control
- Protection Rating: IP54 (Basic), IP55 (Medium & Premium), dustproof and waterproof for harsh environments
- Anti-corrosion Grade: C4 (Basic), C5+ (Premium), long-term rust-free operation in coastal and high-humidity areas
9. Full Product Tender-winning Parameters (★ Marked Core Indicators)
9.1 Energy Storage Battery Module
★ Cell Type: Lithium Iron Phosphate (LiFePO4), Grade A, cobalt-free ★ Rated Capacity: 100Ah/200Ah/280Ah optional ★ Cycle Life: ≥5000 (Basic), ≥6000 (Medium), ≥7000 (Premium) @80% DOD, 25℃ ★ Operating Temperature: -20℃~60℃ (Basic), -30℃~65℃ (Premium) ★ Protection Rating: IP67
9.2 Power Conversion System (PCS)
★ Rated Power: 30kW/100kW/500kW optional ★ DC Voltage Range: 400V~600V (Basic), 800V~1500V (Premium) ★ Conversion Efficiency: ≥95% (Basic), ≥97.5% (Premium) ★ THDi: <5% (Basic), <1.5% (Premium) ★ Response Time: ≤500ms (Basic), ≤200ms (Premium) ★ Operating Mode: Seamless grid-connected/off-grid switching
9.3 Battery Management System (BMS)
★ Architecture: Master + slave distributed collection ★ SOC Accuracy: ±3% (Basic), ±1% (Premium) ★ Protection Functions: Multiple protections including overvoltage, undervoltage, overcurrent, short circuit and overtemperature ★ Communication Interface: Modbus-TCP/5G dual redundancy (Premium)
9.4 Energy Management System (EMS)
★ Control Strategies: Peak-valley arbitrage, frequency regulation, peak shaving and microgrid coordination ★ Data Storage: ≥1 year (Basic), ≥5 years (Premium) ★ Remote Monitoring: Support 4G/5G remote operation & maintenance and fault alarm
9.5 Temperature Control System
★ Cooling Modes: Air-cooled / Liquid-cooled optional ★ Cell Temperature Difference: ≤2℃ (Medium liquid-cooled), ≤1℃ (Premium liquid-cooled) ★ Energy Consumption: 30%~35% lower than air cooling (liquid-cooled)
9.6 Cabinet Structure
★ Dimensions: 20FT/40FT standard containers ★ Protection Rating: IP54 (Basic), IP55 (Medium & Premium) ★ Anti-corrosion Grade: C4 (Basic), C5+ (Premium) ★ Earthquake & Wind Resistance: Grade 8 earthquake resistance, Grade 12 wind resistance
9.7 Fire Protection System
★ Fire Extinguishing Device: HFC-227ea / aerosol composite fire suppression ★ Activation Modes: Automatic / manual / emergency startup ★ Protection Scope: Full cabin protection compatible with 20FT/40FT cabinets
10. Full Product Solutions
10.1 Grid-side Energy Storage Solution
For grid peak shaving, frequency regulation, voltage regulation and backup power demands, medium & large liquid-cooled energy storage containers (1MWh~5MWh/500kW~2.5MW) are adopted, with multiple units connected in parallel to form energy storage power stations. Featuring fast response speed ≤200ms, high stability and long service life, the EMS system docks with grid dispatching platforms to automatically execute charge-discharge instructions, realizing grid load balance, frequency stabilization and voltage regulation, lifting new energy grid consumption capacity and securing stable grid operation.
10.2 Industrial & Commercial Energy Storage Solution
For industrial & commercial peak-valley arbitrage, demand management and backup power demands, small & medium air-cooled energy storage containers (50kWh~250kWh/30kW~100kW) are adopted with flexible deployment, low cost and easy maintenance. The EMS system embeds peak-valley electricity price strategies to automatically charge at off-peak and discharge at peak for power cost reduction; it supports demand control to cut peak power load and seamlessly switch to off-grid mode upon power failure to sustain power supply for critical equipment.
10.3 New Energy Supporting Energy Storage Solution
To address PV/wind farm output fluctuations and wind & solar curtailment, medium & large energy storage containers (250kWh~5MWh/100kW~2.5MW) are matched with PV/wind inverters to smooth output fluctuations and boost new energy consumption capacity. The EMS system realizes coordinated wind-solar-storage control, optimizing energy storage charge-discharge strategies based on PV/wind output, grid load and electricity price data to reduce wind & solar curtailment and raise project revenue.
10.4 Microgrid Energy Storage Solution
For power-free/weak-grid remote areas, islands and border posts, small & medium energy storage containers (50kWh~250kWh/30kW~100kW) form microgrids with PV modules, wind turbines and diesel generators. The EMS system realizes multi-energy coordinated dispatching, prioritizing PV/wind power, with energy storage for peak shaving and valley filling and diesel generators as backup, guaranteeing stable power supply for microgrid loads, cutting diesel consumption and realizing green low-carbon power supply.
10.5 Mobile Energy Storage Solution
For emergency power supply, construction site temporary power and event support scenarios, small energy storage containers (50kWh~100kWh/30kW~50kW) with trailer/lifting structures support rapid relocation and deployment. Equipped with independent off-grid power supply function to output 380V AC power for all types of loads, it supports fast charge-discharge and rapid emergency response to meet temporary power supply demands.
11. Full Product Application Cases
11.1 Industrial & Commercial Park Energy Storage Project in Guangdong
- Project Scale: 1×20FT Medium energy storage container, 250kWh/100kW
- Application Scenario: Peak-valley arbitrage + backup power
- Project Effect: Charging during off-peak hours (23:00-7:00) and discharging during peak hours (8:00-22:00), saving approximately RMB 200,000 in electricity fees annually; seamless switching upon grid power failure to sustain power supply for park critical equipment and boost power supply reliability
11.2 Wind Farm Supporting Energy Storage Project in Inner Mongolia
- Project Scale: 5×40FT Premium energy storage containers, total 5MWh/2.5MW
- Application Scenario: Wind power consumption + output smoothing
- Project Effect: Smooth wind power output fluctuations, reduce wind curtailment rate by 30%; improve wind power grid-connected quality to meet grid connection requirements; increase annual power generation by about 5 million kWh and lift project revenue
11.3 Island Microgrid Project in Hainan
- Project Scale: 2×20FT Basic energy storage containers, total 100kWh/60kW
- Application Scenario: Off-grid microgrid, coordinated power supply of PV + energy storage + diesel generator
- Project Effect: Guarantee stable power supply for island residents’ living and production, replace traditional diesel power generation, save about 100 tons of diesel annually and cut carbon emissions by 300 tons; lift power supply stability with voltage fluctuation ≤±2% to meet daily power demand
11.4 Grid Frequency Regulation Energy Storage Project in Jiangsu
- Project Scale: 10×40FT Premium energy storage containers, total 10MWh/5MW
- Application Scenario: Primary & secondary grid frequency regulation
- Project Effect: Rapidly respond to grid frequency fluctuations with response time ≤200ms and frequency regulation accuracy ≥99%; stabilize grid frequency and cut grid frequency regulation costs; lift grid new energy consumption capacity to support energy structure transformation
11.5 Data Center Backup Energy Storage Project in Shenzhen
- Project Scale: 3×20FT Medium energy storage containers, total 750kWh/300kW
- Application Scenario: Backup power + peak-valley arbitrage
- Project Effect: Switch within ≤100ms upon grid power failure to sustain power supply for data center servers and network equipment and avoid data loss; save approximately RMB 500,000 in electricity fees annually via peak-valley arbitrage to cut operating costs
12. Full Product Faults & Maintenance
12.1 Common Faults & Troubleshooting
12.1.1 Battery System Faults
- Phenomenon: Cell overvoltage/undervoltage, overtemperature, excessive temperature difference, rapid capacity attenuation
- Root Causes: Abnormal BMS parameters, cell aging, poor heat dissipation, unreasonable charge-discharge strategies
- Solutions: Check BMS data remotely and calibrate parameters; inspect temperature control systems and clean filter screens to ensure heat dissipation; replace aged cells; optimize EMS charge-discharge strategies to avoid overcharging and overdischarging
12.1.2 PCS Faults
- Phenomenon: PCS fails to start, grid connection failure, abnormal output voltage, excessive harmonics, overheating alarm
- Root Causes: Abnormal input voltage, communication faults, poor heat dissipation, module damage, incorrect parameter settings
- Solutions: Inspect AC/DC input voltage and eliminate circuit faults; check communication wiring and restart communication modules; clean heat dissipation air ducts and inspect fan/air conditioner operation; test PCS modules and replace damaged parts; calibrate PCS parameters and re-grid connect
12.1.3 BMS/EMS Faults
- Phenomenon: Abnormal data collection, communication interruption, false fault alarms, failed remote monitoring
- Root Causes: Damaged sensors, loose wiring, faulty communication modules, software anomalies, network interruption
- Solutions: Inspect sensors and replace damaged components; fasten wiring terminals and eliminate circuit faults; restart communication modules and check network connections; upgrade software versions to repair system vulnerabilities; restore network and restart remote monitoring
12.1.4 Temperature Control System Faults
- Phenomenon: Excessively high/low cabin temperature, excessive temperature difference, air conditioner/liquid cooling unit fails to start, poor cooling effect
- Root Causes: Damaged temperature sensors, blocked filter screens, faulty fans/compressors, refrigerant leakage, abnormal power supply
- Solutions: Calibrate and replace damaged temperature sensors; clean filter screens and air ducts to remove dust and debris; inspect fan/compressor operation and replace damaged parts; test refrigerant pressure and refill refrigerant; check power wiring to eliminate power supply faults
12.1.5 Fire Protection System Faults
- Phenomenon: False smoke/temperature sensor alarms, fire extinguishing device fails to activate, failed sound-light alarm
- Root Causes: Contaminated sensors, loose wiring, faulty starters, abnormal power supply
- Solutions: Clean sensor probes to remove dust and debris; fasten wiring terminals and eliminate circuit faults; test starters and replace damaged components; inspect fire protection power supply to guarantee normal power supply
12.2 Daily Maintenance Schedule
12.2.1 Daily Inspection (Remote + On-site)
- Remote Monitoring: View BMS, EMS and PCS data, monitor cell voltage, temperature, SOC, SOH, cabin temperature & humidity and check for fault alarms
- On-site Inspection: Check container appearance for deformation, corrosion and damage; verify good sealing of doors & windows; inspect abnormal noise, odor and overheating of temperature control, fire protection and power distribution equipment; confirm normal indicator light status
12.2.2 Weekly Maintenance
- Cleaning: Clean container exterior, heat dissipation filter screens and air conditioner air outlets to remove dust and debris for unobstructed heat dissipation
- Fastening: Inspect all wiring terminals and bolts, fasten loose parts to prevent poor contact
- Testing: Test smoke/temperature sensor sensitivity and sound-light alarm function of fire protection systems; test emergency lighting and UPS switching function
12.2.3 Monthly Maintenance
- Calibration: Calibrate BMS voltage & temperature sensors and SOC accuracy; calibrate EMS time and parameters; calibrate PCS output voltage and frequency
- Lubrication: Add lubricant to rotating parts including fans and motors to reduce wear
- Data Backup: Back up BMS, EMS and PCS operating data and parameter configurations to prevent data loss
12.2.4 Quarterly Maintenance
- Performance Test: Test battery module capacity and internal resistance to evaluate battery health status; test PCS conversion efficiency, THDi and response time; test cooling/heating effect of temperature control systems and cell temperature difference
- Software Upgrade: Upgrade BMS, EMS and PCS software versions to repair vulnerabilities and optimize performance
- Earthing Test: Test earthing system resistance to ensure ≤4Ω (Basic)/≤1Ω (Premium) for reliable earthing
12.2.5 Annual Maintenance
- Comprehensive Overhaul: Disassemble and inspect internal parts of battery racks, combiner boxes and distribution cabinets, clean dust and replace aged components
- Cell Inspection: Test capacity, internal resistance and cycle life of all cells, replace severely attenuated cells
- Anti-corrosion Treatment: Derust and repaint corroded parts of container exterior to extend service life
- Fire Protection Inspection: Fully test fire extinguishing device pressure and agent validity, replace expired fire extinguishing agents
12.3 Maintenance Precautions
- Safety Priority: Maintenance operations must be performed by certified professional personnel in strict compliance with electrical safety regulations; cut off power supply and hang warning signs before operation; wear insulating protective equipment for high-voltage area operations
- Environmental Protection: Avoid maintenance in rainy, high-temperature and humid environments; prevent water from entering equipment interior during cleaning to avoid short circuits
- Spare Parts Management: Stock common spare parts (sensors, fuses, filter screens, communication modules) for rapid replacement upon faults
- Traceable Records: Record all maintenance and fault handling details including time, personnel, content and results to establish equipment maintenance archives for traceability and analysis
13. Factory Strength & After-sales Service
13.1 Factory Strength
KITOZER is a leading domestic integrated enterprise focusing on R&D, production and sales of energy storage equipment, specializing in outdoor energy storage containers, cabinets, UPS power supplies and other energy storage devices. It owns a modern production base, professional R&D team, advanced production equipment and complete quality control system.
- Production Base: Covering 50,000㎡ with 30,000㎡ standardized workshops and 10 automated production lines, annual output over 1,000 energy storage containers with large-scale production for controllable costs
- R&D Team: Over 50 core R&D personnel with more than 10 years of energy storage industry experience, full-link R&D capacity covering batteries, BMS, PCS, EMS and structural design; independent intellectual property rights with over 50 patents for continuous technological innovation
- Production Equipment: Introduced laser cutting machines, CNC bending machines, automated welding robots, spraying production lines, battery testing equipment and system integrated test platforms for full-process automated production with high precision and stable quality
- Quality Control: Strictly comply with ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System; 100% raw material inspection, full-process production quality control and 100% system testing before delivery to ensure qualified products
- Supply Chain Advantages: Long-term strategic cooperation with first-tier brands including CATL, BYD, Sungrow and Huawei, original supply of core components with guaranteed quality and stable supply
13.2 After-sales Service System
KITOZER has established a nationwide, fast-response and professional after-sales service system adhering to the tenet “Customer First, Service Foremost”, providing full-lifecycle services for customers.
- Service Network: 25 offices/service centers nationwide covering North, East, South, Southwest and Northwest China; over 200 certified professional after-sales engineers on standby 24/7 for rapid customer demand response
- Warranty Commitment: 5-year full machine warranty, 8-year battery module warranty (cycle life ≥5000 times); free repair and component replacement for non-artificial damage within warranty period with free on-site service
- Fast Response: Remote troubleshooting and solution provision within 1 hour upon customer fault report; on-site arrival within 24 hours (48 hours for remote areas) for on-site repair and commissioning to quickly restore system operation
- Remote Operation & Maintenance Service: 7×24-hour remote monitoring, fault early warning, remote diagnosis and remote upgrade services; real-time system operation status monitoring to detect potential faults in advance, reduce downtime
- Technical Training Service: Free online + offline training for customers on operation, maintenance and fault handling; training content includes system principles, operation procedures, daily maintenance and common fault troubleshooting to help customers cultivate professional operation & maintenance personnel
- Spare Parts Supply Service: National spare parts warehouse with common spare parts (sensors, fuses, filter screens, communication modules, BMS/PCS components) in stock; spare parts delivery within 48 hours (72 hours for remote areas) for rapid fault repair
- Lifelong Maintenance Service: Preferential lifelong maintenance services outside warranty period, free technical consultation and remote support; only component cost charged for on-site repair with no labor fees; regular return visits with system inspection and maintenance suggestions to guarantee long-term stable system operation
14. Conclusion
With core advantages of high integration, high safety, high efficiency & energy saving, intelligent operation & maintenance and flexible capacity expansion, KITOZER outdoor energy storage containers fully meet multi-scenario energy storage demands including grid-side, user-side, new energy supporting and microgrid applications, providing standardized, customized and cost-effective energy storage solutions for customers. Relying on strong R&D strength, large-scale production capacity, complete quality control system and professional after-sales service system, KITOZER commits to energy storage technological innovation and industrial development, supports the realization of the “Dual Carbon” goals and contributes to the transformation and upgrading of the global energy structure. In the future, KITOZER will continue to deepen its layout in the energy storage sector, continuously optimize product performance, upgrade service quality, create greater value for customers and strive to become a leading global energy storage equipment brand.
15. SEO Optimization (Keywords, Tag System & Anchor Text)
15.1 Search Keywords
Core Primary Keywords
Outdoor Energy Storage Container, Energy Storage Container, KITOZER Energy Storage Container, Energy Storage System, Outdoor Energy Storage System
High-conversion Long-tail Keywords
20FT Outdoor Energy Storage Container, 40FT Energy Storage Container, Industrial & Commercial Energy Storage Container, Grid-side Energy Storage Container, Liquid-cooled Energy Storage Container, Air-cooled Energy Storage Container, 50kWh Energy Storage Container, 1MWh Energy Storage Container, Energy Storage Container Solution, Energy Storage Container Configuration List
Industry Traffic Keywords
Energy Storage Equipment, Battery Energy Storage System, Power Conversion System (PCS), Battery Management System (BMS), Energy Management System (EMS), New Energy Storage, Wind-Solar-Storage Integration, Microgrid Energy Storage, Emergency Energy Storage, Peak-Valley Arbitrage Energy Storage
Brand Exclusive Keywords
KITOZER Outdoor Energy Storage Container, KITOZER Energy Storage System, KITOZER PCS, KITOZER BMS, KITOZER EMS, KITOZER Custom Energy Storage, KITOZER Energy Storage OEM/ODM
Drop-down & Related Search Keywords
Energy Storage Container Price, Energy Storage Container Manufacturer, Energy Storage Container Brand, Energy Storage Container Maintenance, Energy Storage Container Application Cases, Energy Storage Container Technical Parameters, Energy Storage Container Tender-winning Parameters, Energy Storage Container OEM/ODM
15.2 SEO Optimization Tag System
Core Page Optimization Tags
Outdoor Energy Storage Container Solution, KITOZER Energy Storage Container, Energy Storage System Configuration List, Energy Storage Container Technical Parameters, Energy Storage Container Application Cases
Title Tag
KITOZER Outdoor Energy Storage Container Solution | Industrial & Commercial / Grid-side Energy Storage System | Custom Manufacturer
Meta Keywords Tag
Outdoor energy storage container, energy storage container, KITOZER energy storage container, industrial & commercial energy storage, grid-side energy storage, energy storage system, energy storage solution
Meta Description Tag
KITOZER outdoor energy storage container manufacturer supplies 20FT/40FT air/liquid cooling energy storage containers for industrial & commercial peak-valley arbitrage, grid peak shaving & frequency regulation, new energy supporting and microgrid scenarios. Customization and OEM/ODM processing available with high safety, long service life and intelligent operation & maintenance. Welcome inquiries.
H1 Tag
KITOZER Outdoor Energy Storage Container Solution
H2 Tags
System Overview, System Composition, System Classification, System Schematic Diagram, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Tender-winning Parameters, Product Solutions, Application Cases, Faults & Maintenance, Factory Strength & After-sales Service, Conclusion
Internal Link Optimization Tags (Natural Embedded Anchor Text)
Core Anchor Text
Outdoor Energy Storage Container, Energy Storage Container, KITOZER Energy Storage Container, Energy Storage System
Long-tail Anchor Text
20FT Energy Storage Container, Liquid-cooled Energy Storage Container, Industrial & Commercial Energy Storage Solution, Grid-side Energy Storage System, Energy Storage Container Configuration List, Energy Storage Container Technical Parameters
Associated Anchor Text
Power Conversion System (PCS), Battery Management System (BMS), Energy Management System (EMS), New Energy Storage, Microgrid Energy Storage, Energy Storage Equipment Manufacturer